185 research outputs found

    Caracterização genética do gene da hemaglutinina em vírus da cinomose canina de cães naturalmente infectados no Brasil

    Get PDF
    Canine distemper is one of the major infectious diseases in dogs and wild animals, resulting in high morbidity and mortality. The H gene has the greatest genetic variability among the genes encoded by the canine distemper virus (CDV) genome, and it has been used to characterise field samples, allowing the identification of specific lineages. Variation in the H gene can allow the virus to evade recognition by vaccine-induced antibodies, resulting in vaccine failure. The purpose of this study was to characterise H gene in CDV strains from naturally infected dogs in the state of São Paulo. The phylogenetic analysis revealed that Brazilian CDV strains were genetically related to the circulating CDV strains in Uruguay, Argentina, and Europe. We found no evidence of South America 2 and 3 CDV lineages circulating in Brazilian dogs. The degree of genetic divergence between wild Brazilian CDV strains and vaccine strains may suggest the possibility of vaccine failures and consequently the occurrence of canine distemper outbreaks.A cinomose canina é uma das principais doenças infecciosas em cães e animais selvagens, resultando em alta morbidade e mortalidade. O gene H tem uma das maiores variabilidades genéticas entre os genes codificados pelo vírus da cinomose canina (CDV), e tem sido utilizado para caracterizar as estirpes de CDV, permitindo a identificação de linhagens específicas. A variação no gene H pode permitir que o vírus evite o reconhecimento por anticorpos induzidos pela vacina, resultando em falha vacinal. O objetivo deste estudo foi caracterizar o gene H em estirpes de CDV de cães infectados naturalmente no estado de São Paulo. A análise filogenética revelou que as estirpes de CDV brasileiras estão geneticamente relacionadas as estirpes circulantes no Uruguai, na Argentina e na Europa. Não foi encontrada nenhuma evidência da circulação no estado de São Paulo das linhagens América do Sul 2 e 3. O grau de divergência genética entre linhagens selvagens de CDV brasileiras e as estirpes vacinais podem sugerir a possibilidade de falhas vacinais e consequentemente a ocorrência de surtos de cinomose canina

    Preferences for Physical Activity: a Conjoint Analysis Involving People with Chronic Knee Pain

    Get PDF
    Objective To investigate individual preferences for physical activity (PA) attributes in adults with chronic knee pain, to identify clusters of individuals with similar preferences, and to identify whether individuals in these clusters differ by their demographic and health characteristics. Design An adaptive conjoint analysis (ACA) was conducted using the Potentially All Pairwise RanKings of all possible Alternatives (PAPRIKA) method to determine preference weights representing the relative importance of six PA attributes. Cluster analysis was performed to identify clusters of participants with similar weights. Chi-square and ANOVA were used to assess differences in individual characteristics by cluster. Multinomial logistic regression was used to assess associations between individual characteristics and cluster assignment. Results The study sample included 146 participants; mean age 65, 72% female, 47% white, non-Hispanic. The six attributes (mean weights in parentheses) are: health benefit (0.26), enjoyment (0.24), convenience (0.16), financial cost (0.13), effort (0.11) and time cost (0.10). Three clusters were identified: Cluster 1 (n = 33): for whom enjoyment (0.35) is twice as important as health benefit; Cluster 2 (n = 63): for whom health benefit (0.38) is most important; and Cluster 3 (n = 50): for whom cost (0.18), effort (0.18), health benefit (0.17) and enjoyment (0.18) are equally important. Cluster 1 was healthiest, Cluster 2 most self-efficacious, and Cluster 3 was in poorest health. Conclusions Patients with chronic knee pain have preferences for PA that can be distinguished effectively using ACA methods. Adults with chronic knee pain, clustered by PA preferences, share distinguishing characteristics. Understanding preferences may help clinicians and researchers to better tailor PA interventions

    Continuous Glucose Monitors and Automated Insulin Dosing Systems in the Hospital Consensus Guideline.

