1,279 research outputs found

    Reducing the risk of non-sterility of aseptic handling in hospital pharmacies, part C:Applying risk assessment and risk control in practice

    Get PDF
    OBJECTIVES: To describe the application of the model described in part A and part B of this series of articles for risk assessment (RA) and risk control (RC) of non-sterility during aseptic handling. The model was applied in nine hospital pharmacies.METHODS: The starting point was an audit of each hospital pharmacy. The determined risk reduction and remaining risks were entered into a risk assessment model. The corresponding risk prioritisation numbers (RPNs) for each source of risk were calculated and these values were summed up to a cumulative RPN. Subsequently, all hospital pharmacies started an improvement programme, using the risk assessment as input. Results of aseptic process simulation (APS) and microbiological monitoring (MM) were also collected. The participants were informed about their progress of risk reduction and results of APS and MM during the study period. At the end of the study (about 4 years after the start), a final assessment was executed by using a checklist with risk reducing measures for each source of risk. Additional risk reduction and remaining risks were put in an RA and RC template and corresponding RPN values and a new cumulative RPN were determined.RESULTS: At the start of the study differences in cumulative RPN values were relatively small (from 630 to 825). At the end they were relatively great (from 230 to 725), which illustrates a different sense of urgency for reducing the risk of non-sterility. Of all the risk reducing measures, a yearly audit of all operators had the greatest impact on reducing the risk of non-sterility. Except for glove prints, there was no correlation between process improvement (lower cumulative RPN) and results of microbiological controls.CONCLUSION: A systematic and science-based reduction of the risks of non-sterility can be done by using a checklist with risk reducing measures and an RA &amp; RC template. Prospectively, the relevance of each risk reducing measure can be demonstrated by RPN calculations. Microbiological controls are an important part of the overall assurance of product quality. However, the results are less useful for assessing the risk of non-sterility.</p

    Reducing the risk of non-sterility of aseptic handling in hospital pharmacies, part A:Risk assessment

    Get PDF
    OBJECTIVES: To determine prospectively the sources of risk of non-sterility during aseptic handling and to quantify the risks of each of these sources. METHODS: A risk assessment (RA) of non-sterility according to Failure Mode and Effect Analysis was executed by a multidisciplinary team of (hospital) pharmacists and technicians, a consultant experienced in aseptic processing and an independent facilitator. The team determined the sources of risk of non-sterility, a 5 point scale for severity, occurrence and detection, and risk acceptance levels. Input about general applied risk reduction was collected by audits in 10 hospital pharmacies. The results of these audits were used for determining the remaining risks. The results, as well as scientific information and the experience of the team members, was used to determine scores for severity, occurrence and detection. RESULTS: Multiplying the scores for severity, occurrence and detection results in the risk prioritisation number (RPN) which is a relative value of the remaining risks of non-sterility for each source. Incorrect disinfection techniques of non-sterile materials and the chances of touching critical spots were estimated as the greatest risks. The risk of non-sterility via the airborne route was low. RPN values were helpful in prioritising measures for additional risk reduction (this will be described in an accompanying article). CONCLUSION: The RA, described here, was a systematic survey related to all sources of risk of non-sterility during aseptic handling. The determined RPN values were helpful in prioritising measures for additional risk reduction

    Improving the aseptic transfer procedures in hospital pharmacies. Part B:evaluation of disinfection methods for materials with a non-sterile surface

    Get PDF
    Objectives To improve the disinfection methods for materials with a non-sterile surface to be used in aseptic handling. Methods The surface bioburden on ampoules (A) and injection vials (IV) is determined by contact plates and total immersion. The occurrence of spore-forming bacteria is determined by strain colouring and matrix-assisted laser desorption ionisation-time of flight mass spectrometry. The disinfection procedures of non-sterile materials in 10 hospital pharmacies are judged by observing. Results After wiping according to local disinfection methods, the mean surface bioburden determined by contact plates in 10 hospital pharmacies is 0.36 (plastic A), 0.50 (glass A) and 0.29 colony-forming unit (cfu) (IV). The observers found great differences in accuracy of wiping and degree of wetting the sterile gauzes. After improved wiping with commercially available alcohol impregnated sterile wipes and a two-towel technique (one-step TT disinfection), the mean surface bioburden determined by contact plates is 0.03 (plastic A), 0.2 (glass A) and 0.13 cfu (IV). Further improvement can be reached by submerging A and IV in ethanol 70% followed by improved wiping (two-step TT disinfection), but still micro-organisms will remain (mean surface bioburden determined by total immersion is 0 (plastic A) and 0.3 cfu (IV); glass A not determined). Two-step TT disinfection is more labour intensive. Spilling of alcohol is another disadvantage. However, we presume one-step TT disinfection is effective enough in daily practice. Routine surface bioburden determinations have to prove this. The effectiveness of the combination of spray and wipe is not examined because we observed a quick disappearance of alcohols from vertical as well as horizontal surfaces, which shortens the contact time to far below the advised 2 min. Spore-forming bacteria disappear as quickly as other micro-organisms during disinfection by alcohols. Conclusion Local disinfection procedures can be improved. Complete removal of micro-organisms from materials with a non-sterile surface, even after two-step TT disinfection, is impossible. Routine surface bioburden determinations have to prove if one-step TT disinfection is effective enough

