136 research outputs found

    Reduced Atrial Tachyarrhythmia Susceptibility After Upgrade of Conventional Implanted Pulse Generator to Cardiac Resynchronization Therapy in Patients with Heart Failure

    Get PDF
    OBJECTIVES: We sought to identify the impact of cardiac resynchronization therapy (CRT) on atrial tachyarrhythmia (AT) susceptibility in patients with left ventricular (LV) systolic dysfunction in whom worsening heart failure (HF) resulted in upgrade from conventional dual-chamber pulse generator to cardiac resynchronization therapy-defibrillator (CRT-D). BACKGROUND: Cardiac resynchronization therapy with a defibrillator improves survival rates and symptoms in patients with LV systolic dysfunction but little is known about its effects on AT incidence in the same patient population. METHODS: Twenty-eight consecutive HF patients who underwent device upgrade to CRT-D were included. Patients had \u3e or =2 device interrogations in the 1 year before upgrade and \u3e or =3 interrogations in the 18- to 24-month follow-up after upgrade. Echocardiographic parameters were assessed before and at 3 to 6 months after CRT-D. Additional observations included number of hospital stays, HF clinical status, and concomitant pharmacological therapy. By virtue of this study design, each patient served as his/her own control. Statistical analysis was performed by 2-tailed paired t test and with nonparametric tests where appropriate. RESULTS: Within 3 months after CRT, the number of HF patients with documented AT decreased significantly from the immediate pre-CRT value and tended to decline with time. At 1-year follow-up, 90% of patients were AT-free compared with 14% of patients 3 months before CRT (p \u3c 0.001). Furthermore, the number of AT episodes/year and their maximum duration decreased after CRT (mean +/- SD; 181 +/- 50 vs. 50 +/- 20.2, p \u3c 0.05, and 220.8 +/- 87 s vs. 28 +/- 21 s, p \u3c 0.05, respectively). Finally, CRT was associated with improved LV ejection fraction (mean +/- SD; from 26 +/- 5.3% to 31 +/- 7%, p \u3c 0.001) and reduced number of HF or arrhythmia hospital stays (p \u3c 0.05). CONCLUSIONS: Our findings support the view that CRT might decrease AT susceptibility in HF patients with LV systolic dysfunctio

    Relationship of Paroxysmal Atrial Tachyarrhythmias to Volume Overload

    Get PDF
    BACKGROUND: Clinical experience suggests that atrial tachyarrhythmias (ATs) are a frequent comorbidity in heart failure patients with left ventricular systolic dysfunction and that volume overload may increase AT susceptibility. However, substantiating this apparent relationship in free-living patients is difficult. Recently, certain implantable cardioverter-defibrillators provide, by measuring transpulmonary electric bioimpedance, an index of intrathoracic fluid status (OptiVol index [OI]). The goal of this study was to determine whether periods of greater intrathoracic fluid congestion (as detected by OI) correspond with increased AT event frequency. METHODS AND RESULTS: This analysis retrospectively assessed the relation between AT events and OI estimate of volume overload in patients with left ventricular systolic dysfunction and OI-capable implantable cardioverter-defibrillators. OI values were stratified into 3 levels: group 1, \u3c40; group 2, 40 to 60; and group 3, \u3e60. An OI threshold-crossing event was defined as OI \u3e or = 60, a value previously associated with clinically significant volume overload. Findings in 59 patients (mean left ventricular ejection fraction, 24%) with 225 follow-up visits (mean, 3.8 visits per patient) were evaluated. AT prevalence was 73%. AT frequency (percent of patients visits with at least 1 episode of AT since previous device interrogation) was greater in group 3 versus group 1 (P=0.0342). Finally, in terms of temporal sequence, AT episodes preceded OI threshold-crossing event in 43% of incidences, followed threshold-crossing event in 29%, and was simultaneous or indeterminate in the remainder. CONCLUSIONS: These findings not only support the view that worsening pulmonary congestion is associated with increased AT frequency in patients with left ventricular dysfunction but also suggest that AT events may be responsible for triggering episodic pulmonary congestion more often than previously suspected

    Nuclear structure corrections in the energy spectra of electronic and muonic deuterium

    Get PDF
    The one-loop nuclear structure corrections of order (Z alpha)^5 to the Lamb shift and hyperfine splitting of the deuterium are calculated. The contribution of the deuteron structure effects to the isotope shift (ep)-(ed), (mu p)-(mu d) in the interval (1S - 2S) is obtained on the basis of modern experimental data on the deuteron electromagnetic form factors. The comparison with the similar contributions to the Lamb shift for electronic and muonic hydrogen shows, that the relative contribution due to the nucleus structure increases when passing from the hydrogen to the deuterium.Comment: Talk presented at the Conference "Physics of Fundamental Interactions" of the Nuclear Physics Section of the Physics Department of RAS, ITEP, Moscow, 2-6 December, 2002; 8 pages, REVTE

    Chlorpromazine versus placebo for schizophrenia

    Get PDF

    Image perception and interpretation of abnormalities; can we believe our eyes? Can we do something about it?