    Get PDF
    This article is the work product of the Continuous Glucose Monitor and Automated Insulin Dosing Systems in the Hospital Consensus Guideline Panel, which was organized by Diabetes Technology Society and met virtually on April 23, 2020. The guideline panel consisted of 24 international experts in the use of continuous glucose monitors (CGMs) and automated insulin dosing (AID) systems representing adult endocrinology, pediatric endocrinology, obstetrics and gynecology, advanced practice nursing, diabetes care and education, clinical chemistry, bioengineering, and product liability law. The panelists reviewed the medical literature pertaining to five topics: (1) continuation of home CGMs after hospitalization, (2) initiation of CGMs in the hospital, (3) continuation of AID systems in the hospital, (4) logistics and hands-on care of hospitalized patients using CGMs and AID systems, and (5) data management of CGMs and AID systems in the hospital. The panelists then developed three types of recommendations for each topic, including clinical practice (to use the technology optimally), research (to improve the safety and effectiveness of the technology), and hospital policies (to build an environment for facilitating use of these devices) for each of the five topics. The panelists voted on 78 proposed recommendations. Based on the panel vote, 77 recommendations were classified as either strong or mild. One recommendation failed to reach consensus. Additional research is needed on CGMs and AID systems in the hospital setting regarding device accuracy, practices for deployment, data management, and achievable outcomes. This guideline is intended to support these technologies for the management of hospitalized patients with diabetes

    Next Generation Short-Term Forecasting of Wind Power – Overview of the ANEMOS Project.

    No full text
    International audienceThe aim of the European Project ANEMOS is to develop accurate and robust models that substantially outperform current state-of-the-art methods, for onshore and offshore wind power forecasting. Advanced statistical, physical and combined modelling approaches were developed for this purpose. Priority was given to methods for on-line uncertainty and prediction risk assessment. An integrated software platform, 'ANEMOS', was developed to host the various models. This system is installed by several end-users for on-line operation and evaluation at a local, regional and national scale. Finally, the project demonstrates the value of wind forecasts for the power system management and market integration of wind power. Keywords: Wind power, short-term forecasting, numerical weather predictions, on-line software, tools for wind integration

    A Glycemia Risk Index (GRI) of Hypoglycemia and Hyperglycemia for Continuous Glucose Monitoring Validated by Clinician Ratings

    Get PDF
    BackgroundA composite metric for the quality of glycemia from continuous glucose monitor (CGM) tracings could be useful for assisting with basic clinical interpretation of CGM data.MethodsWe assembled a data set of 14-day CGM tracings from 225 insulin-treated adults with diabetes. Using a balanced incomplete block design, 330 clinicians who were highly experienced with CGM analysis and interpretation ranked the CGM tracings from best to worst quality of glycemia. We used principal component analysis and multiple regressions to develop a model to predict the clinician ranking based on seven standard metrics in an Ambulatory Glucose Profile: very low-glucose and low-glucose hypoglycemia; very high-glucose and high-glucose hyperglycemia; time in range; mean glucose; and coefficient of variation.ResultsThe analysis showed that clinician rankings depend on two components, one related to hypoglycemia that gives more weight to very low-glucose than to low-glucose and the other related to hyperglycemia that likewise gives greater weight to very high-glucose than to high-glucose. These two components should be calculated and displayed separately, but they can also be combined into a single Glycemia Risk Index (GRI) that corresponds closely to the clinician rankings of the overall quality of glycemia (r = 0.95). The GRI can be displayed graphically on a GRI Grid with the hypoglycemia component on the horizontal axis and the hyperglycemia component on the vertical axis. Diagonal lines divide the graph into five zones (quintiles) corresponding to the best (0th to 20th percentile) to worst (81st to 100th percentile) overall quality of glycemia. The GRI Grid enables users to track sequential changes within an individual over time and compare groups of individuals.ConclusionThe GRI is a single-number summary of the quality of glycemia. Its hypoglycemia and hyperglycemia components provide actionable scores and a graphical display (the GRI Grid) that can be used by clinicians and researchers to determine the glycemic effects of prescribed and investigational treatments

