4,710 research outputs found

    Finasteride quantification in human plasma by high-performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry. application to a comparative pharmacokinetics study

    Get PDF
    A specific, fast and sensitive LC-MS/MS assay was developed for the determination of finasteride in human plasma using betamethsone dipropionate as the internal standard (IS). The limit of quantification was 1.0 ng/ml and the method was linear in the range of 1.0–25.0 ng/ml. The retention times were 0.75 min for finasteride and 0.85 min for IS. Method intra-batch precision and accuracy ranged from 3.6 to 7.1%, and 96.6 to 103.9%, respectively. Inter-batch precision ranged from 2.5 to 3.4%, while Inter-batch accuracy ranged from 100.3 to 103.5%. The analytical method was applied to evaluate the pharmacokinetic and relative bioavailability of 2 different pharmaceutical formulations containing 1.0 mg of finasteride. This study evaluated 38 volunteers in a randomized, 2-period crossover study with 7 days washout period between doses. The geometric mean and respective 90% CI of finasteride test/reference percent ratios were 95.68% (91.2 – 104.6%) for Cmax, 97.5% (92.1 –103.3%) for AUC0-t and 98.1 (92.67−103.8) for AUC0-inf. Based on the 90% confidence interval of the individual ratios (test formulation/reference formulation) for Cmax and AUC0-inf, it was concluded that the test formulation is bioequivalent to the reference one with respect to the rate and extent of absorption of finasteride65944945

    Janus kinase 2 regulates Bcr–Abl signaling in chronic myeloid leukemia

    Get PDF
    Despite the success of imatinib mesylate (IM) in the early chronic phase of chronic myeloid leukemia (CML), patients are resistant to IM and other kinase inhibitors in the later stages of CML. Our findings indicate that inhibition of Janus kinase 2 (Jak2) in Bcr–Abl+ cells overcomes IM resistance although the precise mechanism of Jak2 action is unknown. Knocking down Jak2 in Bcr–Abl+ cells reduced levels of the Bcr–Abl protein and also the phosphorylation of Tyr177 of Bcr–Abl, and Jak2 overexpression rescued these knockdown effects. Treatment of Bcr–Abl+ cells with Jak2 inhibitors for 4–6 h but not with IM also reduced Bcr–Abl protein and pTyr177 levels. In vitro kinase experiments performed with recombinant Jak2 showed that Jak2 readily phosphorylated Tyr177 of Bcr–Abl (a Jak2 consensus site, YvnV) whereas c-Abl did not. Importantly, Jak2 inhibition decreased pTyr177 Bcr–Abl in immune complexes but did not reduce levels of Bcr–Abl, suggesting that the reduction of Bcr–Abl by Jak2 inhibition is a separate event from phosphorylation of Tyr177. Jak2 inhibition by chemical inhibitors (TG101209/WP1193) and Jak2 knockdown diminished the activation of Ras, PI-3 kinase pathways and reduced levels of pTyrSTAT5. These findings suggest that Bcr–Abl stability and oncogenic signaling in CML cells are under the control of Jak2

    In-training assessment using direct observation of single-patient encounters: a literature review

    Get PDF
    We reviewed the literature on instruments for work-based assessment in single clinical encounters, such as the mini-clinical evaluation exercise (mini-CEX), and examined differences between these instruments in characteristics and feasibility, reliability, validity and educational effect. A PubMed search of the literature published before 8 January 2009 yielded 39 articles dealing with 18 different assessment instruments. One researcher extracted data on the characteristics of the instruments and two researchers extracted data on feasibility, reliability, validity and educational effect. Instruments are predominantly formative. Feasibility is generally deemed good and assessor training occurs sparsely but is considered crucial for successful implementation. Acceptable reliability can be achieved with 10 encounters. The validity of many instruments is not investigated, but the validity of the mini-CEX and the ‘clinical evaluation exercise’ is supported by strong and significant correlations with other valid assessment instruments. The evidence from the few studies on educational effects is not very convincing. The reports on clinical assessment instruments for single work-based encounters are generally positive, but supporting evidence is sparse. Feasibility of instruments seems to be good and reliability requires a minimum of 10 encounters, but no clear conclusions emerge on other aspects. Studies on assessor and learner training and studies examining effects beyond ‘happiness data’ are badly needed

