890 research outputs found
A stated preference model to value reductions in community severance
This paper presents the results of a stated preference survey to assess the value of reductions in community severance (the “barrier effect” of transport infrastructure on the mobility of pedestrians). In a first exercise, participants chose between crossing a road in a place without designated facilities or walking additional minutes to a place where the road is covered over. Half of the participants never chose to cross, regardless of the road design, traffic characteristics, and length of the detour. On average, the other half would only cross the road, if the detour was at least 7.5 minutes, or higher, if the road had extra traffic lanes, no central reservation, and high traffic density. In a second exercise, participants were asked if they would cross the road if they could save money by using a shop or a bus stop on the other side of the road, instead of one on their side of the road. 38% never chose to cross. The cost saving for which the other 62% would cross depends on the scenario, especially regarding traffic volume. On average, participants would only cross a road with high traffic volume if the saving was £2.8. Overall, the study suggests that many people are not willing to trade-off pedestrian safety with shorter walking times or cost savings. People who are willing to trade-off attach greater importance to some aspects (like traffic density) than others (like traffic speed)
Implementing health research through academic and clinical partnerships : a realistic evaluation of the Collaborations for Leadership in Applied Health Research and Care (CLAHRC)
Background: The English National Health Service has made a major investment in nine partnerships between
higher education institutions and local health services called Collaborations for Leadership in Applied Health
Research and Care (CLAHRC). They have been funded to increase capacity and capability to produce and
implement research through sustained interactions between academics and health services. CLAHRCs provide a
natural ‘test bed’ for exploring questions about research implementation within a partnership model of delivery.
This protocol describes an externally funded evaluation that focuses on implementation mechanisms and
processes within three CLAHRCs. It seeks to uncover what works, for whom, how, and in what circumstances.
Design and methods: This study is a longitudinal three-phase, multi-method realistic evaluation, which
deliberately aims to explore the boundaries around knowledge use in context. The evaluation funder wishes to see
it conducted for the process of learning, not for judging performance. The study is underpinned by a conceptual
framework that combines the Promoting Action on Research Implementation in Health Services and Knowledge to
Action frameworks to reflect the complexities of implementation. Three participating CLARHCS will provide indepth
comparative case studies of research implementation using multiple data collection methods including
interviews, observation, documents, and publicly available data to test and refine hypotheses over four rounds of
data collection. We will test the wider applicability of emerging findings with a wider community using an
interpretative forum.
Discussion: The idea that collaboration between academics and services might lead to more applicable health
research that is actually used in practice is theoretically and intuitively appealing; however the evidence for it is
limited. Our evaluation is designed to capture the processes and impacts of collaborative approaches for
implementing research, and therefore should contribute to the evidence base about an increasingly popular (e.g.,
Mode two, integrated knowledge transfer, interactive research), but poorly understood approach to knowledge
translation. Additionally we hope to develop approaches for evaluating implementation processes and impacts
particularly with respect to integrated stakeholder involvement
A CLINICAL STUDY OF INHALANT ANAESTHESIA IN DOGS
A clinical trial was undertaken using three different inhalant anaesthetic agents and one intravenous anaesthetic agent in dogs undergoing routine desexing surgery. Healthy adult dogs undergoing either ovariohysterectomy or castration were assessed as to their demeanour, with the more excitable dogs being placed in groups receiving premedication with acepromazine and morphine. All dogs were then randomly assigned an anaesthetic agent for induction of general anaesthesia. The agents were the inhalants halothane, isoflurane and sevoflurane, and the intravenous agent propofol. Inhalant inductions were undertaken using a tight fitting mask attached to a standard anaesthetic machine with a rebreathing circuit, with the maximum dose of inhalant available from a standard vaporiser. Propofol inductions were undertaken via intravenous catheter. Dogs induced with propofol were randomly assigned one of the three inhalant agents for maintenance. Those induced by inhalant agent were maintained using the same agent. The surgical procedure was undertaken in standard fashion, as was recovery from anaesthesia. All dogs received the non-steroidal anti-inflammatory agent meloxicam. Data collection was divided into three stages: induction, maintenance, and recovery from anaesthesia. Variables measured at induction of anaesthesia were time to intubation, number of intubation attempts, tolerance of mask, quality of induction and quality of transfer to the maintenance stage. Standard variables for monitoring of anaesthesia were recorded throughout the maintenance of anaesthesia. Variables measured at recovery were time to righting, time to standing and quality of recovery. The mean time to intubation when using the newer inhalant sevoflurane (196.2 ± 14.8sec, mean ± SE) was not significantly different to that for halothane (221.4 ± 14.0sec) or isoflurane (172.4 ± 15.0sec). Time to intubation with isoflurane was significantly faster than with halothane. Mean time to intubation with propofol (85.4 ± 7.7sec) was significantly faster than that for any of the three inhalants. Choice of inhalant had no effect on quality of induction. The use of premedication significantly improved the quality of induction. The use of propofol for induction likewise significantly improved the quality of induction. Standard cardiorespiratory variables measured during the maintenance phase of anaesthesia remained within normal clinical ranges for all three inhalants, and were therefore not further analysed. Choice of inhalant agent had no significant effect on the time to righting or standing in recovery. The use of propofol for induction had no effect on these variables. Animals placed in groups receiving premedication had significantly longer times to righting and standing. The oesophageal temperature at the end of the procedure had a significant effect on times to righting and standing, with lower temperatures contributing to slower recoveries. Independent of procedure time, male dogs had shorter times to righting than female dogs
Recommended from our members
A Search for Dark Higgs Bosons
Recent astrophysical and terrestrial experiments have motivated the proposal
of a dark sector with GeV-scale gauge boson force carriers and new Higgs
bosons. We present a search for a dark Higgs boson using 516 fb-1 of data
collected with the BABAR detector. We do not observe a significant signal and
we set 90% confidence level upper limits on the product of the Standard
Model-dark sector mixing angle and the dark sector coupling constant.Comment: 7 pages, 5 postscript figures, published version with improved plots
for b/w printin
Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV
The performance of muon reconstruction, identification, and triggering in CMS
has been studied using 40 inverse picobarns of data collected in pp collisions
at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection
criteria covering a wide range of physics analysis needs have been examined.
