28 research outputs found

    Hemodynamic impact of isobaric levobupivacaine versus hyperbaric bupivacaine for subarachnoid anesthesia in patients aged 65 and older undergoing hip surgery

    Get PDF
    BackgroundThe altered hemodynamics, and therefore the arterial hypotension is the most prevalent adverse effect after subarachnoid anesthesia. The objective of the study was to determine the exact role of local anesthetic selection underlying spinal anesthesia-induced hypotension in the elderly patient. We conducted a descriptive, observational pilot study to assess the hemodynamic impact of subarachnoid anesthesia with isobaric levobupivacaine versus hyperbaric bupivacaine for hip fracture surgery.DescriptionHundred twenty ASA status I-IV patients aged 65 and older undergoing hip fracture surgery were enrolled. The primary objective of our study was to compare hemodynamic effects based on systolic blood pressure (SBP) and dyastolic blood pressure (DBP) values, heart rate (HR) and hemoglobin (Hb) and respiratory effects based on partial oxygen saturation (SpO2%) values. The secondary objective was to assess potential adverse events with the use of levobupivacaine versus bupivacaine. Assessments were performed preoperatively, at 30 minutes into surgery, at the end of anesthesia and at 48 hours and 6 months after surgery.Among intraoperative events, the incidence of hypotension was statistically significantly higher (p <0.05) in group BUPI (38.3%) compared to group LEVO (13.3%). There was a decrease (p <0.05) in systolic blood pressure (SBP) and diastolic blood pressure (DBP) at 30 minutes intraoperatively (19% in group BUPI versus 17% in group LEVO). SpO2% increased at 30 minutes after anesthesia onset (1% in group BUPI versus 1.5% in group LEVO). Heart rate (HR) decreased at 30 minutes after anesthesia onset (5% in group BUPI versus 9% in group L). Hemoglobin (Hb) decreased from time of operating room (OR) admission to the end of anesthesia (9.3% in group BUPI versus 12.5% in group LEVO). The incidence of red blood cell (RBC) transfusion was 13.3% in group BUPI versus 31.7% in group LEVO, this difference was statistically significant. Among postoperative events, the incidence of congestive heart failure (CHF) was significantly higher in group BUPI (8,3%). At 6 months after anesthesia, no differences were found.ConclusionsGiven the hemodynamic stability and lower incidence of intraoperative hypotension observed, levobupivacaine could be the agent of choice for subarachnoid anesthesia in elderly patients

    Documento de la Sociedad Española de Hipertensión-Liga Española para la Lucha contra la Hipertensión Arterial (SEH-LELHA) sobre las guías ACC/AHA 2017 de hipertensión arterial

    Get PDF
    The American College of Cardiology (ACC) and the American Heart Association (AHA) have recently published their guidelines for the prevention, detection, evaluation, and management of hypertension in adults. The most controversial issue is the classification threshold at 130/80 mmHg, which will allow a large number of patients to be diagnosed as hypertensive who were previously considered normotensive. Blood pressure (BP) is considered normal (<120 mmHg systolic and <80 mmHg diastolic), elevated (120-129 and <80 mmHg), stage 1 (130-139 or 80-89 mmHg), and stage 2 (≥140 or ≥90 mmHg). Out-of-office BP measurements are recommended to confirm the diagnosis of hypertension and for titration of BP-lowering medication. In management, cardiovascular risk would be determinant since those with grade 1 hypertension and an estimated 10-year risk of atherosclerotic cardiovascular disease ≥10%, and those with cardiovascular disease, chronic kidney disease and/or diabetes will require pharmacological treatment, the rest being susceptible to non-pharmacological treatment up to the 140/90 mmHg threshold. These recommendations would allow patients with level 1 hypertension and high atherosclerotic cardiovascular disease to benefit from pharmacological therapies and all patients could also benefit from improved non-pharmacological therapies. However, this approach should be cautious because inadequate BP measurement and/or lack of systematic atherosclerotic cardiovascular disease calculation could lead to overestimation in diagnosing hypertension and to overtreatment. Guidelines are recommendations, not impositions, and the management of hypertension should be individualized, based on clinical decisions, preferences of the patients, and an adequate balance between benefits and risks

