1,025 research outputs found

    A procedure for optimal calibration for a QCM electronic nose. Relation with specifications for pear quality.

    Get PDF
    The “Rome Tor Vergata” electronic nose has eight Quartz Microbalance Sensors. When a mass is absorbed or placed onto the quartz crystal surface, the oscillation frequency changes in proportion to the amount of mass. Despite previous studies, no QCM calibration statement has been made in relation to the sensitivity needed in the sensors for pear quality assessment. A calibration procedure has been designed and precision, sensitivity, specificity and reproducibility, on a QCM based electronic nose, evaluated. Using data of emission for pear, determinated by GC, it has been evaluated the extracted metrology features in relation to the specifications of the sensing device needed for quality assessment in pears

    Cholecystokinin in the central nervous system of the sea lamprey Petromyzon marinus: precursor identification and neuroanatomical relationships with other neuronal signalling systems

    Get PDF
    Cholecystokinin (CCK) is a neuropeptide that modulates processes such as digestion, satiety, and anxiety. CCK-type peptides have been characterized in jawed vertebrates and invertebrates, but little is known about CCK-type signalling in the most ancient group of vertebrates, the agnathans. Here, we have cloned and sequenced a cDNA encoding a sea lamprey (Petromyzon marinus L.) CCK-type precursor (PmCCK), which contains a CCK-type octapeptide sequence (PmCCK-8) that is highly similar to gnathostome CCKs. Using mRNA in situ hybridization, the distribution of PmCCK-expressing neurons was mapped in the CNS of P. marinus. This revealed PmCCK-expressing neurons in the hypothalamus, posterior tubercle, prethalamus, nucleus of the medial longitudinal fasciculus, midbrain tegmentum, isthmus, rhombencephalic reticular formation, and the putative nucleus of the solitary tract. Some PmCCK-expressing neuronal populations were only observed in adults, revealing important differences with larvae. We generated an antiserum to PmCCK-8 to enable immunohistochemical analysis of CCK expression, which revealed that GABA or glutamate, but not serotonin, tyrosine hydroxylase or neuropeptide Y, is co-expressed in some PmCCK-8-immunoreactive (ir) neurons. Importantly, this is the first demonstration of co-localization of GABA and CCK in neurons of a non-mammalian vertebrate. We also characterized extensive cholecystokinergic fibre systems of the CNS, including innervation of habenular subnuclei. A conspicuous PmCCK-8-ir tract ascending in the lateral rhombencephalon selectively innervates a glutamatergic population in the dorsal isthmic grey. Interestingly, this tract is reminiscent of the secondary gustatory/visceral tract of teleosts. In conclusion, this study provides important new information on the evolution of the cholecystokinergic system in vertebrates.</p

    Prospective of Innovative Technologies for Quality Supervision and Classification of Roasted Coffee Beans

    Get PDF
    Color sorting is the major procedure employed for establish roast degree of coffee beans. However, color-based procedures have been proven to be ineffective, since coffee beans roasted to different degrees can present the same average readings in light reflectance measurements with significant quality variations. Besides to color, other major changes in beans are volume (swell), mass, form, bean pop and density. Eight samples of arabica coffee from Colombia and Guatemala have been roasted under slightly different conditions of time and temperature in order to obtain the same color classification. Sample analysis of data from nuclear magnetic resonance relaxometry show differences between samples in T1 and T2 parameters at cellular and subcellular level, and image analysis carried out on X-ray μCT leading to microestruture images corroborate differences in porosity and fissures presence among them, proving the potentiality of these technological solutions for sensing the microstructure of coffee to provide tools to enhance the roasting process

    Spinal cord RNA-seq data after a baclofen treatment in mice with a spinal cord injury

    Get PDF
    Spinal cord injury (SCI) leads to severe functional deficits. Currently, there are no available pharmacological treatments to promote neurological recovery in SCI patients. Recent work from our group has shown that a baclofen treatment can promote functional recovery after a compression SCI in mice [1]. Here, we provide transcriptomic (RNA-seq) data from adult mouse spinal cords collected 7 days after a compression SCI and baclofen (vs vehicle) administration. The Illumina NovaSeq 6000 platform was used to generate the raw transcriptomic data. In addition, we also present bioinformatic analyses including differential gene expression analysis, enrichment analyses for various functional annotations (gene ontology, KEGG and BioCarta pathways or InterPro domains) and transcription factor targets. The raw RNA-seq data has been uploaded to the NCBI Sequence Read Archive (SRA) database (Bioproject ID PRJNA886048). The data generated from the bioinformatic analyses is contained within the articleThis work was supported by the Wings for Life Spinal Cord Research Foundation (grant reference WFL-ES-03/19), the Portuguese Foundation for Science and Technology (FCT) EXPL/MED-FAR/1529/2021 to N. de Sousa and through the Scientific Employment Stimulus to N. Silva and S. Monteiro (CEECIND/04794/2017 and CEECIND/01902/2017) and Grant PID2020-115121GB-I00 funded by MCIN/AEI/10.13039/501100011033 to A. Barreiro-IglesiasS

    Cost-efficiency assessment of Advanced Life Support (ALS) courses based on the comparison of advanced simulators with conventional manikins

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Simulation is an essential tool in modern medical education. The object of this study was to assess, in cost-effective measures, the introduction of new generation simulators in an adult life support (ALS) education program.</p> <p>Methods</p> <p>Two hundred fifty primary care physicians and nurses were admitted to ten ALS courses (25 students per course). Students were distributed at random in two groups (125 each). Group A candidates were trained and tested with standard ALS manikins and Group B ones with new generation emergency and life support integrated simulator systems.</p> <p>Results</p> <p>In group A, 98 (78%) candidates passed the course, compared with 110 (88%) in group B (p < 0.01). The total cost of conventional courses was €7689 per course and the cost of the advanced simulator courses was €29034 per course (p < 0.001). Cost per passed student was €392 in group A and €1320 in group B (p < 0.001).</p> <p>Conclusion</p> <p>Although ALS advanced simulator systems may slightly increase the rate of students who pass the course, the cost-effectiveness of ALS courses with standard manikins is clearly superior.</p

