29 research outputs found

    Long Range Plan: Dense matter theory for heavy-ion collisions and neutron stars

    Full text link
    Since the release of the 2015 Long Range Plan in Nuclear Physics, major events have occurred that reshaped our understanding of quantum chromodynamics (QCD) and nuclear matter at large densities, in and out of equilibrium. The US nuclear community has an opportunity to capitalize on advances in astrophysical observations and nuclear experiments and engage in an interdisciplinary effort in the theory of dense baryonic matter that connects low- and high-energy nuclear physics, astrophysics, gravitational waves physics, and data scienceComment: 70 pages, 3 figures, White Paper for the Long Range Plan for Nuclear Scienc

    Multi-messenger observations of a binary neutron star merger

    Get PDF
    On 2017 August 17 a binary neutron star coalescence candidate (later designated GW170817) with merger time 12:41:04 UTC was observed through gravitational waves by the Advanced LIGO and Advanced Virgo detectors. The Fermi Gamma-ray Burst Monitor independently detected a gamma-ray burst (GRB 170817A) with a time delay of ~1.7 s with respect to the merger time. From the gravitational-wave signal, the source was initially localized to a sky region of 31 deg2 at a luminosity distance of 40+8-8 Mpc and with component masses consistent with neutron stars. The component masses were later measured to be in the range 0.86 to 2.26 Mo. An extensive observing campaign was launched across the electromagnetic spectrum leading to the discovery of a bright optical transient (SSS17a, now with the IAU identification of AT 2017gfo) in NGC 4993 (at ~40 Mpc) less than 11 hours after the merger by the One- Meter, Two Hemisphere (1M2H) team using the 1 m Swope Telescope. The optical transient was independently detected by multiple teams within an hour. Subsequent observations targeted the object and its environment. Early ultraviolet observations revealed a blue transient that faded within 48 hours. Optical and infrared observations showed a redward evolution over ~10 days. Following early non-detections, X-ray and radio emission were discovered at the transient’s position ~9 and ~16 days, respectively, after the merger. Both the X-ray and radio emission likely arise from a physical process that is distinct from the one that generates the UV/optical/near-infrared emission. No ultra-high-energy gamma-rays and no neutrino candidates consistent with the source were found in follow-up searches. These observations support the hypothesis that GW170817 was produced by the merger of two neutron stars in NGC4993 followed by a short gamma-ray burst (GRB 170817A) and a kilonova/macronova powered by the radioactive decay of r-process nuclei synthesized in the ejecta

    Diving below the spin-down limit:constraints on gravitational waves from the energetic young pulsar PSR J0537-6910

    Get PDF
    We present a search for continuous gravitational-wave signals from the young, energetic X-ray pulsar PSR J0537-6910 using data from the second and third observing runs of LIGO and Virgo. The search is enabled by a contemporaneous timing ephemeris obtained using NICER data. The NICER ephemeris has also been extended through 2020 October and includes three new glitches. PSR J0537-6910 has the largest spin-down luminosity of any pulsar and is highly active with regards to glitches. Analyses of its long-term and inter-glitch braking indices provided intriguing evidence that its spin-down energy budget may include gravitational-wave emission from a time-varying mass quadrupole moment. Its 62 Hz rotation frequency also puts its possible gravitational-wave emission in the most sensitive band of LIGO/Virgo detectors. Motivated by these considerations, we search for gravitational-wave emission at both once and twice the rotation frequency. We find no signal, however, and report our upper limits. Assuming a rigidly rotating triaxial star, our constraints reach below the gravitational-wave spin-down limit for this star for the first time by more than a factor of two and limit gravitational waves from the l = m = 2 mode to account for less than 14% of the spin-down energy budget. The fiducial equatorial ellipticity is limited to less than about 3 x 10⁻⁵, which is the third best constraint for any young pulsar

    Observation of Gravitational Waves from Two Neutron Star–Black Hole Coalescences

    Get PDF
    Abstract: We report the observation of gravitational waves from two compact binary coalescences in LIGO’s and Virgo’s third observing run with properties consistent with neutron star–black hole (NSBH) binaries. The two events are named GW200105_162426 and GW200115_042309, abbreviated as GW200105 and GW200115; the first was observed by LIGO Livingston and Virgo and the second by all three LIGO–Virgo detectors. The source of GW200105 has component masses 8.9−1.5+1.2 and 1.9−0.2+0.3M⊙ , whereas the source of GW200115 has component masses 5.7−2.1+1.8 and 1.5−0.3+0.7M⊙ (all measurements quoted at the 90% credible level). The probability that the secondary’s mass is below the maximal mass of a neutron star is 89%–96% and 87%–98%, respectively, for GW200105 and GW200115, with the ranges arising from different astrophysical assumptions. The source luminosity distances are 280−110+110 and 300−100+150Mpc , respectively. The magnitude of the primary spin of GW200105 is less than 0.23 at the 90% credible level, and its orientation is unconstrained. For GW200115, the primary spin has a negative spin projection onto the orbital angular momentum at 88% probability. We are unable to constrain the spin or tidal deformation of the secondary component for either event. We infer an NSBH merger rate density of 45−33+75Gpc−3yr−1 when assuming that GW200105 and GW200115 are representative of the NSBH population or 130−69+112Gpc−3yr−1 under the assumption of a broader distribution of component masses

    Superselective microcoil embolization of a traumatic pseudoaneurysm of the cavernosal artery

    No full text
    According to the literature, straddle injuries of the perineum may result in arteriosinusoidal fistula and secondary high-flow priapism, We report a case of a 23-year-old man who developed a traumatic pseudoaneurysm of the cavernosal artery, secondary to straddle injury, and presented with painless priapism, It was treated successfully with superselective microcoil embolization and the priapism resolved, Copyright (C) 2000 S. Karger AG, Basel

    Preoperative embolization of bone metastases from renal cell carcinoma

    No full text
    The purpose of this study was to correlate the effectiveness of preoperative embolization with the blood loss and transfusion requirement during surgery for bone metastases from renal cell carcinonoma. Twenty-eight preoperative embolizations in 26 patients with renal cell carcinoma metastatic to bone were retrospectively evaluated and divided into two groups: Group A included the embolizations that resulted in complete devascularization of the lesion as defined by the post-embolization arteriograms, and group B included those with an incomplete result. The two groups were compared with regard to blood loss and transfusion requirement during surgery, by unpaired two-tailed Student’s t-test. Where complete embolization was effected (group A, 10 cases), there was a mean blood loss of 535 +/- 390 ml. When a less than complete embolization was achieved (group B, cases), the mean blood loss was 1.247 +/- 1.047 ml (p = 0.049). The red blood cell transfusion in group A was 1.3 +/- 1 units, whereas in group B it was 2.4 +/- 1.2 (p = 0.03). Preoperative embolization of bone metastases from renal cell carcinoma with subsequent complete devascularization leads to significant reduction of blood loss during surgery. Interventional radiologists should pursue and embolize every feeder to the metastasis, because any less than complete devascularization increases the amount of blood loss and the amount of red blood cell transfusion during surgery
    corecore