88 research outputs found

    System size dependence of strange particle yields and spectra at sqrt(s)=17.3 GeV

    Get PDF
    Yields and spectra of strange hadrons (K+, K-, phi, Lambda and Antilambda) as well as of charged pions were measured in near central C+C and Si+Si collisions at 158 AGeV beam energy with the NA49 detector. Together with earlier data for p+p, S+S and Pb+Pb reactions the system size dependence can be studied. Relative strangeness production rises fast and saturates at about 60 participating nucleons; the net hyperon spectra show an increasing shift towards midrapidity for larger colliding nuclei. An interpretation based on the formation of coherent systems of increasing volume is proposed. The transverse mass spectra can be described by a blast wave ansatz. Increasing flow velocity is accompanied by decreasing temperatures for both kinetic and chemical freeze out. The increasing gap between inelastic and elastic decoupling leaves space for rescattering.Comment: 8 pages, 6 figures, Proceedings of the Hot Quarks 2004 worksho

    Precise determination of the mass of the Higgs boson and tests of compatibility of its couplings with the standard model predictions using proton collisions at 7 and 8 TeV

    Get PDF
    Peer reviewe

    Measurement of the Zγ production cross section in pp collisions at 8 TeV and search for anomalous triple gauge boson couplings

    Get PDF
    Open Access, Copyright CERN, for the benefit of the CMS Collaboration. Article funded by SCOAP3.Abstract: The cross section for the production of Zγ in proton-proton collisions at 8 TeV is measured based on data collected by the CMS experiment at the LHC corresponding to an integrated luminosity of 19.5 fb−1. Events with an oppositely-charged pair of muons or electrons together with an isolated photon are selected. The differential cross section as a function of the photon transverse momentum is measured inclusively and exclusively, where the exclusive selection applies a veto on central jets. The observed cross sections are compatible with the expectations of next-to-next-to-leading-order quantum chromodynamics. Limits on anomalous triple gauge couplings of ZZγ and Zγγ are set that improve on previous experimental results obtained with the charged lepton decay modes of the Z boson

    Intraperitoneal drain placement and outcomes after elective colorectal surgery: international matched, prospective, cohort study

    Get PDF
    Despite current guidelines, intraperitoneal drain placement after elective colorectal surgery remains widespread. Drains were not associated with earlier detection of intraperitoneal collections, but were associated with prolonged hospital stay and increased risk of surgical-site infections.Background Many surgeons routinely place intraperitoneal drains after elective colorectal surgery. However, enhanced recovery after surgery guidelines recommend against their routine use owing to a lack of clear clinical benefit. This study aimed to describe international variation in intraperitoneal drain placement and the safety of this practice. Methods COMPASS (COMPlicAted intra-abdominal collectionS after colorectal Surgery) was a prospective, international, cohort study which enrolled consecutive adults undergoing elective colorectal surgery (February to March 2020). The primary outcome was the rate of intraperitoneal drain placement. Secondary outcomes included: rate and time to diagnosis of postoperative intraperitoneal collections; rate of surgical site infections (SSIs); time to discharge; and 30-day major postoperative complications (Clavien-Dindo grade at least III). After propensity score matching, multivariable logistic regression and Cox proportional hazards regression were used to estimate the independent association of the secondary outcomes with drain placement. Results Overall, 1805 patients from 22 countries were included (798 women, 44.2 per cent; median age 67.0 years). The drain insertion rate was 51.9 per cent (937 patients). After matching, drains were not associated with reduced rates (odds ratio (OR) 1.33, 95 per cent c.i. 0.79 to 2.23; P = 0.287) or earlier detection (hazard ratio (HR) 0.87, 0.33 to 2.31; P = 0.780) of collections. Although not associated with worse major postoperative complications (OR 1.09, 0.68 to 1.75; P = 0.709), drains were associated with delayed hospital discharge (HR 0.58, 0.52 to 0.66; P < 0.001) and an increased risk of SSIs (OR 2.47, 1.50 to 4.05; P < 0.001). Conclusion Intraperitoneal drain placement after elective colorectal surgery is not associated with earlier detection of postoperative collections, but prolongs hospital stay and increases SSI risk

    Measurement of the production cross section ratio σ(χb2(1P))/σ(χb1(1P))in pp collisions at √s=8TeV

