49 research outputs found

    Reliability of upright posture measurements in primary school children

    Get PDF
    BACKGROUND: Correct upright posture is considered to be a measure of good musculoskeletal health. Little is known about the usual variability of children's upright standing posture. The aim of this study was to assess differences between repeated measures of upright posture in a group of primary school children. METHODS: Sagittal plane photographs of usual, relaxed upright standing posture of 38 boys and girls aged 5–12 years were taken twice within an hour. Reflective markers were placed over the canthus, tragus, C7 spinous process, greater trochanter and lateral malleolus. Digitising software was used to calculate the x,y plane coordinates, from which five postural angles were calculated (trunk, neck, gaze, head on neck, lower limb). Height, weight, motor control estimates (as measured by the Brace Tests) and presence of recent pain were recorded for each child, and the association between the first test measure of posture angles and these factors was assessed using linear regression and ANOVA models. Multiple ANOVA models were applied to analyse the effect of repeated testing, and significant predictors on the angles. RESULTS: Four of the five postural angles (trunk, neck, head on neck, lower limb) were significantly influenced by age. As age was strongly associated with height (r(2 )= 0.84) and moderately associated with weight and motor control (r(2 )= 0.67, 0.56 respectively), these developmental parameters may well explain the age effect on angles. There was no relationship between age and pain reported on either the testing day, or recently, and there was no gender influence on any angle. There was no significant effect of repeated testing on any angle (ICC>0.93). None of the hypothesized predictors were associated with differences in angles from repeated testing. CONCLUSION: This study outlined the variability of relaxed upright standing posture of children aged 5–12 years, when measured twice in an hour. Age influenced the size of the angles but not the variability. While the subject numbers in this study are small, the findings provide useful information on which further studies in posture and its development in pre-adolescent children can be based

    Hitting sbottom in natural SUSY

    Get PDF
    We compare the experimental prospects of direct stop and sbottom pair production searches at the LHC. Such searches for stops are of great interest as they directly probe for states that are motivated by the SUSY solution to the hierarchy problem of the Higgs mass parameter - leading to a "Natural" SUSY spectrum. Noting that sbottom searches are less experimentally challenging and scale up in reach directly with the improvement on b-tagging algorithms, we discuss the interplay of small TeV scale custodial symmetry violation with sbottom direct pair production searches as a path to obtaining strong sub-TeV constraints on stops in a natural SUSY scenario. We argue that if a weak scale natural SUSY spectrum does not exist within the reach of LHC, then hopes for such a spectrum for large regions of parameter space should sbottom out. Conversely, the same arguments make clear that a discovery of such a spectrum is likely to proceed in a sbottom up manner.Comment: 18 pages, 8 figures,v2 refs added, JHEP versio

    Flavor Symmetric Sectors and Collider Physics

    Full text link
    We discuss the phenomenology of effective field theories with new scalar or vector representations of the Standard Model quark flavor symmetry group, allowing for large flavor breaking involving the third generation. Such field content can have a relatively low mass scale \lesssim TeV and O(1) couplings to quarks, while being naturally consistent with both flavor violating and flavor diagonal constraints. These theories therefore have the potential for early discovery at LHC, and provide a flavor safe "tool box" for addressing anomalies at colliders and low energy experiments. We catalogue the possible flavor symmetric representations, and consider applications to the anomalous Tevatron t-tbar forward backward asymmetry and B_s mixing measurements, individually or concurrently. Collider signatures and constraints on flavor symmetric models are also studied more generally. In our examination of the t-tbar forward backward asymmetry we determine model independent acceptance corrections appropriate for comparing against CDF data that can be applied to any model seeking to explain the t-tbar forward backward asymmetry.Comment: 71 pages, 14 Figures, 12 Table

    Clinimetric evaluation of active range of motion measures in patients with non-specific neck pain: a systematic review

    Get PDF
    The study is to provide a critical analysis of the research literature on clinimetric properties of instruments that can be used in daily practice to measure active cervical range of motion (ACROM) in patients with non-specific neck pain. A computerized literature search was performed in Medline, Cinahl and Embase from 1982 to January 2007. Two reviewers independently assessed the clinimetric properties of identified instruments using a criteria list. The search identified a total of 33 studies, investigating three different types of measurement instruments to determine ACROM. These instruments were: (1) different types of goniometers/inclinometers, (2) visual estimation, and (3) tape measurements. Intra- and inter-observer reliability was demonstrated for the cervical range of motion instrument (CROM), Cybex electronic digital instrument (EDI-320) and a single inclinometer. The presence of agreement was assessed for the EDI-320 and a single inclinometer. The CROM received a positive rating for construct validity. When clinical acceptability is taken into account both the CROM and the single inclinometer can be considered appropriate instruments for measuring the active range of motion in patients with non-specific neck pain in daily practice. Reliability is the aspect most frequently evaluated. Agreement, validity and responsiveness are documented less frequently