    Multimessenger NuEM Alerts with AMON

    Get PDF
    The Astrophysical Multimessenger Observatory Network (AMON), has developed a real-time multi-messenger alert system. The system performs coincidence analyses of datasets from gamma-ray and neutrino detectors, making the Neutrino-Electromagnetic (NuEM) alert channel. For these analyses, AMON takes advantage of sub-threshold events, i.e., events that by themselves are not significant in the individual detectors. The main purpose of this channel is to search for gamma-ray counterparts of neutrino events. We will describe the different analyses that make-up this channel and present a selection of recent results

    Multi-messenger observations of a binary neutron star merger

    Get PDF
    On 2017 August 17 a binary neutron star coalescence candidate (later designated GW170817) with merger time 12:41:04 UTC was observed through gravitational waves by the Advanced LIGO and Advanced Virgo detectors. The Fermi Gamma-ray Burst Monitor independently detected a gamma-ray burst (GRB 170817A) with a time delay of ~1.7 s with respect to the merger time. From the gravitational-wave signal, the source was initially localized to a sky region of 31 deg2 at a luminosity distance of 40+8-8 Mpc and with component masses consistent with neutron stars. The component masses were later measured to be in the range 0.86 to 2.26 Mo. An extensive observing campaign was launched across the electromagnetic spectrum leading to the discovery of a bright optical transient (SSS17a, now with the IAU identification of AT 2017gfo) in NGC 4993 (at ~40 Mpc) less than 11 hours after the merger by the One- Meter, Two Hemisphere (1M2H) team using the 1 m Swope Telescope. The optical transient was independently detected by multiple teams within an hour. Subsequent observations targeted the object and its environment. Early ultraviolet observations revealed a blue transient that faded within 48 hours. Optical and infrared observations showed a redward evolution over ~10 days. Following early non-detections, X-ray and radio emission were discovered at the transient’s position ~9 and ~16 days, respectively, after the merger. Both the X-ray and radio emission likely arise from a physical process that is distinct from the one that generates the UV/optical/near-infrared emission. No ultra-high-energy gamma-rays and no neutrino candidates consistent with the source were found in follow-up searches. These observations support the hypothesis that GW170817 was produced by the merger of two neutron stars in NGC4993 followed by a short gamma-ray burst (GRB 170817A) and a kilonova/macronova powered by the radioactive decay of r-process nuclei synthesized in the ejecta

    International nosocomial infection control consortium (INICC) report, data summary of 36 countries, for 2004-2009

    Get PDF
    The results of a surveillance study conducted by the International Nosocomial Infection Control Consortium (INICC) from January 2004 through December 2009 in 422 intensive care units (ICUs) of 36 countries in Latin America, Asia, Africa, and Europe are reported. During the 6-year study period, using Centers for Disease Control and Prevention (CDC) National Healthcare Safety Network (NHSN; formerly the National Nosocomial Infection Surveillance system [NNIS]) definitions for device-associated health care-associated infections, we gathered prospective data from 313,008 patients hospitalized in the consortium's ICUs for an aggregate of 2,194,897 ICU bed-days. Despite the fact that the use of devices in the developing countries' ICUs was remarkably similar to that reported in US ICUs in the CDC's NHSN, rates of device-associated nosocomial infection were significantly higher in the ICUs of the INICC hospitals; the pooled rate of central line-associated bloodstream infection in the INICC ICUs of 6.8 per 1,000 central line-days was more than 3-fold higher than the 2.0 per 1,000 central line-days reported in comparable US ICUs. The overall rate of ventilator-associated pneumonia also was far higher (15.8 vs 3.3 per 1,000 ventilator-days), as was the rate of catheter-associated urinary tract infection (6.3 vs. 3.3 per 1,000 catheter-days). Notably, the frequencies of resistance of Pseudomonas aeruginosa isolates to imipenem (47.2% vs 23.0%), Klebsiella pneumoniae isolates to ceftazidime (76.3% vs 27.1%), Escherichia coli isolates to ceftazidime (66.7% vs 8.1%), Staphylococcus aureus isolates to methicillin (84.4% vs 56.8%), were also higher in the consortium's ICUs, and the crude unadjusted excess mortalities of device-related infections ranged from 7.3% (for catheter-associated urinary tract infection) to 15.2% (for ventilator-associated pneumonia). Copyright © 2012 by the Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved

    A prospective study of adverse drug reactions as a cause of admission to a paediatric hospital

    No full text
    1A total of 512 consecutive paediatric hospital admissions of children 2 years old or less were evaluated to assess the extent and pattern of admission caused by suspected adverse drug reactions (ADRs). The proportion of suspected ADRs related to hospital admissions was 4.3%
    corecore