431 research outputs found

    Imaging features of fibrolamellar hepatocellular carcinoma in gadoxetic acid-enhanced MRI

    Get PDF
    Background: Fibrolamellar hepatocellular carcinoma (FLC) is a rare malignancy occurring in young patients without cirrhosis. Objectives of our study were to analyze contrast material uptake in hepatobiliary phase imaging (HBP) in gadoxetic acid-enhanced liver MRI in patients with FLC and to characterize imaging features in sequence techniques other than HBP. Methods: In this retrospective study on histology-proven FLC, contrast material uptake in HBP was quantitatively assessed by calculating the corrected FLC enhancement index (CEI) using mean signal intensities of FLC and lumbar muscle on pre-contrast imaging and HBP, respectively. Moreover, enhancement patterns in dynamic contrast-enhanced MRI and relative signal intensities compared with background liver parenchyma were determined by two radiologists in consensus for HBP, diffusion-weighted imaging using high b-values (DWI), and T2 and T1 weighted pre-contrast imaging. Results: In 6 of 13 patients with FLC gadoxetic acid-enhanced liver MRI was available. The CEI suggested presence of HBP contrast material uptake in all FLCs. A mean CEI of 1.35 indicated FLC signal increase of 35% in HBP compared with pre-contrast imaging. All FLCs were hypointense in HBP compared with background liver parenchyma. Three of 6 FLCs had arterial hyperenhancement and venous wash-out. In DWI and T2 weighted imaging, 5 of 6 FLCs were hyperintense. In T1 weighted imaging, 5 of 6 FLCs were hypointense. Conclusion: Hepatobiliary uptake of gadoxetic acid was quantitatively measurable in all FLCs investigated in our study. The observation of hypointensity of FLCs in HBP compared with background liver parenchyma emphasizes the role of gadoxetic acid-enhanced liver MRI for non-invasive diagnosis of FLC and its importance in the diagnostic work-up of indeterminate liver lesions

    A phase II study for metabolic in vivo response monitoring with sequential 18FDG-PET-CT during treatment with the EGFR-monoclonal-antibody cetuximab in metastatic colorectal cancer: the Heidelberg REMOTUX trial

    Get PDF
    BACKGROUND: The epidermal growth factor receptor monoclonal antibody cetuximab has proven activity in metastatic colorectal cancer. To date, the mechanisms of action are not completely understood. Especially the impact on tumor glucose metabolism, or tumor vascularization remains largely unclear. The understanding of mechanisms such as early changes in tumor metabolism is of clinical importance since there may be a substantial influence on choice and sequence of drug combinations. Early signals of response to cetuximab may prove useful to identify patients having a relevant clinical treatment benefit. The objective of this trial is to evaluate the predictive relevance of the relative change in (18 )F-Fluorodeoxyglucose tumor uptake for early clinical response during short-term single agent treatment with cetuximab. Early clinical response will be routinely measured according to the response evaluation criteria in solid tumors. Accompanying research includes cytokine immune monitoring and analysis of tumor proteins and tumor genes. METHODS/DESIGN: The REMOTUX trial is an investigator-initiated, prospective, open-label, single-arm, single-center early exploratory predictive study. The first (18 )F-FDG PET-CT is conducted at baseline followed by the run-in phase with cetuximab at days 1 and 8. At day 14, the second (18 )F-FDG PET-CT is performed. Subsequently, patients are treated according to the Folfiri-cetuximab regimen as an active and approved first-line regimen for metastatic colorectal carcinoma. At day 56, clinical response is evaluated with a CT-scan compared to the baseline analysis. Tracer uptake is assessed using standardized uptake values (SUVs). The main hypothesis to be tested in the primary analysis is whether or not the relative change in the SUV from baseline to day 14 has any predictive relevance for early clinical response determined at day 56. Patients are followed until death from any cause or until 24 months after the last patient has ended trial treatment. DISCUSSION: The aim of this trial is to evaluate metabolic changes in metastatic colorectal cancer during short-term single agent treatment with cetuximab and to analyse their potential of predicting early clinical response. This could be helpful to answer the question if early identification of patients not responding to cetuximab is possible. TRIAL REGISTRATION: ClinicalTrials.gov NCT200811021020; EudraCT 20090132792

    Is MRCP necessary to diagnose pancreas divisum?

