1,958 research outputs found

    Observations on Some Pennsylvania Community Property Problems Part II

    Get PDF

    Common errors and clinical guidelines for manual muscle testing: "the arm test" and other inaccurate procedures

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The manual muscle test (MMT) has been offered as a chiropractic assessment tool that may help diagnose neuromusculoskeletal dysfunction. We contend that due to the number of manipulative practitioners using this test as part of the assessment of patients, clinical guidelines for the MMT are required to heighten the accuracy in the use of this tool.</p> <p>Objective</p> <p>To present essential operational definitions of the MMT for chiropractors and other clinicians that should improve the reliability of the MMT as a diagnostic test. Controversy about the usefulness and reliability of the MMT for chiropractic diagnosis is ongoing, and clinical guidelines about the MMT are needed to resolve confusion regarding the MMT as used in clinical practice as well as the evaluation of experimental evidence concerning its use.</p> <p>Discussion</p> <p>We expect that the resistance to accept the MMT as a reliable and valid diagnostic tool will continue within some portions of the manipulative professions if clinical guidelines for the use of MMT methods are not established and accepted. Unreliable assessments of this method of diagnosis will continue when non-standard MMT research papers are considered representative of the methods used by properly trained clinicians.</p> <p>Conclusion</p> <p>Practitioners who employ the MMT should use these clinical guidelines for improving their use of the MMT in their assessments of muscle dysfunction in patients with musculoskeletal pain.</p

    Strong "quantum" chaos in the global ballooning mode spectrum of three-dimensional plasmas

    Full text link
    The spectrum of ideal magnetohydrodynamic (MHD) pressure-driven (ballooning) modes in strongly nonaxisymmetric toroidal systems is difficult to analyze numerically owing to the singular nature of ideal MHD caused by lack of an inherent scale length. In this paper, ideal MHD is regularized by using a kk-space cutoff, making the ray tracing for the WKB ballooning formalism a chaotic Hamiltonian billiard problem. The minimum width of the toroidal Fourier spectrum needed for resolving toroidally localized ballooning modes with a global eigenvalue code is estimated from the Weyl formula. This phase-space-volume estimation method is applied to two stellarator cases.Comment: 4 pages typeset, including 2 figures. Paper accepted for publication in Phys. Rev. Letter

    Performance of Calcium Chloride- Ammonia Adsorption Refrigeration System

    Get PDF
    An experimental study on the performance of calcium chloride-ammonia adsorption system is described. A single bed water cooled condenser adsorption refrigerator prototype, which utilises calcium chloride-ammonia pair has been developed and tested in the laboratory. Experiments have been conducted for desorption temperatures of 100 °C with desorption time varying from 1 to 4 hours. An electric tape heater and a timer were used to perform the experiments. The adsorption temperature profile, adsorption rate and prototype performance have been analysed and discussed. The tested heating and desorption temperature of 100 °C and heating and desorption time of 1 to 4 hours was able to create a cooling effect of the cold chamber of the prototype of between -0.8 to 8.3 °C, which is adequate for vaccine storage requirement of 2 to 8 °C. The estimated Coefficient of Performance of the system ranges between 0.025 and 0. 076

    A Patterned Architecture of Monoaminergic Afferents in the Cerebellar Cortex: Noradrenergic and Serotonergic Fibre Distributions within Lobules and Parasagittal Zones

    Get PDF
    The geometry of the glutamatergic mossy-parallel fibre and climbing fibre inputs to cerebellar cortical Purkinje cells has powerfully influenced thinking about cerebellar functions. The compartmentation of the cerebellum into parasagittal zones, identifiable in olivo-cortico-nuclear projections, and the trajectories of the parallel fibres, transverse to these zones and following the long axes of the cortical folia, are particularly important. Two monoaminergic afferent systems, the serotonergic and noradrenergic, are major inputs to the cerebellar cortex but their architecture and relationship with the cortical geometry are poorly understood. Immunohistochemistry for the serotonin transporter (SERT) and for the noradrenaline transporter (NET) revealed strong anisotropy of these afferent fibres in the molecular layer of rat cerebellar cortex. Individual serotonergic fibres travel predominantly medial-lateral, along the long axes of the cortical folia, similar to parallel fibres and Zebrin II immunohistochemistry revealed that they can influence multiple zones. In contrast, individual noradrenergic fibres run predominantly parasagittally with rostral-caudal extents significantly longer than their medial-lateral deviations. Their local area of influence has similarities in form and size to those of identified microzones. Within the molecular layer, the orthogonal trajectories of these two afferent systems suggest different information processing. An individual serotonergic fibre must influence all zones and microzones within its medial-lateral trajectory. In contrast, noradrenergic fibres can influence smaller cortical territories, potentially as limited as a microzone. Evidence is emerging that these monoaminergic systems may not supply a global signal to all of their targets and their potential for cerebellar cortical functions is discussed
    • …
    corecore