226 research outputs found

    Nitric oxide precursors and congenital heart surgery: A randomized controlled trial of oral citrulline

    Get PDF
    ObjectiveThe study sought to determine whether citrulline supplementation, a precursor to nitric oxide synthesis, is safe and efficacious in increasing plasma citrulline concentrations and decreasing the risk of postoperative pulmonary hypertension.Study DesignForty children, undergoing cardiopulmonary bypass and at risk for pulmonary hypertension, were randomized to receive 5 perioperative doses (1.9 g/m2 per dose) of either oral citrulline or placebo. Plasma citrulline and arginine concentrations were measured at 5 time points. Measurements of systemic blood pressure and presence of pulmonary hypertension were collected.ResultsMedian citrulline concentrations were significantly higher in the citrulline group versus the placebo group immediately postoperatively (36 μmol/L vs 26 μmol/L, P = .012) and at 12 hours postoperatively (37 μmol/L vs 20 μmol/L, P = .015). Mean plasma arginine concentrations were significantly higher in the citrulline group versus the placebo group by 12 hours postoperatively (36 μmol/L vs 23 μmol/L, P = .037). Mean systemic blood pressure did not differ between groups (P = .53). Postoperative pulmonary hypertension developed in 9 patients, 6 of 20 (30%) in the placebo group and 3 of 20 (15%) in the citrulline group (P = .451), all of whom had plasma citrulline concentrations less than age-specific norms. Postoperative pulmonary hypertension did not develop in patients who demonstrated plasma citrulline concentrations in excess of 37 μmol/L (P = .036).ConclusionsOral citrulline supplementation safely increased plasma citrulline and arginine concentrations compared with placebo after cardiopulmonary bypass. Postoperative pulmonary hypertension did not occur in children with naturally elevated citrulline levels or elevations through supplementation. Oral citrulline supplementation may be effective in reducing postoperative pulmonary hypertension

    Pharmacokinetics and safety of intravenously administered citrulline in children undergoing congenital heart surgery: Potential therapy for postoperative pulmonary hypertension

    Get PDF
    ObjectivePulmonary hypertension may complicate surgical correction of congenital heart defects, resulting in increased morbidity and mortality. We have previously shown that plasma levels of the nitric oxide precursors citrulline and arginine drop precipitously after congenital cardiac surgery and that oral citrulline supplementation may be protective against the development of pulmonary hypertension. In this study, we assessed the safety and pharmacokinetic profile of intravenous citrulline as a potential therapy for postoperative pulmonary hypertension.MethodsThe initial phase of this investigation was a dose-escalation study of intravenously administered citrulline in infants and children undergoing one of five congenital cardiac surgical procedures (phase 1). The primary safety outcome was a 20% drop in mean arterial blood pressure from the baseline pressure recorded after admission to the intensive care unit. Based on our previous work, the target circulating plasma citrulline trough was 80 to 100 μmol/L. Each patient was given two separate doses of citrulline: the first in the operating room immediately after initiation of cardiopulmonary bypass and the second 4 hours later in the pediatric intensive care unit. Stepwise dose escalations included 50 mg/kg, 100 mg/kg, and 150 mg/kg. After model-dependent pharmacokinetic analysis, we enrolled an additional 9 patients (phase 2) in an optimized dosing protocol that replaced the postoperative dose with a continuous infusion of citrulline at 9 mg/(kg·h) for 48 hours postoperatively.ResultsThe initial stepwise escalation protocol (phase 1) revealed that an intravenous citrulline dose of 150 mg/kg given after initiation of cardiopulmonary bypass yielded a trough level of in the target range of approximately 80 to 100 μmol/L 4 hours later. The postoperative dose revealed that the clearance of intravenously administered citrulline was 0.6 L/(h·kg), with a volume of distribution of 0.9 L/kg and estimated half-life of 60 minutes. Because of the short half-life, we altered the protocol to replace the postoperative dose with a continuous infusion of 9 mg/(kg·h). An additional 9 patients were studied with this continuous infusion protocol (phase 2). Mean plasma citrulline levels were maintained at approximately 125 μmol/L, with a calculated clearance of 0.52 L/(h·kg). None of the 17 patients studied had a 20% drop in mean arterial blood pressure from baseline.ConclusionsIn this first report of the use of intravenous citrulline in humans, we found citrulline to be both safe and well tolerated in infants and young children undergoing congenital cardiac surgery. Because of the rapid clearance, the optimal dosing regimen was identified as an initial bolus of 150 mg/kg given at the initiation of cardiopulmonary bypass, followed 4 hours later by a postoperative infusion of 9 mg/(kg·h) continued up to 48 hours. Using this regimen, plasma arginine, citrulline, and nitric oxide metabolite levels were well maintained. Intravenous citrulline needs to be studied further as a potential therapy for postoperative pulmonary hypertension

    Peptides as quorum sensing molecules : measurement techniques and obtained levels in vitro and in vivo

    Get PDF
    The expression of certain bacterial genes is regulated in a cell-density dependent way, a phenomenon called quorum sensing. Both Gram-negative and Gram-positive bacteria use this type of communication, though the signal molecules (auto-inducers) used by them differ between both groups: Gram-negative bacteria use predominantly N-acyl homoserine lacton (AHL) molecules (autoinducer-1, AI-1) while Gram-positive bacteria use mainly peptides (autoinducer peptides, AIP or quorum sensing peptides). These quorum sensing molecules are not only involved in the inter-microbial communication, but can also possibly cross-talk directly or indirectly with their host. This review summarizes the currently applied analytical approaches for quorum sensing identification and quantification with additionally summarizing the experimentally found in vivo concentrations of these molecules in humans