    Get PDF
    Background: The purpose of this study is to compare the performance of three-dimensional magnetic resonance cholangiopancreatography (3D-MRCP) with non-MRCP T2-weighted magnetic resonance imaging (MRI) sequences for diagnosis of pancreas divisum (PD). Methods: This is a retrospective study of 342 consecutive patients with abdominal MRI including 3D-MRCP. 3D-MRCP was a coronal respiration-navigated T2-weighted sequence with 1.5 mm slice thickness. Non-MRCP T2-weighted sequences were (1) a coronal inversion recovery sequence (TIRM) with 6 mm slice thickness and (2) a transverse single shot turbo spin echo sequence (HASTE) with 4 mm slice thickness. For 3D-MRCP, TIRM, and HASTE, presence of PD and assessment of evaluability were determined in a randomized manner. A consensus read by two radiologists using 3D-MRCP, non-MRCP T2-weighted sequences, and other available imaging sequences served as reference standard for diagnosis of PD. Statistical analysis included performance analysis of 3D-MRCP, TIRM, and HASTE and testing for noninferiority of non-MRCP T2-weighted sequences compared with 3D-MRCP. Results: Thirty-three of 342 patients (9.7%) were diagnosed with PD using the reference standard. Sensitivity/specificity of 3D-MRCP for detecting PD were 81.2%/69.7% (p < 0.001). Sensitivity/specificity of TIRM and HASTE were 92.5%/93.9 and 98.1%/97.0%, respectively (p < 0.001 each). Grouped sensitivity/specificity of non-MRCP T2-weighted sequences were 99.8%/91.0%. Non-MRCP T2-weighted sequences were non-inferior to 3D-MRCP alone for diagnosis of PD. 20.2, 7.3%, and 2.3% of 3D-MRCP, TIRM, and HASTE, respectively, were not evaluable due to motion artifacts or insufficient duct depiction. Conclusions: Non-MRCP T2-weighted MRI sequences offer high performance for diagnosis of PD and are noninferior to 3D-MRCP alone. Trial registration Not applicable

    Integration of CT urography improves diagnostic confidence of 68Ga-PSMA-11 PET/CT in prostate cancer patients

    Get PDF
    Background: To prove the feasibility of integrating CT urography (CTU) into 68Ga-PSMA-11 PET/CT and to analyze the impact of CTU on assigning focal tracer accumulation in the ureteric space to either ureteric excretion or metastatic disease concerning topographic attribution and diagnostic confidence. Methods: Ten prostate cancer patients who underwent 68Ga-PSMA-11 PET/CT including CTU because of biochemical relapse or known metastatic disease were retrospectively analyzed. CTU consisted of an excretory phase 10 min after injection of 80 mL iodinated contrast material. Ureter opacification at CTU was evaluated using the following score: 0, 0% opacification; 1, < 50%; 2, 50–99%; 3, 100%. Topographic attribution and confidence of topographic attribution of focal tracer accumulation in the ureteric space were separately assessed for 68Ga-PSMA-11 PET/CT without and with CTU. Diagnostic confidence was evaluated using the following score: 0, < 25% confidence; 1, 26–50%; 2, 51–75%; 3, 76–100%. Results: At CTU, mean ureter opacification score was 2.6 ± 0.7. At 68Ga-PSMA-11 PET/CT without CTU, mean confidence of topographic attribution of focal tracer accumulation was 2.5 ± 0.7 in total and 2.6 ± 0.7 for metastatic disease. At 68Ga-PSMA-11 PET/CT with CTU, mean confidence of topographic attribution of focal areas of tracer accumulation was significantly higher with 2.9 ± 0.2 in total and 2.7 ± 0.9 for metastatic disease (p < 0.001). In 4 of 34 findings (12%) attribution to either ureteric excretion or metastatic disease was discrepant between 68Ga-PSMA-11 PET/CT without and with CTU (n.s). Conclusions: Integration of CTU into 68Ga-PSMA-11 PET/CT is feasible and increases diagnostic confidence of assigning focal areas of tracer accumulation in the ureteric space to either metastatic disease or ureteric excretion

    A search for resonances decaying into a Higgs boson and a new particle X in the XH→qqbb final state with the ATLAS detector

    Get PDF
    A search for heavy resonances decaying into a Higgs boson (HH) and a new particle (XX) is reported, utilizing 36.1 fb−1^{-1} of proton-proton collision data at s=\sqrt{s} = 13 TeV collected during 2015 and 2016 with the ATLAS detector at the CERN Large Hadron Collider. The particle XX is assumed to decay to a pair of light quarks, and the fully hadronic final state XH→qqˉâ€ČbbˉXH \rightarrow q\bar q'b\bar b is analysed. The search considers the regime of high XHXH resonance masses, where the XX and HH bosons are both highly Lorentz-boosted and are each reconstructed using a single jet with large radius parameter. A two-dimensional phase space of XHXH mass versus XX mass is scanned for evidence of a signal, over a range of XHXH resonance mass values between 1 TeV and 4 TeV, and for XX particles with masses from 50 GeV to 1000 GeV. All search results are consistent with the expectations for the background due to Standard Model processes, and 95% CL upper limits are set, as a function of XHXH and XX masses, on the production cross-section of the XH→qqˉâ€ČbbˉXH\rightarrow q\bar q'b\bar b resonance