    NSUSY fits

    Get PDF
    We perform a global fit to Higgs signal-strength data in the context of light stops in Natural SUSY. In this case, the Wilson coefficients of the higher dimensional operators mediating g g -> h and h -> \gamma \gamma, given by c_g, c_\gamma, are related by c_g = 3 (1 + 3 \alpha_s/(2 \pi)) c_\gamma/8. We examine this predictive scenario in detail, combining Higgs signal-strength constraints with recent precision measurements of m_W, b-> s \gamma constraints and direct collider bounds on weak scale SUSY, finding regions of parameter space that are consistent with all of these constraints. However it is challenging for the allowed parameter space to reproduce the observed Higgs mass value with sub-TeV stops. We discuss some of the direct stop discovery prospects and show how global Higgs fits can be used to exclude light stop parameter space difficult to probe by direct collider searches. We determine the current status of such indirect exclusions and estimate their reach by the end of the 8 TeV LHC run.Comment: 41 pages, 13 figures. v3: final JHEP version, b to s gamma updated to latest data and typos correcte

    Multi-messenger observations of a binary neutron star merger

    Get PDF
    On 2017 August 17 a binary neutron star coalescence candidate (later designated GW170817) with merger time 12:41:04 UTC was observed through gravitational waves by the Advanced LIGO and Advanced Virgo detectors. The Fermi Gamma-ray Burst Monitor independently detected a gamma-ray burst (GRB 170817A) with a time delay of ~1.7 s with respect to the merger time. From the gravitational-wave signal, the source was initially localized to a sky region of 31 deg2 at a luminosity distance of 40+8-8 Mpc and with component masses consistent with neutron stars. The component masses were later measured to be in the range 0.86 to 2.26 Mo. An extensive observing campaign was launched across the electromagnetic spectrum leading to the discovery of a bright optical transient (SSS17a, now with the IAU identification of AT 2017gfo) in NGC 4993 (at ~40 Mpc) less than 11 hours after the merger by the One- Meter, Two Hemisphere (1M2H) team using the 1 m Swope Telescope. The optical transient was independently detected by multiple teams within an hour. Subsequent observations targeted the object and its environment. Early ultraviolet observations revealed a blue transient that faded within 48 hours. Optical and infrared observations showed a redward evolution over ~10 days. Following early non-detections, X-ray and radio emission were discovered at the transient’s position ~9 and ~16 days, respectively, after the merger. Both the X-ray and radio emission likely arise from a physical process that is distinct from the one that generates the UV/optical/near-infrared emission. No ultra-high-energy gamma-rays and no neutrino candidates consistent with the source were found in follow-up searches. These observations support the hypothesis that GW170817 was produced by the merger of two neutron stars in NGC4993 followed by a short gamma-ray burst (GRB 170817A) and a kilonova/macronova powered by the radioactive decay of r-process nuclei synthesized in the ejecta

    A randomized, comparative trial: does pillow type alter cervico-thoracic spinal posture when side lying?

    No full text
    Susan J Gordon1, Karen A Grimmer-Somers2, Patricia H Trott31School of Public Health, Tropical Medicine and Rehabilitation Science, James Cook University, Townsville, QLD; 2Centre for Allied Health Sciences, 3School of Health Sciences, University of South Australia, Adelaide, SA, AustraliaBackground: Many patients ask for advice about choosing a pillow. This research was undertaken to determine if pillow type alters cervico-thoracic spine position when resting in the side-lying position.Aim: To investigate the effect of different pillow shape and content on the slope of cervico-thoracic spine segments when side lying.Materials and methods: The study was a randomized blinded comparative trial set in a laboratory that replicated a bedroom. The subjects were side sleepers aged over 18 years. Exclusion criteria were history of surgery to the cervico-thoracic spine, an injury or accident to the cervico-thoracic spine in the preceding year, or currently receiving treatment for neck symptoms. Each participant rested in a standardized side-lying position for 10 minutes on each of the trial pillows: regular shaped polyester, foam, feather, and latex pillows, and a contour shaped foam pillow. Reflective markers were placed on external occipital protuberance (EOP), C2, C4, C7, and T3, and digital images were recorded of subjects at 0 and 10 minutes on each pillow. Images were digitized using each reflective marker and the slope of each spinal segment calculated. Univariate analysis of variance models were used to investigate slope differences between pillows at 0 and 10 minutes. Significance was established at P < 0.01 to take account of chance effects from repeated measures and multiple comparisons.Results: At 0 and 10 minutes, the EOP-C2, C2-C4, and C4-C7 segmental slopes were significantly different across all pillows. Significant differences were identified when comparing the feather pillow with the latex, regular and contour foam pillows, and when comparing the polyester and foam contour pillows. The regular and contour foam pillows produced similar slopes at all spinal segments.Conclusion: Cervico-thoracic spinal segment slope alters significantly when people change from a foam, latex, or polyester pillow to a feather pillow and vice versa. The shape of a foam pillow (contour versus regular shape) does not significantly alter cervico-thoracic spinal segment slope.Keywords: cervical spine, slope, spinal segment
    corecore