    THE CONCISE GUIDE TO PHARMACOLOGY 2021/22: G protein-coupled receptors

    Get PDF
    The Concise Guide to PHARMACOLOGY 2021/22 is the fifth in this series of biennial publications. The Concise Guide provides concise overviews, mostly in tabular format, of the key properties of nearly 1900 human drug targets with an emphasis on selective pharmacology (where available), plus links to the open access knowledgebase source of drug targets and their ligands (www.guidetopharmacology.org), which provides more detailed views of target and ligand properties. Although the Concise Guide constitutes over 500 pages, the material presented is substantially reduced compared to information and links presented on the website. It provides a permanent, citable, point-in-time record that will survive database updates. The full contents of this section can be found at http://onlinelibrary.wiley.com/doi/bph.15538. G protein-coupled receptors are one of the six major pharmacological targets into which the Guide is divided, with the others being: ion channels, nuclear hormone receptors, catalytic receptors, enzymes and transporters. These are presented with nomenclature guidance and summary information on the best available pharmacological tools, alongside key references and suggestions for further reading. The landscape format of the Concise Guide is designed to facilitate comparison of related targets from material contemporary to mid-2021, and supersedes data presented in the 2019/20, 2017/18, 2015/16 and 2013/14 Concise Guides and previous Guides to Receptors and Channels. It is produced in close conjunction with the Nomenclature and Standards Committee of the International Union of Basic and Clinical Pharmacology (NC-IUPHAR), therefore, providing official IUPHAR classification and nomenclature for human drug targets, where appropriate

    THE CONCISE GUIDE TO PHARMACOLOGY 2019/20 : G protein- coupled receptors

    Get PDF
    The Concise Guide to PHARMACOLOGY 2019/20 is the fourth in this series of biennial publications. The Concise Guide provides concise overviews of the key properties of nearly 1800 human drug targets with an emphasis on selective pharmacology (where available), plus links to the open access knowledgebase source of drug targets and their ligands (www.guidetopharmacology.org), which provides more detailed views of target and ligand properties. Although the Concise Guide represents approximately 400 pages, the material presented is substantially reduced compared to information and links presented on the website. It provides a permanent, citable, point-in-time record that will survive database updates. The full contents of this section can be found at http://onlinelibrary.wiley.com/doi/10.1111/bph.14748. G protein-coupled receptors are one of the six major pharmacological targets into which the Guide is divided, with the others being: ion channels, nuclear hormone receptors, catalytic receptors, enzymes and transporters. These are presented with nomenclature guidance and summary information on the best available pharmacological tools, alongside key references and suggestions for further reading. The landscape format of the Concise Guide is designed to facilitate comparison of related targets from material contemporary to mid-2019, and supersedes data presented in the 2017/18, 2015/16 and 2013/14 Concise Guides and previous Guides to Receptors and Channels. It is produced in close conjunction with the International Union of Basic and Clinical Pharmacology Committee on Receptor Nomenclature and Drug Classification (NC-IUPHAR), therefore, providing official IUPHAR classification and nomenclature for human drug targets, where appropriate.Peer reviewe

    Search for dark matter produced in association with bottom or top quarks in √s = 13 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for weakly interacting massive particle dark matter produced in association with bottom or top quarks is presented. Final states containing third-generation quarks and miss- ing transverse momentum are considered. The analysis uses 36.1 fb−1 of proton–proton collision data recorded by the ATLAS experiment at √s = 13 TeV in 2015 and 2016. No significant excess of events above the estimated backgrounds is observed. The results are in- terpreted in the framework of simplified models of spin-0 dark-matter mediators. For colour- neutral spin-0 mediators produced in association with top quarks and decaying into a pair of dark-matter particles, mediator masses below 50 GeV are excluded assuming a dark-matter candidate mass of 1 GeV and unitary couplings. For scalar and pseudoscalar mediators produced in association with bottom quarks, the search sets limits on the production cross- section of 300 times the predicted rate for mediators with masses between 10 and 50 GeV and assuming a dark-matter mass of 1 GeV and unitary coupling. Constraints on colour- charged scalar simplified models are also presented. Assuming a dark-matter particle mass of 35 GeV, mediator particles with mass below 1.1 TeV are excluded for couplings yielding a dark-matter relic density consistent with measurements
    corecore