55 research outputs found

    Creative destruction in science

    Get PDF
    Drawing on the concept of a gale of creative destruction in a capitalistic economy, we argue that initiatives to assess the robustness of findings in the organizational literature should aim to simultaneously test competing ideas operating in the same theoretical space. In other words, replication efforts should seek not just to support or question the original findings, but also to replace them with revised, stronger theories with greater explanatory power. Achieving this will typically require adding new measures, conditions, and subject populations to research designs, in order to carry out conceptual tests of multiple theories in addition to directly replicating the original findings. To illustrate the value of the creative destruction approach for theory pruning in organizational scholarship, we describe recent replication initiatives re-examining culture and work morality, working parents\u2019 reasoning about day care options, and gender discrimination in hiring decisions. Significance statement It is becoming increasingly clear that many, if not most, published research findings across scientific fields are not readily replicable when the same method is repeated. Although extremely valuable, failed replications risk leaving a theoretical void\u2014 reducing confidence the original theoretical prediction is true, but not replacing it with positive evidence in favor of an alternative theory. We introduce the creative destruction approach to replication, which combines theory pruning methods from the field of management with emerging best practices from the open science movement, with the aim of making replications as generative as possible. In effect, we advocate for a Replication 2.0 movement in which the goal shifts from checking on the reliability of past findings to actively engaging in competitive theory testing and theory building. Scientific transparency statement The materials, code, and data for this article are posted publicly on the Open Science Framework, with links provided in the article

    Examining the generalizability of research findings from archival data

    Get PDF
    This initiative examined systematically the extent to which a large set of archival research findings generalizes across contexts. We repeated the key analyses for 29 original strategic management effects in the same context (direct reproduction) as well as in 52 novel time periods and geographies; 45% of the reproductions returned results matching the original reports together with 55% of tests in different spans of years and 40% of tests in novel geographies. Some original findings were associated with multiple new tests. Reproducibility was the best predictor of generalizability—for the findings that proved directly reproducible, 84% emerged in other available time periods and 57% emerged in other geographies. Overall, only limited empirical evidence emerged for context sensitivity. In a forecasting survey, independent scientists were able to anticipate which effects would find support in tests in new samples

    Minimal information for studies of extracellular vesicles 2018 (MISEV2018):a position statement of the International Society for Extracellular Vesicles and update of the MISEV2014 guidelines

    Get PDF
    The last decade has seen a sharp increase in the number of scientific publications describing physiological and pathological functions of extracellular vesicles (EVs), a collective term covering various subtypes of cell-released, membranous structures, called exosomes, microvesicles, microparticles, ectosomes, oncosomes, apoptotic bodies, and many other names. However, specific issues arise when working with these entities, whose size and amount often make them difficult to obtain as relatively pure preparations, and to characterize properly. The International Society for Extracellular Vesicles (ISEV) proposed Minimal Information for Studies of Extracellular Vesicles (“MISEV”) guidelines for the field in 2014. We now update these “MISEV2014” guidelines based on evolution of the collective knowledge in the last four years. An important point to consider is that ascribing a specific function to EVs in general, or to subtypes of EVs, requires reporting of specific information beyond mere description of function in a crude, potentially contaminated, and heterogeneous preparation. For example, claims that exosomes are endowed with exquisite and specific activities remain difficult to support experimentally, given our still limited knowledge of their specific molecular machineries of biogenesis and release, as compared with other biophysically similar EVs. The MISEV2018 guidelines include tables and outlines of suggested protocols and steps to follow to document specific EV-associated functional activities. Finally, a checklist is provided with summaries of key points

    Proceedings of the Thirteenth International Society of Sports Nutrition (ISSN) Conference and Expo

    Get PDF
    Meeting Abstracts: Proceedings of the Thirteenth International Society of Sports Nutrition (ISSN) Conference and Expo Clearwater Beach, FL, USA. 9-11 June 201

    The Video Head Impulse Test: Normal Reference Intervals & Test-Retest Reliability

    No full text
    The purpose of this presentation is to describe the normal reference intervals and the intra- and inter-examiner reliability for horizontal VOR gain obtained with two different video head impulse test devices in young normal adult participants

    Normative Data and Test-Retest Reliability of the SYNAPSYS Video Head Impulse Test

