646 research outputs found

    Laser forming of fibre metal laminates

    Get PDF
    The laser forming process has been shown to be a viable method of shaping metallic components, as a means of rapid prototyping and of adjusting and aligning. Although the process does compete with conventional forming processes, applications are being discovered where laser forming alone can achieve the desired results. The application reported in this work demonstrates how the process can be used to form recently developed high strength fibre metal laminate materials. These materials due to their construction and high strength are difficult to form once constructed using conventional techniques. Fibre metal laminates are of particular interest to the aerospace industry, where the high strength yet lightweight construction of parts made with these materials offers significant weight reductions and hence a reduction in operational costs of new large commercial aircraft such as the Airbus A380. In addition a more recent application under investigation for these materials is in the construction of street furniture (e.g. litter bins) and airline cargo containers utilising their excellent blast resistance capabilities to save lives in the event of terrorism. © 2005 Old City Publishing, Inc

    Laser Forming of Aerospace Alloys

    Get PDF
    Non-contact forming by application of a thermal source has been known for some time. Recently, it has been shown that much greater controllability can be introduced by replacing the thermal source with a laser. This yields a process with strong potential for application in aerospace, including the rapid manufacture of prototypes and the adjustment of misaligned components. This paper briefly reviews the mechanisms involved in laser forming and then summarises experimental work carried out on aluminium alloys and titanium alloys that led to the development of a prototype system for the forming of 2-D sheet materials. Emphasis is placed on the process advantages, including the high accuracy (arising from the progressive nature of the process) that can be achieved in forming or adjustment of misalignment. Future work in a new collaborative programme to develop 3-D laser forming is summarised. Copyright © 2001 Society of Automotive Engineers, Inc

    Femtosecond laser internal structuring of materials using a spatial light modulator

    Get PDF
    Femtosecond laser pulses are of particular interest for internal modification of transperent materials as they enable nonlinear absorption due to the extremly high intensity in the focal volume. Since output from commercial laser sources currently exceeds single beam process requirements, parallel processing with multiple beams could provide a route to up-scaling processing speed and establish cost-effectiveness. The use of spatial light modulators, driven by fast computer-generated holograms for splitting a parent laser beam into a number of beamlets and digitally manipulate their positions and the laser intensity is demonstrated. With successful blocking of the zero order beam and subsequent focusing of the diffracted beams inside transperant materials, high throughput dynamic 2D/3D refractive index modification of polymer and glass substrates with a gain factor G > 20 has been achieved. Fundamental IR (775nm) femtosecond laser pulses were employed to produce optical components. For example, thick volume gratings written with more than 20 beams have 1st order diffraction efficiency η > 60%, indicating a refractive index change Δn ≈ 1.6x10-4. Characterization by microscopic examination and light coupling tests revealed the extent of resolution, process quality and assisted quantification of the process speed gain. The benefits and current limitations of this technique are discussed in detail

    The counselling self-estimate inventory (COSE): Does it work in Chinese counsellors?

    Get PDF
    Counselling self-efficacy is an important construct for research and evaluation in counsellors' competencies and training effectiveness. Larson et al. developed the Counselling Self-Estimate Inventory (COSE) for counsellors in America and examined its factor structure using exploratory factor analysis. They recommended a five-factor model (microskills, counselling process, difficult client behaviour, cultural competence, and awareness of values) and the use of the COSE for future research. However, little research has investigated the validity of the COSE in the context of counselling Chinese students in schools. In the present study, the factor structure of responses to the Chinese version of the Counselling Self-Estimate Inventory in a sample of 578 Hong Kong secondary school guidance teachers was examined using the EQS approach to confirmatory factor analysis. The results showed that while a five-factor model was fairly able to fit the data, the deletion of items related to the awareness of values factor yielded a better fitting model. The discussion of potential uses and limitations of the C-COSE in the context of preparing and supervising school guidance personnel in student counselling is relevant to counselling psychologists and researchers in Hong Kong and other parts of the world.postprin

    Effects of Intracoronary Alteplase on Microvascular Function in Acute Myocardial Infarction

