286 research outputs found

    Quetiapine Poisoning and Factors Influencing Severity

    Get PDF
    PURPOSE/BACKGROUND: Quetiapine is a relatively new atypical antipsychotic with fewer adverse effects. It is increasingly prescribed to patients. The purpose of this study was to describe the cases of poisoning observed at the western France Poison Control Centre and identify potential risk factors that increase the severity of the cases. METHODS: This was a retrospective study of self-poisoning with quetiapine as reported by the western France Poison Control Centre between 2007 and 2017. RESULTS: There were 372 cases of quetiapine poisoning. Circumstances are known in 367 of 372 cases. There were 75 cases of null severity (grade 0), 133 cases of mild severity (grade 1), 85 cases of moderate severity (grade 2), and 79 cases of high severity (grade 3). Five deaths were listed in this series. The most commonly observed symptoms were neurological and cardiovascular in nature (drowsiness, coma, tachycardia, hypotension). Of these cases, 79.8% included voluntary ingestions. Among 302 cases with coagents, the most common coagents were benzodiazepines (56%), other psychotropic drugs (41%), and antidepressants (37%). An evaluated ingested dose 1500 mg or greater and 2 or more coagents increase the risk of severe poisoning. In particular, concomitant ingestion of benzodiazepines and antidepressants with quetiapine was associated with high severity (odds ratio, 2.478 [confidence interval, 1.3-4.723]; odds ratio, 1.820 [confidence interval, 1.010-3.316]). CONCLUSIONS: Quetiapine may lead to severe poisoning for which there is currently no specific treatment. Patients and practitioners should be aware of this when quetiapine is prescribed, particularly when used in combination with other medications, and in order to deal with cases of poisoning

    Determinants of Doppler-based renal resistive index in patients with septic shock: impact of hemodynamic parameters, acute kidney injury and predisposing factors

    Get PDF
    BACKGROUND: Increased renal resistive index (RI) measured by Doppler ultrasonography has been shown to be associated with acute kidney injury (AKI) in septic patients. However, its clinical use is limited by poor sensitivity and specificity which may be explained by its numerous determinants [in particular mean arterial pressure (MAP)]. We measured, in patients with septic shock, RI at different MAP levels over a short period of time on the admission day to ICU (D1) and every 3 days until day 10 (D10) to define the determinants of RI and study specifically the relationship between RI and MAP. RESULTS: Consecutive patients with septic shock without preexisting chronic renal dysfunction were included in this prospective cohort study in two ICUs. Sixty-five patients were included in the study. Thirty-three (50.8%) and 15 (23.1%) patients had a history of chronic hypertension or diabetes, respectively. At D3, 35 patients presented AKI with AKIN 2 or 3 criteria (severe AKI, AKIN2-3 group) and 30 presented no AKIN or AKIN 1 criteria (AKIN0-1 group). As previously described, RI at D1 was higher in the AKIN2-3 group than in the AKIN0-1 group (0.73 interquartile range [0.67; 0.78] vs. 0.67 [0.59; 0.72], p = 0.001). A linear mixed model for predicting RI from D1 to D10 showed that an increase in pulse pressure, presence of severe AKI and additional day of ICU hospitalization were associated with an increase in RI. An increase in MAP and recovery from severe AKI were associated with a decrease in RI. In the presence of chronic hypertension or diabetes, an increase in MAP resulted in a lower decrease in RI, than in the absence of such factors. Presence of AKI at D3 did not impact the relationship between MAP and RI. CONCLUSIONS: Severe AKI was associated with a reversible increase in RI without significant interaction with the relationship between MAP and RI. Conversely, the presence of chronic hypertension and/or diabetes interacted with this relationship

    Quantum Langevin theory of excess noise

    Full text link
    In an earlier work [P. J. Bardroff and S. Stenholm], we have derived a fully quantum mechanical description of excess noise in strongly damped lasers. This theory is used here to derive the corresponding quantum Langevin equations. Taking the semi-classical limit of these we are able to regain the starting point of Siegman's treatment of excess noise [Phys. Rev. A 39, 1253 (1989)]. Our results essentially constitute a quantum derivation of his theory and allow some generalizations.Comment: 9 pages, 0 figures, revte

