937 research outputs found

    Novel Green Micro-Synthesis of Graphene-Titanium Dioxide Nano- Composites with Photo-Electrochemical Properties

    Get PDF
    Background: Graphene-Titanium dioxide nano-composite forms a very promising material in the field of photo-electrochemical research. Methods: In this study, a novel environment-friendly synthesis method was developed to produce well-distributed anatase nano-titanium dioxide spherical particles on the surface of graphene sheets. This novel method has great advantages over previously developed methods of producing graphenetitanium dioxide nanocomposites (GTNCs). High calcination temperature 650°C was used in the preparation of nano titanium dioxide, and chemical exfoliation for graphene synthesis and GTNC was performed by our novel method of depositing titanium dioxide nanoparticles on graphene sheets using a Y-shaped micro-reactor under a controlled pumping rate with minimal use of chemicals. Results: The physiochemical and crystallographic properties of the GTNC were confirmed by TEM, XRD, FTIR and EDX measurements, confirming process repeatability. Spherical nano-titanium dioxide was produced in the anatase phase with very high crystallinity and small particle diameters ranging from 9 nm to 25 nm, also the as prepared graphene (RGO) exhibited minimal flake folding and a high carbon content of 81.28% with a low oxygen-to-carbon atomic ratio of 0.172 and GTNCs produced by our novel method had a superior loading content, a homogeneous distribution and a 96.6% higher content of titanium dioxide particles on the graphene sheets compared with GTNCs prepared with the one-pot method. Conclusion: For its photoelectrochemical properties, chronoamperometry showed that GTNC sample (2) had a higher peak current of 60 μA compared with that of GTNC sample (1), which indicates that the separation and transfer of electron-hole pairs are better in the case of GTNC sample (2) and according to the LSV results, the generation of photocurrent in the samples can be observed through multiple on-off cycles, which indicates that the electrodes are stable and that the photocurrent is quite reversible

    Efficient Multimodal Deep-Learning-Based COVID-19 Diagnostic System for Noisy and Corrupted Images

    Get PDF
    Introduction: In humanity\u27s ongoing fight against its common enemy of COVID-19, researchers have been relentless in finding efficient technologies to support mitigation, diagnosis, management, contact tracing, and ultimately vaccination. Objectives: Engineers and computer scientists have deployed the potent properties of deep learning models (DLMs) in COVID-19 detection and diagnosis. However, publicly available datasets are often adulterated during collation, transmission, or storage. Meanwhile, inadequate, and corrupted data are known to impact the learnability and efficiency of DLMs. Methods: This study focuses on enhancing previous efforts via two multimodal diagnostic systems to extract required features for COVID-19 detection using adulterated chest X-ray images. Our proposed DLM consists of a hierarchy of convolutional and pooling layers that are combined to support efficient COVID-19 detection using chest X-ray images. Additionally, a batch normalization layer is used to curtail overfitting that usually arises from the convolution and pooling (CP) layers. Results: In addition to matching the performance of standard techniques reported in the literature, our proposed diagnostic systems attain an average accuracy of 98% in the detection of normal, COVID-19, and viral pneumonia cases using corrupted and noisy images. Conclusions: Such robustness is crucial for real-world applications where data is usually unavailable, corrupted, or adulterated

    Diagnostic accuracy of ultrasonography compared to unenhanced CT for stone and obstruction in patients with renal failure

    Get PDF
    BACKGROUND: To determine accuracy of ultrasound (US) kidney, ureter and bladder (KUB) compared to un-enhanced helical CT (UHCT) in patients with renal failure in the diagnosis of stone and obstruction. METHODS: This is a case controlled study conducted in the period from June 2000 to July 2003 at a university hospital. All patients had both US and UHCT scan. Patients with serum creatinine ≥ 1.8 mg/dl were included in the study. Only direct visualization of stone was considered as confirmatory. In both the studies, UHCT and US, presence of stone and obstruction were noted. The relevant biochemicals, radiological and clinical records of all the patients were analyzed. Data was analyzed using commercially available software. RESULTS: During the period of study 864 patients had UHCT for evaluation of the urinary tract in patients presenting with flank pain. Out of these 34 patients had both UHCT and US done within a span of one day and had serum creatinine of ≥1.8 mg/dl. Mean age was 48 ±15.8 years and 59% of patients were males. UHCT identified renal stones in 21 (62%), whereas 17 of these were identified on US, with a sensitivity of 81%. Of the four patients with renal stones missed on US, three were identified on plain x-ray; the mean size of stones missed was 6.3 mm. Of the 22 (65%) patients with ureteric stone on UHCT, US could only identify 10; a further 7 were identified on x-ray KUB, giving a sensitivity of 45% (US alone) and 77% (US with x-ray KUB). CONCLUSIONS: US is sensitive and specific for renal stones, 81% and 100% and for hydronephrosis, 93% and 100%, respectively. Its sensitivity to pick ureteric stone (46%) and to identify hydroureter (50%) is low. Addition of x-ray KUB abdomen increases the sensitivity for ureteric stones to 77%