    The Fluorescence Detector of the Pierre Auger Observatory

    Get PDF
    The Pierre Auger Observatory is a hybrid detector for ultra-high energy cosmic rays. It combines a surface array to measure secondary particles at ground level together with a fluorescence detector to measure the development of air showers in the atmosphere above the array. The fluorescence detector comprises 24 large telescopes specialized for measuring the nitrogen fluorescence caused by charged particles of cosmic ray air showers. In this paper we describe the components of the fluorescence detector including its optical system, the design of the camera, the electronics, and the systems for relative and absolute calibration. We also discuss the operation and the monitoring of the detector. Finally, we evaluate the detector performance and precision of shower reconstructions.Comment: 53 pages. Submitted to Nuclear Instruments and Methods in Physics Research Section

    Search for chargino-neutralino production with mass splittings near the electroweak scale in three-lepton final states in √s=13 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for supersymmetry through the pair production of electroweakinos with mass splittings near the electroweak scale and decaying via on-shell W and Z bosons is presented for a three-lepton final state. The analyzed proton-proton collision data taken at a center-of-mass energy of √s=13  TeV were collected between 2015 and 2018 by the ATLAS experiment at the Large Hadron Collider, corresponding to an integrated luminosity of 139  fb−1. A search, emulating the recursive jigsaw reconstruction technique with easily reproducible laboratory-frame variables, is performed. The two excesses observed in the 2015–2016 data recursive jigsaw analysis in the low-mass three-lepton phase space are reproduced. Results with the full data set are in agreement with the Standard Model expectations. They are interpreted to set exclusion limits at the 95% confidence level on simplified models of chargino-neutralino pair production for masses up to 345 GeV

    Measurements of fiducial and differential cross sections for Higgs boson production in the diphoton decay channel at s√=8 TeV with ATLAS

    Get PDF
    Measurements of fiducial and differential cross sections are presented for Higgs boson production in proton-proton collisions at a centre-of-mass energy of s√=8 TeV. The analysis is performed in the H → γγ decay channel using 20.3 fb−1 of data recorded by the ATLAS experiment at the CERN Large Hadron Collider. The signal is extracted using a fit to the diphoton invariant mass spectrum assuming that the width of the resonance is much smaller than the experimental resolution. The signal yields are corrected for the effects of detector inefficiency and resolution. The pp → H → γγ fiducial cross section is measured to be 43.2 ±9.4(stat.) − 2.9 + 3.2 (syst.) ±1.2(lumi)fb for a Higgs boson of mass 125.4GeV decaying to two isolated photons that have transverse momentum greater than 35% and 25% of the diphoton invariant mass and each with absolute pseudorapidity less than 2.37. Four additional fiducial cross sections and two cross-section limits are presented in phase space regions that test the theoretical modelling of different Higgs boson production mechanisms, or are sensitive to physics beyond the Standard Model. Differential cross sections are also presented, as a function of variables related to the diphoton kinematics and the jet activity produced in the Higgs boson events. The observed spectra are statistically limited but broadly in line with the theoretical expectations

    Update on the correlation of the highest energy cosmic rays with nearby extragalactic matter

    Get PDF
    Data collected by the Pierre Auger Observatory through 31 August 2007 showed evidence for anisotropy in the arrival directions of cosmic rays above the Greisen-Zatsepin-Kuz'min energy threshold, \nobreak{6×10196\times 10^{19}eV}. The anisotropy was measured by the fraction of arrival directions that are less than 3.13.1^\circ from the position of an active galactic nucleus within 75 Mpc (using the V\'eron-Cetty and V\'eron 12th12^{\rm th} catalog). An updated measurement of this fraction is reported here using the arrival directions of cosmic rays recorded above the same energy threshold through 31 December 2009. The number of arrival directions has increased from 27 to 69, allowing a more precise measurement. The correlating fraction is (386+7)(38^{+7}_{-6})%, compared with 2121% expected for isotropic cosmic rays. This is down from the early estimate of (6913+11)(69^{+11}_{-13})%. The enlarged set of arrival directions is examined also in relation to other populations of nearby extragalactic objects: galaxies in the 2 Microns All Sky Survey and active galactic nuclei detected in hard X-rays by the Swift Burst Alert Telescope. A celestial region around the position of the radiogalaxy Cen A has the largest excess of arrival directions relative to isotropic expectations. The 2-point autocorrelation function is shown for the enlarged set of arrival directions and compared to the isotropic expectation.Comment: Accepted for publication in Astroparticle Physics on 31 August 201
    corecore