    The human OPA1delTTAG mutation induces premature age-related systemic neurodegeneration in mouse

    Get PDF
    Dominant optic atrophy is a rare inherited optic nerve degeneration caused by mutations in the mitochondrial fusion gene OPA1. Recently, the clinical spectrum of dominant optic atrophy has been extended to frequent syndromic forms, exhibiting various degrees of neurological and muscle impairments frequently found in mitochondrial diseases. Although characterized by a specific loss of retinal ganglion cells, the pathophysiology of dominant optic atrophy is still poorly understood. We generated an Opa1 mouse model carrying the recurrent Opa1(delTTAG) mutation, which is found in 30% of all patients with dominant optic atrophy. We show that this mouse displays a multi-systemic poly-degenerative phenotype, with a presentation associating signs of visual failure, deafness, encephalomyopathy, peripheral neuropathy, ataxia and cardiomyopathy. Moreover, we found premature age-related axonal and myelin degenerations, increased autophagy and mitophagy and mitochondrial supercomplex instability preceding degeneration and cell death. Thus, these results support the concept that Opa1 protects against neuronal degeneration and opens new perspectives for the exploration and the treatment of mitochondrial diseases

    Intercalibration of the barrel electromagnetic calorimeter of the CMS experiment at start-up

    Get PDF
    Calibration of the relative response of the individual channels of the barrel electromagnetic calorimeter of the CMS detector was accomplished, before installation, with cosmic ray muons and test beams. One fourth of the calorimeter was exposed to a beam of high energy electrons and the relative calibration of the channels, the intercalibration, was found to be reproducible to a precision of about 0.3%. Additionally, data were collected with cosmic rays for the entire ECAL barrel during the commissioning phase. By comparing the intercalibration constants obtained with the electron beam data with those from the cosmic ray data, it is demonstrated that the latter provide an intercalibration precision of 1.5% over most of the barrel ECAL. The best intercalibration precision is expected to come from the analysis of events collected in situ during the LHC operation. Using data collected with both electrons and pion beams, several aspects of the intercalibration procedures based on electrons or neutral pions were investigated

    Flow of foam through a convergent channel

    No full text
    International audienceWe study experimentally the flow of a foam confined as a bubble monolayer between two plates through a convergent channel. We quantify the velocity, the distribution and orientation of plastic events, and the elastic stress, using image analysis. We use two different soap solutions: a sodium dodecyl sulfate (SDS) solution, with a negligible wall friction between the bubbles and the confining plates, and a mixture containing a fatty acid, giving a large wall friction. We show that for SDS solutions, the velocity profile obeys a self-similar form which results from the superposition of plastic events, and the elastic deformation is uniform. For the other solution, the velocity field differs and the elastic deformation increases towards the exit of the channel. We discuss and quantify the role of wall friction on the velocity profile, the elastic deformation, and the rate of plastic events

    Limits on the production of scalar leptoquarks from Z (0) decays at LEP

    Get PDF
    A search has been made for pairs and for single production of scalar leptoquarks of the first and second generations using a data sample of 392000 Z0 decays from the DELPHI detector at LEP 1. No signal was found and limits on the leptoquark mass, production cross section and branching ratio were set. A mass limit at 95% confidence level of 45.5 GeV/c2 was obtained for leptoquark pair production. The search for the production of a single leptoquark probed the mass region above this limit and its results exclude first and second generation leptoquarks D0 with masses below 65 GeV/c2 and 73 GeV/c2 respectively, at 95% confidence level, assuming that the D0lq Yukawa coupling alpha(lambda) is equal to the electromagnetic one. An upper limit is also given on the coupling alpha(lambda) as a function of the leptoquark mass m(D0)

    Searches for invisible decays of the Higgs boson in pp collisions at root S=7, 8, and 13 TeV

    Get PDF
    Peer reviewe

    Search for leptophobic Z ' bosons decaying into four-lepton final states in proton-proton collisions at root s=8 TeV

    Get PDF
    Peer reviewe
    corecore