    ECMO for COVID-19 patients in Europe and Israel

    Get PDF
    Since March 15th, 2020, 177 centres from Europe and Israel have joined the study, routinely reporting on the ECMO support they provide to COVID-19 patients. The mean annual number of cases treated with ECMO in the participating centres before the pandemic (2019) was 55. The number of COVID-19 patients has increased rapidly each week reaching 1531 treated patients as of September 14th. The greatest number of cases has been reported from France (n = 385), UK (n = 193), Germany (n = 176), Spain (n = 166), and Italy (n = 136) .The mean age of treated patients was 52.6 years (range 16–80), 79% were male. The ECMO configuration used was VV in 91% of cases, VA in 5% and other in 4%. The mean PaO2 before ECMO implantation was 65 mmHg. The mean duration of ECMO support thus far has been 18 days and the mean ICU length of stay of these patients was 33 days. As of the 14th September, overall 841 patients have been weaned from ECMO support, 601 died during ECMO support, 71 died after withdrawal of ECMO, 79 are still receiving ECMO support and for 10 patients status n.a. . Our preliminary data suggest that patients placed on ECMO with severe refractory respiratory or cardiac failure secondary to COVID-19 have a reasonable (55%) chance of survival. Further extensive data analysis is expected to provide invaluable information on the demographics, severity of illness, indications and different ECMO management strategies in these patients

    Search for dark matter produced in association with bottom or top quarks in √s = 13 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for weakly interacting massive particle dark matter produced in association with bottom or top quarks is presented. Final states containing third-generation quarks and miss- ing transverse momentum are considered. The analysis uses 36.1 fb−1 of proton–proton collision data recorded by the ATLAS experiment at √s = 13 TeV in 2015 and 2016. No significant excess of events above the estimated backgrounds is observed. The results are in- terpreted in the framework of simplified models of spin-0 dark-matter mediators. For colour- neutral spin-0 mediators produced in association with top quarks and decaying into a pair of dark-matter particles, mediator masses below 50 GeV are excluded assuming a dark-matter candidate mass of 1 GeV and unitary couplings. For scalar and pseudoscalar mediators produced in association with bottom quarks, the search sets limits on the production cross- section of 300 times the predicted rate for mediators with masses between 10 and 50 GeV and assuming a dark-matter mass of 1 GeV and unitary coupling. Constraints on colour- charged scalar simplified models are also presented. Assuming a dark-matter particle mass of 35 GeV, mediator particles with mass below 1.1 TeV are excluded for couplings yielding a dark-matter relic density consistent with measurements

    MUSiC : a model-unspecific search for new physics in proton-proton collisions at root s=13TeV

    Get PDF
    Results of the Model Unspecific Search in CMS (MUSiC), using proton-proton collision data recorded at the LHC at a centre-of-mass energy of 13 TeV, corresponding to an integrated luminosity of 35.9 fb(-1), are presented. The MUSiC analysis searches for anomalies that could be signatures of physics beyond the standard model. The analysis is based on the comparison of observed data with the standard model prediction, as determined from simulation, in several hundred final states and multiple kinematic distributions. Events containing at least one electron or muon are classified based on their final state topology, and an automated search algorithm surveys the observed data for deviations from the prediction. The sensitivity of the search is validated using multiple methods. No significant deviations from the predictions have been observed. For a wide range of final state topologies, agreement is found between the data and the standard model simulation. This analysis complements dedicated search analyses by significantly expanding the range of final states covered using a model independent approach with the largest data set to date to probe phase space regions beyond the reach of previous general searches.Peer reviewe

    Search for new particles in events with energetic jets and large missing transverse momentum in proton-proton collisions at root s=13 TeV

    Get PDF
    A search is presented for new particles produced at the LHC in proton-proton collisions at root s = 13 TeV, using events with energetic jets and large missing transverse momentum. The analysis is based on a data sample corresponding to an integrated luminosity of 101 fb(-1), collected in 2017-2018 with the CMS detector. Machine learning techniques are used to define separate categories for events with narrow jets from initial-state radiation and events with large-radius jets consistent with a hadronic decay of a W or Z boson. A statistical combination is made with an earlier search based on a data sample of 36 fb(-1), collected in 2016. No significant excess of events is observed with respect to the standard model background expectation determined from control samples in data. The results are interpreted in terms of limits on the branching fraction of an invisible decay of the Higgs boson, as well as constraints on simplified models of dark matter, on first-generation scalar leptoquarks decaying to quarks and neutrinos, and on models with large extra dimensions. Several of the new limits, specifically for spin-1 dark matter mediators, pseudoscalar mediators, colored mediators, and leptoquarks, are the most restrictive to date.Peer reviewe
    • 

    corecore