    Get PDF
    Background—Impaired microcirculatory reperfusion worsens prognosis following acute ST‐segment–elevation myocardial infarction. In the T‐TIME (A Trial of Low‐Dose Adjunctive Alteplase During Primary PCI) trial, microvascular obstruction on cardiovascular magnetic resonance imaging did not differ with adjunctive, low‐dose, intracoronary alteplase (10 or 20 mg) versus placebo during primary percutaneous coronary intervention. We evaluated the effects of intracoronary alteplase, during primary percutaneous coronary intervention, on the index of microcirculatory resistance, coronary flow reserve, and resistive reserve ratio. Methods and Results—A prespecified physiology substudy of the T‐TIME trial. From 2016 to 2017, patients with ST‐segment–elevation myocardial infarction ≤6 hours from symptom onset were randomized in a double‐blind study to receive alteplase 20 mg, alteplase 10 mg, or placebo infused into the culprit artery postreperfusion, but prestenting. Index of microcirculatory resistance, coronary flow reserve, and resistive reserve ratio were measured after percutaneous coronary intervention. Cardiovascular magnetic resonance was performed at 2 to 7 days and 3 months. Analyses in relation to ischemic time (<2, 2–4, and ≥4 hours) were prespecified. One hundred forty‐four patients (mean age, 59±11 years; 80% male) were prospectively enrolled, representing 33% of the overall population (n=440). Overall, index of microcirculatory resistance (median, 29.5; interquartile range, 17.0–55.0), coronary flow reserve(1.4 [1.1–2.0]), and resistive reserve ratio (1.7 [1.3–2.3]) at the end of percutaneous coronary intervention did not differ between treatment groups. Interactions were observed between ischemic time and alteplase for coronary flow reserve (P=0.013), resistive reserve ratio (P=0.026), and microvascular obstruction (P=0.022), but not index of microcirculatory resistance. Conclusions—In ST‐segment–elevation myocardial infarction with ischemic time ≤6 hours, there was overall no difference in microvascular function with alteplase versus placebo

    Reliability of goniometric measurements in children with cerebral palsy: A comparative analysis of universal goniometer and electronic inclinometer. A pilot study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Even though technological progress has provided us with more and more sophisticated equipment for making goniometric measurements, the most commonly used clinical tools are still the universal goniometer and, to a lesser extent, the inclinometer. There is, however, no published study so far that uses an inclinometer for measurements in children with cerebral palsy (CP). The objective of this study was two-fold: to independently assess the intra and inter-examiner reliability for measuring the hip abduction range of motion in children with CP using two different instruments, the universal two-axis goniometer and electronic inclinometer. A pool of 5 examiners with different levels of experience as paediatric physiotherapists participated. The study did not compare both instruments because the measurement procedure and the hip position were different for each.</p> <p>Methods</p> <p>A prospective, observational study of goniometery was carried out with 14 lower extremities of 7 children with spastic CP. The inclinometer study was carried out with 8 lower extremities of 4 children with spastic CP. This study was divided into two independent parts: a study of the reliability of the hip abduction range of motion measured with a universal goniometer (hip at 0° flexion) and with an electronic inclinometer (hip at 90° flexion). The Intraclass Correlation Coefficient (ICC) was calculated to analyse intra and inter-examiner agreement for each instrument.</p> <p>Results</p> <p>For the goniometer, the intra-examiner reliability was excellent (>0.80), while the inter-examiner reliability was low (0.375 and 0.475). For the inclinometer, both the intra-examiner (0.850-0.975) and inter-examiner reliability were excellent (0.965 and 0.979).</p> <p>Conclusions</p> <p>The inter-examiner reliability for goniometric measurement of hip abduction in children with CP was low, in keeping with other results found in previous publications. The inclinometer has proved to be a highly reliable tool for measuring the hip abduction range of motion in children with CP, which opens up new possibilities in this field, despite having some measurement limitations.</p

    The complete sequences and gene organisation of the mitochondrial genomes of the heterodont bivalves Acanthocardia tuberculata and Hiatella arctica – and the first record for a putative Atpase subunit 8 gene in marine bivalves