    Get PDF
    A measurement of the production cross section ratio σ(χb2(1P))/σ(χb1(1P))σ(χb2(1P))/σ(χb1(1P)) is presented. The χb1(1P)χb1(1P) and χb2(1P)χb2(1P) bottomonium states, promptly produced in pp collisions at View the MathML sources=8 TeV, are detected by the CMS experiment at the CERN LHC through their radiative decays χb1,2(1P)→ϒ(1S)+γχb1,2(1P)→ϒ(1S)+γ. The emitted photons are measured through their conversion to e+e−e+e− pairs, whose reconstruction allows the two states to be resolved. The ϒ(1S)ϒ(1S) is measured through its decay to two muons. An event sample corresponding to an integrated luminosity of 20.7 fb−120.7 fb−1 is used to measure the cross section ratio in a phase-space region defined by the photon pseudorapidity, |ηγ|<1.0|ηγ|<1.0; the ϒ(1S)ϒ(1S) rapidity, |yϒ|<1.5|yϒ|<1.5; and the ϒ(1S)ϒ(1S) transverse momentum, View the MathML source7<pTϒ<40 GeV. The cross section ratio shows no significant dependence on the ϒ(1S)ϒ(1S) transverse momentum, with a measured average value of View the MathML source0.85±0.07(stat+syst)±0.08(BF), where the first uncertainty is the combination of the experimental statistical and systematic uncertainties and the second is from the uncertainty in the ratio of the χbχb branching fractions

    Measurement of the top-quark mass in tt¯ events with dilepton final states in pp collisions at √s = 7 TeV

    Get PDF
    Open Access: This article is distributed under the terms of the Creative Commons Attribution License.-- Chatrchyan, S. et al.The top-quark mass is measured in proton-proton collisions at s√=7 TeV using a data sample corresponding to an integrated luminosity of 5.0 fb−1 collected by the CMS experiment at the LHC. The measurement is performed in the dilepton decay channel tt¯→(ℓ+νℓb)(ℓ−ν¯¯ℓb¯), where ℓ=e,μ. Candidate top-quark decays are selected by requiring two leptons, at least two jets, and imbalance in transverse momentum. The mass is reconstructed with an analytical matrix weighting technique using distributions derived from simulated samples. Using a maximum-likelihood fit, the top-quark mass is determined to be 172.5±0.4 (stat.)±1.5 (syst.) GeV.Acknowledge support from BMWF and FWF (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); MoER, SF0690030s09 and ERDF (Estonia); Academy of Finland, MEC, and HIP (Finland); CEA and CNRS/IN2P3 (France);BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF and WCU (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); MSI (New Zealand); PAEC (Pakistan); MSHE and NSC (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MON, RosAtom, RAS and RFBR (Russia); MSTD (Serbia); SEIDI and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); ThEP, IPST and NECTEC (Thailand); TUBITAK and TAEK (Turkey); NASU (Ukraine); STFC (United Kingdom); DOE and NSF (USA). Individuals have received support from the Marie-Curie program and the European Research Council (European Union); the Leventis Foundation; the A. P. Sloan Foundation; the Alexander von Humboldt Foundation; the Austrian Science Fund (FWF); the Belgian Federal Science Policy Office; the Fonds pour la Formation à la Recherche dans l’Industrie et dans l’Agriculture (FRIA-Belgium); the Agentschap voor Innovatie door Wetenschap en Technologie (IWTBelgium); the Ministry of Education, Youth and Sports (MEYS) of Czech Republic; the Council of Science and Industrial Research, India; the Compagnia di San Paolo (Torino); and the HOMING PLUS program of Foundation for Polish Science, cofinanced from European Union, Regional Development Fund.Peer Reviewe

    Searches for new physics using the t(t)over-bar invariant mass distribution in pp collisions at √s=8 TeV

    Get PDF
    This is the pre-print version of the final published paper that is available from the link belowSearches for anomalous top quark-antiquark production are presented, based on pp collisions at √s=8  TeV . The data, corresponding to an integrated luminosity of 19:7 fb^-1, were collected with the CMS detector at the LHC. The observed tt invariant mass spectrum is found to be compatible with the standard model prediction. Limits on the production cross section times branching fraction probe, for the first time, a region of parameter space for certain models of new physics not yet constrained by precision measurements

    Measurements of b-jet nuclear modification factors in pPb and PbPb collisions with CMS

    Get PDF

    Measurements of the t(t)over-bar production cross section in lepton plus jets final states in pp collisions at 8 and ratio of 8 to 7 TeV cross sections

    Get PDF
    Peer reviewe

    Measurements of the Upsilon(1S), Upsilon(2S), and Upsilon(3S) differential cross sections in pp collisions at root s=7 TeV

    Get PDF
    Peer reviewe
    corecore