16 research outputs found

    Workshop on Regulatory Preparedness for Innovation in Nanotechnology

    Get PDF
    This report summarises the presentations and discussions at the first NanoReg2 Workshop on Regulatory Preparedness for Innovation in Nanotechnology held in Ispra, Italy 5 to 6 October 2017 and attended by approximately 60 regulators, industry representatives and other stakeholders. NanoReg2 is a European Union (EU) Horizon 2020 project. At the workshop, Regulatory Preparedness was defined as the regulators' timely awareness of innovations and the regulator's actions to check whether present legislation covers all safety aspects of each innovation, including initiating revision of the legislation as appropriate. Regulatory Preparedness, and Safe-by-Design (SbD) jointly constitute the NanoReg2 Safe Innovation Approach (SIA) for developing innovative products based on nanotechnology. The workshop aimed to gather views and identify current practices in regulatory work on safety of innovative products, tools already in use or needed, and potential difficulties in implementing Regulatory Preparedness in the EU. Presentations addressed the current state of the safety of nanotechnology innovation. The viewpoints included the regulatory framework, the principles behind it and the agencies and authorities enforcing it; nanosafety research projects and their support system (e.g. the current EU Horizon 2020 Framework Programme); national nanosafety initiatives; and the development of tools, such as foresight tools and harmonised test guidelines by the OECD for data generation. The workshop served to generate ideas for achieving Regulatory Preparedness. The participants recognised that while regulators deal with the safety of innovations, only few systematic approaches to this work exist. Some innovative products may reach the market before their safety has been appropriately assessed, as illustrated by RAPEX, the Rapid Exchange of Information System. A continuous and proactive combination of interconnected activities was considered to be required for ensuring Regulatory Preparedness. Thus, anticipation, e.g. horizon scanning, was seen as important, as was communication between regulators, innovators (industry) and other stakeholders. Regulators need to become aware of innovative products under development to ensure that the legislation and methods for safety assessment are available and adequate. Innovators must be aware of regulatory requirements and their likely development. This mutual awareness helps to develop safe products and to avoid delays or other problems in obtaining market approval. Awareness can be achieved through communication, which requires trust, e.g. promoted via "trusted environments" for confidential inquiries and information sharing. Furthermore, regulators need early access to the existing information and data relevant to safety assessment of innovative products to provide timely guidance and advice to Industry as well as to develop strategies for dealing with uncertainty, e.g. by applying the precautionary principle. Regulatory Preparedness was discussed as part of the SIA, and a "road map" of actions was suggested and outlined. The workshop has thus contributed towards acceptance of implementing Regulatory Preparedness for innovation in nanotechnology through the participation of a variety of stakeholders. This paves the way for a better dialogue among stakeholders in a fast economic development cycle, where it is even more important to quickly identify emerging needs for new approaches to regulatory issues for innovationJRC.F.2-Consumer Products Safet

    Development and Validation of a Risk Score for Chronic Kidney Disease in HIV Infection Using Prospective Cohort Data from the D:A:D Study