    Get PDF
    BACKGROUND: Mitochondrial (mt) gene arrangement is highly variable among molluscs and especially among bivalves. Of the 30 complete molluscan mt-genomes published to date, only one is of a heterodont bivalve, although this is the most diverse taxon in terms of species numbers. We determined the complete sequence of the mitochondrial genomes of Acanthocardia tuberculata and Hiatella arctica, (Mollusca, Bivalvia, Heterodonta) and describe their gene contents and genome organisations to assess the variability of these features among the Bivalvia and their value for phylogenetic inference. RESULTS: The size of the mt-genome in Acanthocardia tuberculata is 16.104 basepairs (bp), and in Hiatella arctica 18.244 bp. The Acanthocardia mt-genome contains 12 of the typical protein coding genes, lacking the Atpase subunit 8 (atp8) gene, as all published marine bivalves. In contrast, a complete atp8 gene is present in Hiatella arctica. In addition, we found a putative truncated atp8 gene when re-annotating the mt-genome of Venerupis philippinarum. Both mt-genomes reported here encode all genes on the same strand and have an additional trnM. In Acanthocardia several large non-coding regions are present. One of these contains 3.5 nearly identical copies of a 167 bp motive. In Hiatella, the 3' end of the NADH dehydrogenase subunit (nad)6 gene is duplicated together with the adjacent non-coding region. The gene arrangement of Hiatella is markedly different from all other known molluscan mt-genomes, that of Acanthocardia shows few identities with the Venerupis philippinarum. Phylogenetic analyses on amino acid and nucleotide levels robustly support the Heterodonta and the sister group relationship of Acanthocardia and Venerupis. Monophyletic Bivalvia are resolved only by a Bayesian inference of the nucleotide data set. In all other analyses the two unionid species, being to only ones with genes located on both strands, do not group with the remaining bivalves. CONCLUSION: The two mt-genomes reported here add to and underline the high variability of gene order and presence of duplications in bivalve and molluscan taxa. Some genomic traits like the loss of the atp8 gene or the encoding of all genes on the same strand are homoplastic among the Bivalvia. These characters, gene order, and the nucleotide sequence data show considerable potential of resolving phylogenetic patterns at lower taxonomic levels

    Observation of associated near-side and away-side long-range correlations in √sNN=5.02  TeV proton-lead collisions with the ATLAS detector

    Get PDF
    Two-particle correlations in relative azimuthal angle (Δϕ) and pseudorapidity (Δη) are measured in √sNN=5.02  TeV p+Pb collisions using the ATLAS detector at the LHC. The measurements are performed using approximately 1  μb-1 of data as a function of transverse momentum (pT) and the transverse energy (ΣETPb) summed over 3.1<η<4.9 in the direction of the Pb beam. The correlation function, constructed from charged particles, exhibits a long-range (2<|Δη|<5) “near-side” (Δϕ∼0) correlation that grows rapidly with increasing ΣETPb. A long-range “away-side” (Δϕ∼π) correlation, obtained by subtracting the expected contributions from recoiling dijets and other sources estimated using events with small ΣETPb, is found to match the near-side correlation in magnitude, shape (in Δη and Δϕ) and ΣETPb dependence. The resultant Δϕ correlation is approximately symmetric about π/2, and is consistent with a dominant cos⁡2Δϕ modulation for all ΣETPb ranges and particle pT

    Measurements of fiducial and differential cross sections for Higgs boson production in the diphoton decay channel at s√=8 TeV with ATLAS

    Get PDF
    Measurements of fiducial and differential cross sections are presented for Higgs boson production in proton-proton collisions at a centre-of-mass energy of s√=8 TeV. The analysis is performed in the H → γγ decay channel using 20.3 fb−1 of data recorded by the ATLAS experiment at the CERN Large Hadron Collider. The signal is extracted using a fit to the diphoton invariant mass spectrum assuming that the width of the resonance is much smaller than the experimental resolution. The signal yields are corrected for the effects of detector inefficiency and resolution. The pp → H → γγ fiducial cross section is measured to be 43.2 ±9.4(stat.) − 2.9 + 3.2 (syst.) ±1.2(lumi)fb for a Higgs boson of mass 125.4GeV decaying to two isolated photons that have transverse momentum greater than 35% and 25% of the diphoton invariant mass and each with absolute pseudorapidity less than 2.37. Four additional fiducial cross sections and two cross-section limits are presented in phase space regions that test the theoretical modelling of different Higgs boson production mechanisms, or are sensitive to physics beyond the Standard Model. Differential cross sections are also presented, as a function of variables related to the diphoton kinematics and the jet activity produced in the Higgs boson events. The observed spectra are statistically limited but broadly in line with the theoretical expectations
    corecore