    Get PDF
    The radiologist’s visual impression of images is transmitted, via non-visual means (the report), to the clinician. There are several complex steps from the perception of the images by the radiologist to the understanding of the impression by the clinician. With a process as complex as this, it is no wonder that errors in perception, cognition, interpretation, transmission and understanding are very common. This paper reviews the processes of perception and error generation and possible strategies for minimising them

    Brownian motors: noisy transport far from equilibrium

    Full text link
    Transport phenomena in spatially periodic systems far from thermal equilibrium are considered. The main emphasize is put on directed transport in so-called Brownian motors (ratchets), i.e. a dissipative dynamics in the presence of thermal noise and some prototypical perturbation that drives the system out of equilibrium without introducing a priori an obvious bias into one or the other direction of motion. Symmetry conditions for the appearance (or not) of directed current, its inversion upon variation of certain parameters, and quantitative theoretical predictions for specific models are reviewed as well as a wide variety of experimental realizations and biological applications, especially the modeling of molecular motors. Extensions include quantum mechanical and collective effects, Hamiltonian ratchets, the influence of spatial disorder, and diffusive transport.Comment: Revised version (Aug. 2001), accepted for publication in Physics Report

    Epidemiology and patterns of tracheostomy practice in patients with acute respiratory distress syndrome in ICUs across 50 countries

    Get PDF
    Background: To better understand the epidemiology and patterns of tracheostomy practice for patients with acute respiratory distress syndrome (ARDS), we investigated the current usage of tracheostomy in patients with ARDS recruited into the Large Observational Study to Understand the Global Impact of Severe Acute Respiratory Failure (LUNG-SAFE) study. Methods: This is a secondary analysis of LUNG-SAFE, an international, multicenter, prospective cohort study of patients receiving invasive or noninvasive ventilation in 50 countries spanning 5 continents. The study was carried out over 4 weeks consecutively in the winter of 2014, and 459 ICUs participated. We evaluated the clinical characteristics, management and outcomes of patients that received tracheostomy, in the cohort of patients that developed ARDS on day 1-2 of acute hypoxemic respiratory failure, and in a subsequent propensity-matched cohort. Results: Of the 2377 patients with ARDS that fulfilled the inclusion criteria, 309 (13.0%) underwent tracheostomy during their ICU stay. Patients from high-income European countries (n = 198/1263) more frequently underwent tracheostomy compared to patients from non-European high-income countries (n = 63/649) or patients from middle-income countries (n = 48/465). Only 86/309 (27.8%) underwent tracheostomy on or before day 7, while the median timing of tracheostomy was 14 (Q1-Q3, 7-21) days after onset of ARDS. In the subsample matched by propensity score, ICU and hospital stay were longer in patients with tracheostomy. While patients with tracheostomy had the highest survival probability, there was no difference in 60-day or 90-day mortality in either the patient subgroup that survived for at least 5 days in ICU, or in the propensity-matched subsample. Conclusions: Most patients that receive tracheostomy do so after the first week of critical illness. Tracheostomy may prolong patient survival but does not reduce 60-day or 90-day mortality. Trial registration: ClinicalTrials.gov, NCT02010073. Registered on 12 December 2013

    Geoeconomic variations in epidemiology, ventilation management, and outcomes in invasively ventilated intensive care unit patients without acute respiratory distress syndrome: a pooled analysis of four observational studies

    Get PDF
    Background: Geoeconomic variations in epidemiology, the practice of ventilation, and outcome in invasively ventilated intensive care unit (ICU) patients without acute respiratory distress syndrome (ARDS) remain unexplored. In this analysis we aim to address these gaps using individual patient data of four large observational studies. Methods: In this pooled analysis we harmonised individual patient data from the ERICC, LUNG SAFE, PRoVENT, and PRoVENT-iMiC prospective observational studies, which were conducted from June, 2011, to December, 2018, in 534 ICUs in 54 countries. We used the 2016 World Bank classification to define two geoeconomic regions: middle-income countries (MICs) and high-income countries (HICs). ARDS was defined according to the Berlin criteria. Descriptive statistics were used to compare patients in MICs versus HICs. The primary outcome was the use of low tidal volume ventilation (LTVV) for the first 3 days of mechanical ventilation. Secondary outcomes were key ventilation parameters (tidal volume size, positive end-expiratory pressure, fraction of inspired oxygen, peak pressure, plateau pressure, driving pressure, and respiratory rate), patient characteristics, the risk for and actual development of acute respiratory distress syndrome after the first day of ventilation, duration of ventilation, ICU length of stay, and ICU mortality. Findings: Of the 7608 patients included in the original studies, this analysis included 3852 patients without ARDS, of whom 2345 were from MICs and 1507 were from HICs. Patients in MICs were younger, shorter and with a slightly lower body-mass index, more often had diabetes and active cancer, but less often chronic obstructive pulmonary disease and heart failure than patients from HICs. Sequential organ failure assessment scores were similar in MICs and HICs. Use of LTVV in MICs and HICs was comparable (42\ub74% vs 44\ub72%; absolute difference \u20131\ub769 [\u20139\ub758 to 6\ub711] p=0\ub767; data available in 3174 [82%] of 3852 patients). The median applied positive end expiratory pressure was lower in MICs than in HICs (5 [IQR 5\u20138] vs 6 [5\u20138] cm H2O; p=0\ub70011). ICU mortality was higher in MICs than in HICs (30\ub75% vs 19\ub79%; p=0\ub70004; adjusted effect 16\ub741% [95% CI 9\ub752\u201323\ub752]; p<0\ub70001) and was inversely associated with gross domestic product (adjusted odds ratio for a US$10 000 increase per capita 0\ub780 [95% CI 0\ub775\u20130\ub786]; p<0\ub70001). Interpretation: Despite similar disease severity and ventilation management, ICU mortality in patients without ARDS is higher in MICs than in HICs, with a strong association with country-level economic status. Funding: No funding

    Optimum time diversity for channels subject to pulse-burst interference

    No full text
    corecore