171 research outputs found

    In situ thrombosis in pulmonary arterial aneurysms due to Behçet’s disease and efficacy of ımmunosuppressive therapy

    Get PDF
    BehçetDisease (BD) is a systemic vasculitis characterized by recurrent oral and genital ulcers and uveitis, arthritis, and involvement of the gastrointestinal tract, central nervous system and blood vessels. The aneurysms of the pulmonary arteries, with or without thrombosis, are typical manifestation of BD. We report a case with BD, pulmonary arterial aneurysms(PAA) and in situ thrombosis. We aimed to show the effectiveness of immunosuppressive treatment on in situ thrombosis in a case with PAA and BD

    Deep learning for diagnosis of malign pleural effusion on computed tomography images

    Get PDF
    Background: The pleura is a serous membrane that surrounds the lungs. The visceral surface secretes fluid into the serous cavity and the parietal surface ensures a regular absorption of this fluid. If this balance is disturbed, fluid accumulation occurs in the pleural space called “Pleural Effusion”. Today, accurate diagnosis of pleural diseases is becoming more critical, as advances in treatment protocols have contributed positively to prognosis. Our aim is to perform computer-aided numerical analysis of Computed Tomography (CT) images from patients showing pleural effusion images on CT and to examine the prediction of malignant/benign distinction using deep learning by comparing with the cytology results. Methods: The authors classified 408 CT images from 64 patients whose etiology of pleural effusion was investigated using the deep learning method. 378 of the images were used for the training of the system; 15 malignant and 15 benign CT images, which were not included in the training group, were used as the test. Results: Among the 30 test images evaluated in the system; 14 of 15 malignant patients and 13 of 15 benign patients were estimated with correct diagnosis (PPD: 93.3%, NPD: 86.67%, Sensitivity: 87.5%, Specificity: 92.86%). Conclusion: Advances in computer-aided diagnostic analysis of CT images and obtaining a pre-diagnosis of pleural fluid may reduce the need for interventional procedures by guiding physicians about which patients may have malignancies. Thus, it is cost and time-saving in patient management, allowing earlier diagnosis and treatment.

    Irradiation for mold and mycotoxin control : a review

    Get PDF
    The mycotoxin issue requires constant vigilance from economic, regulatory, and scientific agents to minimize its toxicological effects on human and on animals. The implementation of good practices to avoid fungal growth and mycotoxin production on agricultural commodities is essential to achieve most restrictive safety standards; however, the contribution of novel technologies that may act on post-harvesting and post-storage situations may be equally important. Several methodologies, more or less technologically advanced, may be used for this purpose. In this work, we review the role, contribution, and impact of irradiation technology to control the presence of fungi and mycotoxins in food and in feed. The effect of this technology on the viability of mold spores and on the elimination of mycotoxins is reviewed. A critical evaluation of the advantages and disadvantages of irradiation in this context is presented.Thalita Calado and Luis Abrunhosa received support through grants SFRH/BD/79364/2011 and SFRH/BPD/43922/2008, respectively, from the Fundacao para a Ciencia e Tecnologia - FCT, Portugal. The authors also thank the FCT Strategic Project PEst-OE/EQB/LA0023/2013 and the project "BioInd - Biotechnology and Bioengineering for Improved Industrial and Agro-Food processes, REF. NORTE-07-0124-FEDER-000028," which is cofunded by the Programa Operacional Regional do Norte (ON. 2 - O Novo Norte), QREN, FEDER

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Performance and Operation of the CMS Electromagnetic Calorimeter

    Get PDF
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented

    Calibration of the CMS Drift Tube Chambers and Measurement of the Drift Velocity with Cosmic Rays

    Get PDF
    Peer reviewe

    CMS Data Processing Workflows during an Extended Cosmic Ray Run

    Get PDF
    Peer reviewe

    CMS physics technical design report : Addendum on high density QCD with heavy ions

    Get PDF
    Peer reviewe

    Aligning the CMS Muon Chambers with the Muon Alignment System during an Extended Cosmic Ray Run

    Get PDF
    Peer reviewe

    Alignment of the CMS muon system with cosmic-ray and beam-halo muons

    Get PDF
    This is the Pre-print version of the Article. The official published version of the Paper can be accessed from the link below - Copyright @ 2010 IOPThe CMS muon system has been aligned using cosmic-ray muons collected in 2008 and beam-halo muons from the 2008 LHC circulating beam tests. After alignment, the resolution of the most sensitive coordinate is 80 microns for the relative positions of superlayers in the same barrel chamber and 270 microns for the relative positions of endcap chambers in the same ring structure. The resolution on the position of the central barrel chambers relative to the tracker is comprised between two extreme estimates, 200 and 700 microns, provided by two complementary studies. With minor modifications, the alignment procedures can be applied using muons from LHC collisions, leading to additional significant improvements.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR(Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)
    • …
    corecore