    Prime Focus Spectrograph (PFS) for the Subaru Telescope: Overview, recent progress, and future perspectives

    Full text link
    PFS (Prime Focus Spectrograph), a next generation facility instrument on the 8.2-meter Subaru Telescope, is a very wide-field, massively multiplexed, optical and near-infrared spectrograph. Exploiting the Subaru prime focus, 2394 reconfigurable fibers will be distributed over the 1.3 deg field of view. The spectrograph has been designed with 3 arms of blue, red, and near-infrared cameras to simultaneously observe spectra from 380nm to 1260nm in one exposure at a resolution of ~1.6-2.7A. An international collaboration is developing this instrument under the initiative of Kavli IPMU. The project is now going into the construction phase aiming at undertaking system integration in 2017-2018 and subsequently carrying out engineering operations in 2018-2019. This article gives an overview of the instrument, current project status and future paths forward.Comment: 17 pages, 10 figures. Proceeding of SPIE Astronomical Telescopes and Instrumentation 201

    The COMPASS Experiment at CERN

    Get PDF
    The COMPASS experiment makes use of the CERN SPS high-intensitymuon and hadron beams for the investigation of the nucleon spin structure and the spectroscopy of hadrons. One or more outgoing particles are detected in coincidence with the incoming muon or hadron. A large polarized target inside a superconducting solenoid is used for the measurements with the muon beam. Outgoing particles are detected by a two-stage, large angle and large momentum range spectrometer. The setup is built using several types of tracking detectors, according to the expected incident rate, required space resolution and the solid angle to be covered. Particle identification is achieved using a RICH counter and both hadron and electromagnetic calorimeters. The setup has been successfully operated from 2002 onwards using a muon beam. Data with a hadron beam were also collected in 2004. This article describes the main features and performances of the spectrometer in 2004; a short summary of the 2006 upgrade is also given.Comment: 84 papes, 74 figure

    Exploring the Trypanosoma brucei Hsp83 Potential as a Target for Structure Guided Drug Design

    Get PDF
    Human African trypanosomiasis is a neglected parasitic disease that is fatal if untreated. The current drugs available to eliminate the causative agent Trypanosoma brucei have multiple liabilities, including toxicity, increasing problems due to treatment failure and limited efficacy. There are two approaches to discover novel antimicrobial drugs--whole-cell screening and target-based discovery. In the latter case, there is a need to identify and validate novel drug targets in Trypanosoma parasites. The heat shock proteins (Hsp), while best known as cancer targets with a number of drug candidates in clinical development, are a family of emerging targets for infectious diseases. In this paper, we report the exploration of T. brucei Hsp83--a homolog of human Hsp90--as a drug target using multiple biophysical and biochemical techniques. Our approach included the characterization of the chemical sensitivity of the parasitic chaperone against a library of known Hsp90 inhibitors by means of differential scanning fluorimetry (DSF). Several compounds identified by this screening procedure were further studied using isothermal titration calorimetry (ITC) and X-ray crystallography, as well as tested in parasite growth inhibitions assays. These experiments led us to the identification of a benzamide derivative compound capable of interacting with TbHsp83 more strongly than with its human homologs and structural rationalization of this selectivity. The results highlight the opportunities created by subtle structural differences to develop new series of compounds to selectively target the Trypanosoma brucei chaperone and effectively kill the sleeping sickness parasite

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    A new measurement of the Collins and Sivers asymmetries on a transversely polarised deuteron target

    Get PDF
    New high precision measurements of the Collins and Sivers asymmetries of charged hadrons produced in deep-inelastic scattering of muons on a transversely polarised 6LiD target are presented. The data were taken in 2003 and 2004 with the COMPASS spectrometer using the muon beam of the CERN SPS at 160 GeV/c. Both the Collins and Sivers asymmetries turn out to be compatible with zero, within the present statistical errors, which are more than a factor of 2 smaller than those of the published COMPASS results from the 2002 data. The final results from the 2002, 2003 and 2004 runs are compared with naive expectations and with existing model calculations.Comment: 40 pages, 28 figure

    Performance and Operation of the CMS Electromagnetic Calorimeter

    Get PDF
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented

    Calibration of the CMS Drift Tube Chambers and Measurement of the Drift Velocity with Cosmic Rays

    Get PDF
    Peer reviewe
    corecore