    Get PDF
    Ristola M. on työryhmien DAD Study Grp ; Royal Free Hosp Clin Cohort ; INSIGHT Study Grp ; SMART Study Grp ; ESPRIT Study Grp jäsen.Background Chronic kidney disease (CKD) is a major health issue for HIV-positive individuals, associated with increased morbidity and mortality. Development and implementation of a risk score model for CKD would allow comparison of the risks and benefits of adding potentially nephrotoxic antiretrovirals to a treatment regimen and would identify those at greatest risk of CKD. The aims of this study were to develop a simple, externally validated, and widely applicable long-term risk score model for CKD in HIV-positive individuals that can guide decision making in clinical practice. Methods and Findings A total of 17,954 HIV-positive individuals from the Data Collection on Adverse Events of Anti-HIV Drugs (D:A:D) study with >= 3 estimated glomerular filtration rate (eGFR) values after 1 January 2004 were included. Baseline was defined as the first eGFR > 60 ml/min/1.73 m2 after 1 January 2004; individuals with exposure to tenofovir, atazanavir, atazanavir/ritonavir, lopinavir/ritonavir, other boosted protease inhibitors before baseline were excluded. CKD was defined as confirmed (>3 mo apart) eGFR In the D:A:D study, 641 individuals developed CKD during 103,185 person-years of follow-up (PYFU; incidence 6.2/1,000 PYFU, 95% CI 5.7-6.7; median follow-up 6.1 y, range 0.3-9.1 y). Older age, intravenous drug use, hepatitis C coinfection, lower baseline eGFR, female gender, lower CD4 count nadir, hypertension, diabetes, and cardiovascular disease (CVD) predicted CKD. The adjusted incidence rate ratios of these nine categorical variables were scaled and summed to create the risk score. The median risk score at baseline was -2 (interquartile range -4 to 2). There was a 1: 393 chance of developing CKD in the next 5 y in the low risk group (risk score = 5, 505 events), respectively. Number needed to harm (NNTH) at 5 y when starting unboosted atazanavir or lopinavir/ritonavir among those with a low risk score was 1,702 (95% CI 1,166-3,367); NNTH was 202 (95% CI 159-278) and 21 (95% CI 19-23), respectively, for those with a medium and high risk score. NNTH was 739 (95% CI 506-1462), 88 (95% CI 69-121), and 9 (95% CI 8-10) for those with a low, medium, and high risk score, respectively, starting tenofovir, atazanavir/ritonavir, or another boosted protease inhibitor. The Royal Free Hospital Clinic Cohort included 2,548 individuals, of whom 94 individuals developed CKD (3.7%) during 18,376 PYFU (median follow-up 7.4 y, range 0.3-12.7 y). Of 2,013 individuals included from the SMART/ESPRIT control arms, 32 individuals developed CKD (1.6%) during 8,452 PYFU (median follow-up 4.1 y, range 0.6-8.1 y). External validation showed that the risk score predicted well in these cohorts. Limitations of this study included limited data on race and no information on proteinuria. Conclusions Both traditional and HIV-related risk factors were predictive of CKD. These factors were used to develop a risk score for CKD in HIV infection, externally validated, that has direct clinical relevance for patients and clinicians to weigh the benefits of certain antiretrovirals against the risk of CKD and to identify those at greatest risk of CKD.Peer reviewe

    One-year results of the INSIGHT study on endovascular treatment of abdominal aortic aneurysms

    No full text
    Objective: Endovascular repair of abdominal aortic aneurysms (AAAs) using the INCRAFT AAA stent graft system was safe and effective in regulatory approval studies. We herein report on the 1-year results of a real-world clinical study.Methods: The INSIGHT study is a multi-center, prospective, open label, post-approval study conducted to continually evaluate the safety and performance of the INCRAFT System. Between 2015 and 2016, 150 consecutive patients with AAA at 23 centers in Europe were treated with the device in routine clinical practice. The primary endpoint was freedom from major adverse events (MAEs), namely death, myocardial infarction, cerebrovascular accident, and renal failure, within 30 days of the index procedure. End point data were assessed by a core laboratory. The secondary end points included technical success at the conclusion of the procedure and clinical success.Results: All 150 patients studied (mean age, 73.6 +/- 8.0 years; 89.3% men) met the primary end point without MAEs at 30-day follow-up. Technical success was achieved in 99.3% of patients without stent fractures at 30 days. Among the 146 patients eligible for 1-year follow-up, the MAE rate was 8.2% (ie, 12 patients suffered 13 MAEs: cerebrovascular accident in 8, myocardial infarction in 1, and 4 died, resulting in a 2.7% all-cause mortality rate). There were no reports of new onset renal failure requiring dialysis. Only 2.7% of patients had type I endoleak, and no type III endoleaks were identified through 1 year. The rate of clinical success at 1 year was 91.8%.Conclusions: The 1-year results of this multicenter real-world study underscore the safety and effectiveness of endo-vascular treatment of AAA with the INCRAFT System in routine clinical practice

    SOLVATION OF IONS

    No full text
    corecore