For all considered selections, the efficiency to reconstruct and identify a
muon with a transverse momentum pT larger than a few GeV is above 95% over the
whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4,
while the probability to misidentify a hadron as a muon is well below 1%. The
efficiency to trigger on single muons with pT above a few GeV is higher than
90% over the full eta range, and typically substantially better. The overall
momentum scale is measured to a precision of 0.2% with muons from Z decays. The
transverse momentum resolution varies from 1% to 6% depending on pseudorapidity
for muons with pT below 100 GeV and, using cosmic rays, it is shown to be
better than 10% in the central region up to pT = 1 TeV. Observed distributions
of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV
The performance of muon reconstruction, identification, and triggering in CMS
has been studied using 40 inverse picobarns of data collected in pp collisions
at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection
criteria covering a wide range of physics analysis needs have been examined.
For all considered selections, the efficiency to reconstruct and identify a
muon with a transverse momentum pT larger than a few GeV is above 95% over the
whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4,
while the probability to misidentify a hadron as a muon is well below 1%. The
efficiency to trigger on single muons with pT above a few GeV is higher than
90% over the full eta range, and typically substantially better. The overall
momentum scale is measured to a precision of 0.2% with muons from Z decays. The
transverse momentum resolution varies from 1% to 6% depending on pseudorapidity
for muons with pT below 100 GeV and, using cosmic rays, it is shown to be
better than 10% in the central region up to pT = 1 TeV. Observed distributions
of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
X-ray emission from the Sombrero galaxy: discrete sources
We present a study of discrete X-ray sources in and around the
bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival
Chandra observations with a total exposure of ~200 ks. With a detection limit
of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30
kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler
et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS
observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray
binaries (LMXBs). We quantify the differential luminosity functions (LFs) for
both the detected GC and field LMXBs, whose power-low indices (~1.1 for the
GC-LF and ~1.6 for field-LF) are consistent with previous studies for
elliptical galaxies. With precise sky positions of the GCs without a detected
X-ray source, we further quantify, through a fluctuation analysis, the GC LF at
fainter luminosities down to 1E35 erg/s. The derived index rules out a
faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent
findings in several elliptical galaxies and the bulge of M31. On the other
hand, the 2-6 keV unresolved emission places a tight constraint on the field
LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101
sources in the halo of Sombrero. The presence of these sources cannot be
interpreted as galactic LMXBs whose spatial distribution empirically follows
the starlight. Their number is also higher than the expected number of cosmic
AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray
surveys. We suggest that either the cosmic X-ray background is unusually high
in the direction of Sombrero, or a distinct population of X-ray sources is
present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres
Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV
The azimuthal anisotropy of charged particles in PbPb collisions at
nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS
detector at the LHC over an extended transverse momentum (pt) range up to
approximately 60 GeV. The data cover both the low-pt region associated with
hydrodynamic flow phenomena and the high-pt region where the anisotropies may
reflect the path-length dependence of parton energy loss in the created medium.
The anisotropy parameter (v2) of the particles is extracted by correlating
charged tracks with respect to the event-plane reconstructed by using the
energy deposited in forward-angle calorimeters. For the six bins of collision
centrality studied, spanning the range of 0-60% most-central events, the
observed v2 values are found to first increase with pt, reaching a maximum
around pt = 3 GeV, and then to gradually decrease to almost zero, with the
decline persisting up to at least pt = 40 GeV over the full centrality range
measured.Comment: Replaced with published version. Added journal reference and DO
Search for new physics with same-sign isolated dilepton events with jets and missing transverse energy
A search for new physics is performed in events with two same-sign isolated
leptons, hadronic jets, and missing transverse energy in the final state. The
analysis is based on a data sample corresponding to an integrated luminosity of
4.98 inverse femtobarns produced in pp collisions at a center-of-mass energy of
7 TeV collected by the CMS experiment at the LHC. This constitutes a factor of
140 increase in integrated luminosity over previously published results. The
observed yields agree with the standard model predictions and thus no evidence
for new physics is found. The observations are used to set upper limits on
possible new physics contributions and to constrain supersymmetric models. To
facilitate the interpretation of the data in a broader range of new physics
scenarios, information on the event selection, detector response, and
efficiencies is provided.Comment: Published in Physical Review Letter
- …