60 research outputs found

    Preanalytical issues related to routine and diagnostic glucose tests: Results from a survey in Spain

    Get PDF
    Introduction: Diabetes mellitus (DM) is one of the most prevalent diseases worldwide. The objective of this study was to find out under what preanalytical conditions routine and diagnostic glucose tests are performed across Spanish laboratories; and also what criteria are used for DM diagnosis. Materials and methods: An online survey was performed by the Commission on Quality Assurance in the Extra-Analytical Phase of the Spanish Society of Laboratory Medicine (SEQC-ML). Access to the questionnaire was available on the home page of the SEQC-ML website during the period April-July 2018. Data analysis was conducted with the IBM SPSS© Statistics (version 20.0) program. Results: A total of 96 valid surveys were obtained. Most laboratories were in public ownership, serving hospital and primary care patients, with high and medium workloads, and a predominance of mixed routine-urgent glucose testing. Serum tubes were the most used for routine glucose analysis (92%) and DM diagnosis (54%); followed by lithium-heparin plasma tubes (62%), intended primarily for urgent glucose testing; point-of care testing devices were used by 37%; and plasma tubes with a glycolysis inhibitor, mainly sodium fluoride, by 19%. Laboratories used the cut-off values and criteria recognized worldwide for DM diagnosis in adults and glucose-impaired tolerance, but diverged in terms of fasting plasma glucose and gestational DM criteria. Conclusion: Preanalytical processing of routine and DM diagnostic glucose testing in Spain does not allow a significant, non-quantified influence of glycolysis on the results to be ruled out. Possible adverse consequences include a delay in diagnosis and possible under-treatment

    Preanalytical issues related to routine and diagnostic glucose tests: Results from a survey in Spain

    Get PDF
    Introduction: Diabetes mellitus (DM) is one of the most prevalent diseases worldwide. The objective of this study was to find out under what preanalytical conditions routine and diagnostic glucose tests are performed across Spanish laboratories; and also what criteria are used for DM diagnosis. Materials and methods: An online survey was performed by the Commission on Quality Assurance in the Extra-Analytical Phase of the Spanish Society of Laboratory Medicine (SEQC-ML). Access to the questionnaire was available on the home page of the SEQC-ML website during the period April-July 2018. Data analysis was conducted with the IBM SPSS© Statistics (version 20.0) program. Results: A total of 96 valid surveys were obtained. Most laboratories were in public ownership, serving hospital and primary care patients, with high and medium workloads, and a predominance of mixed routine-urgent glucose testing. Serum tubes were the most used for routine glucose analysis (92%) and DM diagnosis (54%); followed by lithium-heparin plasma tubes (62%), intended primarily for urgent glucose testing; point-ofcare testing devices were used by 37%; and plasma tubes with a glycolysis inhibitor, mainly sodium fluoride, by 19%. Laboratories used the cut-off values and criteria recognized worldwide for DM diagnosis in adults and glucose-impaired tolerance, but diverged in terms of fasting plasma glucose and gestational DM criteria. Conclusion: Preanalytical processing of routine and DM diagnostic glucose testing in Spain does not allow a significant, non-quantified influence of glycolysis on the results to be ruled out. Possible adverse consequences include a delay in diagnosis and possible under-treatmen

    Predictive Power of the "Trigger Tool" for the detection of adverse events in general surgery: a multicenter observational validation study

    Get PDF
    Background In spite of the global implementation of standardized surgical safety checklists and evidence-based practices, general surgery remains associated with a high residual risk of preventable perioperative complications and adverse events. This study was designed to validate the hypothesis that a new “Trigger Tool” represents a sensitive predictor of adverse events in general surgery. Methods An observational multicenter validation study was performed among 31 hospitals in Spain. The previously described “Trigger Tool” based on 40 specific triggers was applied to validate the predictive power of predicting adverse events in the perioperative care of surgical patients. A prediction model was used by means of a binary logistic regression analysis. Results The prevalence of adverse events among a total of 1,132 surgical cases included in this study was 31.53%. The “Trigger Tool” had a sensitivity and specificity of 86.27% and 79.55% respectively for predicting these adverse events. A total of 12 selected triggers of overall 40 triggers were identified for optimizing the predictive power of the “Trigger Tool”. Conclusions The “Trigger Tool” has a high predictive capacity for predicting adverse events in surgical procedures. We recommend a revision of the original 40 triggers to 12 selected triggers to optimize the predictive power of this tool, which will have to be validated in future studies

    Educar para los nuevos Medios. Claves para el desarrollo de la competencia mediática en el entorno digital