    Search for new phenomena in final states with an energetic jet and large missing transverse momentum in pp collisions at √ s = 8 TeV with the ATLAS detector

    Get PDF
    Results of a search for new phenomena in final states with an energetic jet and large missing transverse momentum are reported. The search uses 20.3 fb−1 of √ s = 8 TeV data collected in 2012 with the ATLAS detector at the LHC. Events are required to have at least one jet with pT > 120 GeV and no leptons. Nine signal regions are considered with increasing missing transverse momentum requirements between Emiss T > 150 GeV and Emiss T > 700 GeV. Good agreement is observed between the number of events in data and Standard Model expectations. The results are translated into exclusion limits on models with either large extra spatial dimensions, pair production of weakly interacting dark matter candidates, or production of very light gravitinos in a gauge-mediated supersymmetric model. In addition, limits on the production of an invisibly decaying Higgs-like boson leading to similar topologies in the final state are presente

    Preparation and Evaluation of Poly(Ethylene Glycol)–Poly(Lactide) Micelles as Nanocarriers for Oral Delivery of Cyclosporine A

    Get PDF
    A series of monomethoxy poly(ethylene glycol)–poly(lactide) (mPEG–PLA) diblock copolymers were designed according to polymer–drug compatibility and synthesized, and mPEG–PLA micelle was fabricated and used as a nanocarrier for solubilization and oral delivery of Cyclosporine A (CyA). CyA was efficiently encapsulated into the micelles with nanoscaled diameter ranged from 60 to 96 nm with a narrow size distribution. The favorable stabilities of CyA-loaded polymeric micelles were observed in simulated gastric and intestinal fluids. The in vitro drug release investigation demonstrated that drug release was retarded by polymeric micelles. The enhanced intestinal absorption of CyA-loaded polymeric micelles, which was comparable to the commercial formulation of CyA (Sandimmun Neoral®), was found. These suggested that polymeric micelles might be an effective nanocarrier for solubilization of poorly soluble CyA and further improving oral absorption of the drug

    Clinical experience with integrase inhibitors in HIV-2-infected individuals in Spain.

    Get PDF
    Background: HIV-2 is a neglected virus despite estimates of 1–2 million people being infected worldwide. The virus is naturally resistant to some antiretrovirals used to treat HIV-1 and therapeutic options are limited for patients with HIV-2. Methods: In this retrospective observational study, we analysed all HIV-2-infected individuals treated with inte- grase strand transfer inhibitors (INSTIs) recorded in the Spanish HIV-2 cohort. Demographics, treatment modal- ities, laboratory values, quantitative HIV-2 RNA and CD4 counts as well as drug resistance were analysed. Results: From a total of 354 HIV-2-infected patients recruited by the Spanish HIV-2 cohort as of December 2017, INSTIs had been given to 44, in 18 as first-line therapy and in 26 after failing other antiretroviral regimens. After a median follow-up of 13 months of INSTI-based therapy, undetectable viraemia for HIV-2 was achieved in 89% of treatment-naive and in 65.4% of treatment-experienced patients. In parallel, CD4 gains were 82 and 126cells/mm3, respectively. Treatment failure occurred in 15 patients, 2 being treatment-naive and 13 treatment-experienced. INSTI resistance changes were recognized in 12 patients: N155H (5), Q148H/R (3), Y143C/G (3) and R263K (1). Conclusions: Combinations based on INSTIs are effective and safe treatment options for HIV-2-infected individ- uals. However, resistance mutations to INSTIs are selected frequently in failing patients, reducing the already limited treatment options

    HTLV-1 infection in solid organ transplant donors and recipients in Spain

    Get PDF
    Background: HTLV-1 infection is a neglected disease, despite infecting 10–15 million people worldwide and severe illnesses develop in 10% of carriers lifelong. Acknowledging a greater risk for developing HTLV-1 associated illnesses due to immunosuppression, screening is being widely considered in the transplantation setting. Herein, we report the experience with universal HTLV testing of donors and recipients of solid organ transplants in a survey conducted in Spain. Methods: All hospitals belonging to the Spanish HTLV network were invited to participate in the study. Briefly, HTLV antibody screening was performed retrospectively in all specimens collected from solid organ donors and recipients attended since the year 2008. Results: A total of 5751 individuals were tested for HTLV antibodies at 8 sites. Donors represented 2312 (42.2%), of whom 17 (0.3%) were living kidney donors. The remaining 3439 (59.8%) were recipients. Spaniards represented nearly 80%. Overall, 9 individuals (0.16%) were initially reactive for HTLV antibodies. Six were donors and 3 were recipients. Using confirmatory tests, HTLV-1 could be confirmed in only two donors, one Spaniard and another from Colombia. Both kidneys of the Spaniard were inadvertently transplanted. Subacute myelopathy developed within 1 year in one recipient. The second recipient seroconverted for HTLV-1 but the kidney had to be removed soon due to rejection. Immunosuppression was stopped and 3 years later the patient remains in dialysis but otherwise asymptomatic. Conclusion: The rate of HTLV-1 is low but not negligible in donors/recipients of solid organ transplants in Spain. Universal HTLV screening should be recommended in all donor and recipients of solid organ transplantation in Spain. Evidence is overwhelming for very high virus transmission and increased risk along with the rapid development of subacute myelopath
    corecore