    No full text
    Background: The observation or measurement of eye movement can aid in the detection and localization of vestibular pathology due to the relationship between the function of the vestibular sensory receptors in the inner ear and the eye movements produced by the vestibulo-ocular reflex (VOR). The majority of bedside and laboratory tests of vestibular function involve the observation or measurement of horizontal eye movements (i.e., horizontal VOR) produced by stimuli that activate the horizontal semicircular canals (SCCs) and the superior vestibular nerve. The video head impulse test (vHIT) is a new clinical test of dynamic SCC function that uses a high-speed digital video camera to record head and eye movement during and immediately after passive head rotations. The SYNAPSYS Inc. vHIT device measures the “canal deficit” (deviation in gaze) during passive head impulses in the horizontal and diagonal (vertical) planes. There is, however, a paucity of data that has been reported using this device. Purpose: The purpose of this study was to obtain normative data and assess the test-retest reliability of the SYNAPSYS vHIT (version 2.0). Research Design: A prospective repeated measures design was utilized. Study Sample: Thirty young adults with normal hearing, normal caloric test results, and a negative history of vestibular disorder, neurological disease, open or closed head injury, or cervical spine injury participated in the study. Data Collection and Analysis: A single examiner manually rotated each participant’s head in the horizontal and diagonal planes in two directions (left and right in the horizontal plane; downward and upward in each diagonal plane) resulting in the stimulation of each of the six SCCs. Each participant returned for repeat testing to assess test-retest reliability. The effects of ear, session, and semicircular canal (horizontal, anterior, posterior) on the magnitude of canal deficit during the vHIT were assessed using repeated measures analysis of variance. Results: The mean canal deficit of the horizontal canals (8.3%) was significantly lower than the mean canal deficit of the anterior canals (16.5%) and the posterior canals (15.2%); there was no significant difference between the mean canal deficits of the anterior and posterior canals. The main effects of session and ear on canal deficit were not significant, and there were no significant interaction effects. There was no significant difference between the mean canal deficit for session 1 and session 2 for the horizontal, anterior, and posterior canals. The 95th percentiles for canal deficit were 19, 26, and 22% for the horizontal, anterior, and posterior SCCs, respectively. Conclusions: Testing of all six SCCs was completed in most participants in ∼10 min and was well-tolerated. The vHIT has some important advantages relative to more established laboratory tests of horizontal SCC function including the ability to assess the vertical SCCs, lower cost, shorter test time, greater portability, minimal space requirements, and increased patient comfort. Additional data, however, should be obtained from older participants with normal vestibular function and from patients with vestibular disorders. Within-subject comparisons between the results of the vHIT and the caloric and rotary chair tests will be important in determining the role of the vHIT in the vestibular test battery

    Effects of Stimulus and Recording Parameters on the Air Conduction Ocular Vestibular Evoked Myogenic Potential

    No full text
    Background: Vestibular evoked myogenic potentials (VEMPs) have been recorded from the sternocleidomastoid muscle (cervical VEMP or cVEMP) and more recently from the eye muscles (ocular VEMP or oVEMP) in response to air conduction and bone conduction stimuli. Both cVEMPs and oVEMPs are mediated by the otoliths and thereby provide diagnostic information that is complementary to videonystagmography and rotational chair tests. In contrast to the air conduction cVEMP, which originates from the saccule/inferior vestibular nerve, recent evidence suggests the possibility that the air conduction oVEMP may be mediated by the utricle/superior vestibular nerve. The oVEMP, therefore, may provide complementary diagnostic information relative to the cVEMP. There are relatively few studies, however, that have quantified the effects of stimulus and recording parameters on the air conduction oVEMP, and there is a paucity of normative data. Purpose: To evaluate the effects of several stimulus and recording parameters on the air conduction oVEMP and to establish normative data for clinical use. Research Design: A prospective repeated measures design was utilized. Study Sample: Forty-seven young adults with no history of neurologic disease, hearing loss, middle ear pathology, open or closed head injury, cervical injury, or audiovestibular disorder participated in the study. Data Collection and Analysis: The effects of stimulus frequency, stimulus level, gaze elevation, and recording electrode location on the amplitude and latency of the oVEMP for monaural air conduction stimuli were assessed using repeated measures analyses of variance in an initial group of 17 participants. The optimal stimulus and recording parameters obtained in the initial group were used subsequently to obtain oVEMPs from 30 additional participants. Results: The effects of stimulus frequency, stimulus level, gaze elevation, and electrode location on the response prevalence, amplitude, and latency of the oVEMP for monaural air conduction stimuli were significant. The maximum N1-P1 amplitude and response prevalence were obtained for contralateral oVEMPs using a 500 Hz tone burst presented at 125 dB peak SPL during upward gaze at an elevation of 30°. Conclusions: The optimal stimulus and recording parameters quantified in this study were used to establish normative data that may be useful for the clinical application of the air conduction oVEMP

    The Video Head Impulse Test

    No full text
    corecore