    Get PDF
    Educar es una de las labores más complejas, intensas y, a la vez, más maravillosas que puede acometer una persona. Ser docente es una tarea ilusionante. En un mundo en el que la información es cada vez más importante por la rapidez con que se produce y consume, la variedad de recursos con que se difunde constituye un reto en el papel de los educadores y educadoras. La educación para la comunicación, a través de los nuevos medios, requiere de habilidades y estrategias específicas e implica prácticas innovadoras. Este texto ofrece claves para desarrollar la competencia mediática necesaria para entender, usar y comunicar en el entorno digital. Desde el concepto de competencia mediática y la escuela prosumidora se muestran experiencias y planteamientos en distintos niveles educativos y contextos curriculares que ofrecen pistas para educar a la ciudadanía. Esta alfabetización aúna la perspectiva de la experiencia de docente receptor y consumidor, atendiendo a la recepción crítica de la información, la selección y administración de la misma, el reconocimiento de valores e ideologías y la gestión emocional, junto a la elaboración y creación de contenidos

    Trends in the epidemiology of catheter-related bloodstream infections; towards a paradigm shift, Spain, 2007 to 2019

    Get PDF
    Altres ajuts: Departament de Salut. Generalitat de Catalunya ("Pla estratègic de recerca i innovació en salut (PERIS) 2019-2021"); Ministerio de Asuntos Económicos y Transformación Digital; Red Española de Investigación en Patología Infecciosa (REIPI).Background: Catheter-related bloodstream infections (CRBSI) are frequent healthcare-associated infections and an important cause of death. Aim: To analyse changes in CRBSI epidemiology observed by the Infection Control Catalan Programme (VINCat). Methods: A cohort study including all hospital-acquired CRBSI episodes diagnosed at 55 hospitals (2007-2019) in Catalonia, Spain, was prospectively conducted. CRBSI incidence rates were adjusted per 1,000patientdays. To assess the CRBSI rate trend per year, negative binomial models were used, with the number of events as the dependent variable, and the year as the main independent variable. From each model, the annual rate of CRBSI diagnosed per 1,000patientdays and the incidence rate ratio (IRR) with its 95% confidence intervals (CI) were reported. Results: During the study, 9,290 CRBSI episodes were diagnosed (mean annual incidence rate:0.20episodes/1,000patientdays). Patients' median age was 64.1years; 36.6% (3,403/9,290) were female. In total, 73.7% (n=6,845) of CRBSI occurred in non-intensive care unit (ICU) wards, 62.7% (n=5,822) were related to central venous catheter (CVC), 24.1% (n=2,236) to peripheral venous catheters (PVC) and 13.3% (n=1,232) to peripherally-inserted central venous catheters (PICVC). Incidence rate fell over the study period (IRR:0.94;95%CI:0.93-0.96), especially in the ICU (IRR:0.88;95%CI:0.87-0.89). As a whole, while episodes of CVC CRBSI fell significantly (IRR:0.88;95%CI:0.87-0.91), peripherally-inserted catheter CRBSI (PVC and PICVC) rose, especially in medical wards (IRR PICVC:1.08;95%CI:1.05-1.11; IRR PVC: 1.03; 95% 1.00-1.05). Conclusions: Over the study, CRBSIs associated with CVC and diagnosed in ICUs decreased while episodes in conventional wards involving peripherally-inserted catheters increased. Hospitals should implement preventive measures in conventional wards

    Search for dark matter produced in association with bottom or top quarks in √s = 13 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for weakly interacting massive particle dark matter produced in association with bottom or top quarks is presented. Final states containing third-generation quarks and miss- ing transverse momentum are considered. The analysis uses 36.1 fb−1 of proton–proton collision data recorded by the ATLAS experiment at √s = 13 TeV in 2015 and 2016. No significant excess of events above the estimated backgrounds is observed. The results are in- terpreted in the framework of simplified models of spin-0 dark-matter mediators. For colour- neutral spin-0 mediators produced in association with top quarks and decaying into a pair of dark-matter particles, mediator masses below 50 GeV are excluded assuming a dark-matter candidate mass of 1 GeV and unitary couplings. For scalar and pseudoscalar mediators produced in association with bottom quarks, the search sets limits on the production cross- section of 300 times the predicted rate for mediators with masses between 10 and 50 GeV and assuming a dark-matter mass of 1 GeV and unitary coupling. Constraints on colour- charged scalar simplified models are also presented. Assuming a dark-matter particle mass of 35 GeV, mediator particles with mass below 1.1 TeV are excluded for couplings yielding a dark-matter relic density consistent with measurements
    corecore