684 research outputs found

    Vacuum phototriodes for the CMS electromagnetic calorimeter endcap

    Get PDF
    The measurement of scintillation light from the lead tungstate crystals of the Compact Muon Solenoid (CMS) electromagnetic calorimeter (ECAL) poses a substantial technical challenge, particularly in the endcap regions, where the radiation levels are highest. The photodetectors must be fast, sensitive, radiationhard, and operate with significant internal gain in a magnetic field of 4 Tesla. The measured performance characteristics of the first batches of series production vacuum phototriodes (VPT), developed to satisfy the needs of CMS, will be described

    Simulating Multi-channel Vacuum Phototriodes using COMSOL

    Get PDF
    Vacuum phototriodes have been used for a number of years in particle physics experiments. For 10 example, they were used in the OPAL experiment at LEP and are currently used in the endcap calorimeter of the CMS experiment at CERN’s Large Hadron Collider. A simulation of a CMS vacuum phototriode (RIE type FEU-188) has been implemented using the COMSOL multi-physics software environment. In addition, a new vacuum phototriode configured with a segmented anode, to provide four independent channels within the same overall device envelope, is presented. The induced signal as a function of time, and the effects of cross-talk in adjacent quadrants have been studied

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Meta-Analysis of Genome-Wide Association Studies for Abdominal Aortic Aneurysm Identifies Four New Disease-Specific Risk Loci

    Get PDF
    Rationale: Abdominal aortic aneurysm (AAA) is a complex disease with both genetic and environmental risk factors. Together, 6 previously identified risk loci only explain a small proportion of the heritability of AAA. Objective: To identify additional AAA risk loci using data from all available genome-wide association studies (GWAS). Methods and Results: Through a meta-analysis of 6 GWAS datasets and a validation study totalling 10,204 cases and 107,766 controls we identified 4 new AAA risk loci: 1q32.3 (SMYD2), 13q12.11 (LINC00540), 20q13.12 (near PCIF1/MMP9/ZNF335), and 21q22.2 (ERG). In various database searches we observed no new associations between the lead AAA SNPs and coronary artery disease, blood pressure, lipids or diabetes. Network analyses identified ERG, IL6R and LDLR as modifiers of MMP9, with a direct interaction between ERG and MMP9. Conclusions: The 4 new risk loci for AAA appear to be specific for AAA compared with other cardiovascular diseases and related traits suggesting that traditional cardiovascular risk factor management may only have limited value in preventing the progression of aneurysmal disease

    Search for new physics in the multijet and missing transverse momentum final state in proton-proton collisions at √s=8 Tev

    Get PDF
    Peer reviewe

    Measurement of Higgs boson production and properties in the WW decay channel with leptonic final states

    Get PDF
    Peer reviewe

    Dense, fast, radiation-tolerant Fluoro-Hafnate glass scintillators for electromagnetic calorimeters in high energy physics

    Get PDF
    Over 200 different compositions of heavy metal fluoride glasses have been produced and evaluated as possible candidates for the active medium in homogeneous electromagnetic calorimeters for high energy particles. Promising glasses, based on mixtures containing hafnium fluoride, have densities of 6 g/cm^3, radiation lengths of 1.6 cm, and good optical transmission from the UV to the IR. Glasses containing the Ce3+ ion are fast scintillators, with properties similar to those of pure cerium fluoride crystal. We have made glasses which have up to 14% of the light yield of CeF3, fast scintillation characterised by typical exponential decay constants of 10 ns and 25 ns, and a temperature dependence of light yield of -0.4%/C over the range -10C to 60C. We have carried out a detailed investigation of the effects of gamma irradiation (up to doses of 6kGy) on the optical transmission, and systematic studies into the role of indium and other elements on radiation tolerance and light yield. Some glasses have shown complete optical annealing of radiation-induced absorbance when exposed to UV light.PPAR

    Study of double parton scattering using W+2-jet events in proton-proton collisions at √s=7 TeV

    Get PDF
    Peer reviewe
    corecore