3,129 research outputs found

    Search for the standard model Higgs boson in the H to ZZ to 2l 2nu channel in pp collisions at sqrt(s) = 7 TeV

    Get PDF
    A search for the standard model Higgs boson in the H to ZZ to 2l 2nu decay channel, where l = e or mu, in pp collisions at a center-of-mass energy of 7 TeV is presented. The data were collected at the LHC, with the CMS detector, and correspond to an integrated luminosity of 4.6 inverse femtobarns. No significant excess is observed above the background expectation, and upper limits are set on the Higgs boson production cross section. The presence of the standard model Higgs boson with a mass in the 270-440 GeV range is excluded at 95% confidence level.Comment: Submitted to JHE

    Combined search for the quarks of a sequential fourth generation

    Get PDF
    Results are presented from a search for a fourth generation of quarks produced singly or in pairs in a data set corresponding to an integrated luminosity of 5 inverse femtobarns recorded by the CMS experiment at the LHC in 2011. A novel strategy has been developed for a combined search for quarks of the up and down type in decay channels with at least one isolated muon or electron. Limits on the mass of the fourth-generation quarks and the relevant Cabibbo-Kobayashi-Maskawa matrix elements are derived in the context of a simple extension of the standard model with a sequential fourth generation of fermions. The existence of mass-degenerate fourth-generation quarks with masses below 685 GeV is excluded at 95% confidence level for minimal off-diagonal mixing between the third- and the fourth-generation quarks. With a mass difference of 25 GeV between the quark masses, the obtained limit on the masses of the fourth-generation quarks shifts by about +/- 20 GeV. These results significantly reduce the allowed parameter space for a fourth generation of fermions.Comment: Replaced with published version. Added journal reference and DO

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Morphology of the toe flexor muscles in older people with toe deformities

    Get PDF
    Objective: Despite suggestions that atrophied, or weak toe flexor muscles are associated with the formation of toe deformities, there has been little evidence to support this theory. This study aimed to determine whether the size of the toe flexor muscles differed in older people with and without toe deformities. Methods: Forty-four older adults (>60 years) were recruited for the study. Each participant had their feet assessed for the presence of hallux valgus or lesser toe deformities. Intrinsic and extrinsic toe flexor muscles were imaged with an ultrasound system using a standardised protocol. Assessor blinded muscle thickness and cross-sectional area was measured using Image J software. Results: Participants with lesser toe deformities (n=20) were found to have significantly smaller quadratus plantae (p=0.003), flexor digitorum brevis (p=0.013), abductor halluces (p=0.004) and flexor halluces brevis (p=0.005) muscles than the participants without any toe deformities (n=19). Female participants with hallux valgus (n=10) were found to have significantly smaller abductor hallucis (p=0.048) and flexor halluces brevis (p=0.013) muscles than the female participants without any toe deformities (n=10; p<0.05). Conclusion: This is the first study to use ultrasound to investigate the size of the toe flexor muscles in older people with hallux valgus and lesser toe deformities compared to otherwise healthy older adults. The size of the abductor hallucis and flexor hallucis brevis muscles were decreased in participants with hallux valgus whereas the quadratus plantae, flexor digitorum brevis, abductor hallucis and flexor halluces brevis muscles were smaller in those participants with lesser toe deformities

    Performance and Operation of the CMS Electromagnetic Calorimeter

    Get PDF
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    2015 recommendations for the management of polymyalgia rheumatica: a European League Against Rheumatism/American College of Rheumatology collaborative initiative

    Get PDF
    Therapy for polymyalgia rheumatica (PMR) varies widely in clinical practice as international recommendations for PMR treatment are not currently available. In this paper, we report the 2015 European League Against Rheumatism (EULAR)/American College of Rheumatology (ACR) recommendations for the management of PMR. We used the Grading of Recommendations, Assessment, Development and Evaluation (GRADE) methodology as a framework for the project. Accordingly, the direction and strength of the recommendations are based on the quality of evidence, the balance between desirable and undesirable effects, patients'and clinicians'values and preferences, and resource use. Eight overarching principles and nine specific recommendations were developed covering several aspects of PMR, including basic and follow-up investigations of patients under treatment, risk factor assessment, medical access for patients and specialist referral, treatment strategies such as initial glucocorticoid (GC) doses and subsequent tapering regimens, use of intramuscular GCs and disease modifying anti-rheumatic drugs (DMARDs), as well as the roles of non-steroidal anti-rheumatic drugs and non-pharmacological interventions. These recommendations will inform primary, secondary and tertiary care physicians about an international consensus on the management of PMR. These recommendations should serve to inform clinicians about best practices in the care of patients with PMR

    Search for light bosons in decays of the 125 GeV Higgs boson in proton-proton collisions at root s=8 TeV

    Get PDF
    Peer reviewe
    corecore