    Upper limit map of a background of gravitational waves

    Get PDF
    We searched for an anisotropic background of gravitational waves using data from the LIGO S4 science run and a method that is optimized for point sources. This is appropriate if, for example, the gravitational wave background is dominated by a small number of distinct astrophysical sources. No signal was seen. Upper limit maps were produced assuming two different power laws for the source strain power spectrum. For an f^-3 power law and using the 50 Hz to 1.8 kHz band the upper limits on the source strain power spectrum vary between 1.2e-48 Hz^-1 (100 Hz/f)^3 and 1.2e-47 Hz^-1 (100 Hz /f)^3, depending on the position in the sky. Similarly, in the case of constant strain power spectrum, the upper limits vary between 8.5e-49 Hz^-1 and 6.1e-48 Hz^-1. As a side product a limit on an isotropic background of gravitational waves was also obtained. All limits are at the 90% confidence level. Finally, as an application, we focused on the direction of Sco-X1, the closest low-mass X-ray binary. We compare the upper limit on strain amplitude obtained by this method to expectations based on the X-ray luminosity of Sco-X1.Comment: 11 pages, 9 figures, 2 table

    Upper limit map of a background of gravitational waves

    Get PDF
    We searched for an anisotropic background of gravitational waves using data from the LIGO S4 science run and a method that is optimized for point sources. This is appropriate if, for example, the gravitational wave background is dominated by a small number of distinct astrophysical sources. No signal was seen. Upper limit maps were produced assuming two different power laws for the source strain power spectrum. For an f^-3 power law and using the 50 Hz to 1.8 kHz band the upper limits on the source strain power spectrum vary between 1.2e-48 Hz^-1 (100 Hz/f)^3 and 1.2e-47 Hz^-1 (100 Hz /f)^3, depending on the position in the sky. Similarly, in the case of constant strain power spectrum, the upper limits vary between 8.5e-49 Hz^-1 and 6.1e-48 Hz^-1. As a side product a limit on an isotropic background of gravitational waves was also obtained. All limits are at the 90% confidence level. Finally, as an application, we focused on the direction of Sco-X1, the closest low-mass X-ray binary. We compare the upper limit on strain amplitude obtained by this method to expectations based on the X-ray luminosity of Sco-X1.Comment: 11 pages, 9 figures, 2 table

    Search for dark matter produced in association with bottom or top quarks in √s = 13 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for weakly interacting massive particle dark matter produced in association with bottom or top quarks is presented. Final states containing third-generation quarks and miss- ing transverse momentum are considered. The analysis uses 36.1 fb−1 of proton–proton collision data recorded by the ATLAS experiment at √s = 13 TeV in 2015 and 2016. No significant excess of events above the estimated backgrounds is observed. The results are in- terpreted in the framework of simplified models of spin-0 dark-matter mediators. For colour- neutral spin-0 mediators produced in association with top quarks and decaying into a pair of dark-matter particles, mediator masses below 50 GeV are excluded assuming a dark-matter candidate mass of 1 GeV and unitary couplings. For scalar and pseudoscalar mediators produced in association with bottom quarks, the search sets limits on the production cross- section of 300 times the predicted rate for mediators with masses between 10 and 50 GeV and assuming a dark-matter mass of 1 GeV and unitary coupling. Constraints on colour- charged scalar simplified models are also presented. Assuming a dark-matter particle mass of 35 GeV, mediator particles with mass below 1.1 TeV are excluded for couplings yielding a dark-matter relic density consistent with measurements

    Search of the Orion spur for continuous gravitational waves using a loosely coherent algorithm on data from LIGO interferometers

    Get PDF
    We report results of a wideband search for periodic gravitational waves from isolated neutron stars within the Orion spur towards both the inner and outer regions of our Galaxy. As gravitational waves interact very weakly with matter, the search is unimpeded by dust and concentrations of stars. One search disk (A) is 6.87° in diameter and centered on 20h10m54.71s+33°33′25.29′′, and the other (B) is 7.45° in diameter and centered on 8h35m20.61s-46°49′25.151′′. We explored the frequency range of 50-1500 Hz and frequency derivative from 0 to -5×10-9 Hz/s. A multistage, loosely coherent search program allowed probing more deeply than before in these two regions, while increasing coherence length with every stage. Rigorous follow-up parameters have winnowed the initial coincidence set to only 70 candidates, to be examined manually. None of those 70 candidates proved to be consistent with an isolated gravitational-wave emitter, and 95% confidence level upper limits were placed on continuous-wave strain amplitudes. Near 169 Hz we achieve our lowest 95% C.L. upper limit on the worst-case linearly polarized strain amplitude h0 of 6.3×10-25, while at the high end of our frequency range we achieve a worst-case upper limit of 3.4×10-24 for all polarizations and sky locations. © 2016 American Physical Society

    Search for continuous gravitational waves from 20 accreting millisecond x-ray pulsars in O3 LIGO data

    Get PDF
    corecore