    Antimicrobial resistance among migrants in Europe: a systematic review and meta-analysis

    Get PDF
    BACKGROUND: Rates of antimicrobial resistance (AMR) are rising globally and there is concern that increased migration is contributing to the burden of antibiotic resistance in Europe. However, the effect of migration on the burden of AMR in Europe has not yet been comprehensively examined. Therefore, we did a systematic review and meta-analysis to identify and synthesise data for AMR carriage or infection in migrants to Europe to examine differences in patterns of AMR across migrant groups and in different settings. METHODS: For this systematic review and meta-analysis, we searched MEDLINE, Embase, PubMed, and Scopus with no language restrictions from Jan 1, 2000, to Jan 18, 2017, for primary data from observational studies reporting antibacterial resistance in common bacterial pathogens among migrants to 21 European Union-15 and European Economic Area countries. To be eligible for inclusion, studies had to report data on carriage or infection with laboratory-confirmed antibiotic-resistant organisms in migrant populations. We extracted data from eligible studies and assessed quality using piloted, standardised forms. We did not examine drug resistance in tuberculosis and excluded articles solely reporting on this parameter. We also excluded articles in which migrant status was determined by ethnicity, country of birth of participants' parents, or was not defined, and articles in which data were not disaggregated by migrant status. Outcomes were carriage of or infection with antibiotic-resistant organisms. We used random-effects models to calculate the pooled prevalence of each outcome. The study protocol is registered with PROSPERO, number CRD42016043681. FINDINGS: We identified 2274 articles, of which 23 observational studies reporting on antibiotic resistance in 2319 migrants were included. The pooled prevalence of any AMR carriage or AMR infection in migrants was 25·4% (95% CI 19·1-31·8; I2 =98%), including meticillin-resistant Staphylococcus aureus (7·8%, 4·8-10·7; I2 =92%) and antibiotic-resistant Gram-negative bacteria (27·2%, 17·6-36·8; I2 =94%). The pooled prevalence of any AMR carriage or infection was higher in refugees and asylum seekers (33·0%, 18·3-47·6; I2 =98%) than in other migrant groups (6·6%, 1·8-11·3; I2 =92%). The pooled prevalence of antibiotic-resistant organisms was slightly higher in high-migrant community settings (33·1%, 11·1-55·1; I2 =96%) than in migrants in hospitals (24·3%, 16·1-32·6; I2 =98%). We did not find evidence of high rates of transmission of AMR from migrant to host populations. INTERPRETATION: Migrants are exposed to conditions favouring the emergence of drug resistance during transit and in host countries in Europe. Increased antibiotic resistance among refugees and asylum seekers and in high-migrant community settings (such as refugee camps and detention facilities) highlights the need for improved living conditions, access to health care, and initiatives to facilitate detection of and appropriate high-quality treatment for antibiotic-resistant infections during transit and in host countries. Protocols for the prevention and control of infection and for antibiotic surveillance need to be integrated in all aspects of health care, which should be accessible for all migrant groups, and should target determinants of AMR before, during, and after migration. FUNDING: UK National Institute for Health Research Imperial Biomedical Research Centre, Imperial College Healthcare Charity, the Wellcome Trust, and UK National Institute for Health Research Health Protection Research Unit in Healthcare-associated Infections and Antimictobial Resistance at Imperial College London

    Search for New Physics with Jets and Missing Transverse Momentum in pp collisions at sqrt(s) = 7 TeV

    Get PDF
    A search for new physics is presented based on an event signature of at least three jets accompanied by large missing transverse momentum, using a data sample corresponding to an integrated luminosity of 36 inverse picobarns collected in proton--proton collisions at sqrt(s)=7 TeV with the CMS detector at the LHC. No excess of events is observed above the expected standard model backgrounds, which are all estimated from the data. Exclusion limits are presented for the constrained minimal supersymmetric extension of the standard model. Cross section limits are also presented using simplified models with new particles decaying to an undetected particle and one or two jets

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns
    corecore