1,800 research outputs found

    Increased incidence of postoperative infections during prophylaxis with cephalothin compared to doxycycline in intestinal surgery

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The antibiotics used for prophylaxis during surgery may influence the rate of surgical site infections. Tetracyclines are attractive having a long half-life and few side effects when used in a single dose regimen. We studied the rate of surgical site infections during changing regimens of antibiotic prophylaxis in medium and major size surgery.</p> <p>Methods</p> <p>Prospective registration of surgical site infection following intestinal resections and hysterectomies was performed. Possible confounding procedure and patient related factors were registered. The study included 1541 procedures and 1489 controls. The registration included time periods when the regimen was changed from doxycycline to cephalothin and back again.</p> <p>Results</p> <p>The SSI in the colorectal department increased from 19% to 30% (p = 0.002) when doxycycline was substituted with cephalothin and decreased to 17% when we changed back to doxycycline (p = 0.005). In the gynaecology department the surgical site infection rate did not increase significantly. Subgroup analysis showed major changes in infections in rectal resections from 20% to 35% (p = 0.02) and back to 12% (p = 0.003).</p> <p>Conclusion</p> <p>Doxycycline combined with metronidazole, is an attractive candidate for antibiotic prophylaxis in medium and major size intestinal surgery.</p

    Cefuroxime Pharmacokinetics in Pediatric Cardiovascular Surgery Patients Undergoing Cardiopulmonary Bypass

    Get PDF
    Objectives The objective of this study was to determine the pharmacokinetics of cefuroxime in children undergoing cardiopulmonary bypass (CPB) for cardiovascular surgery. Design A prospective study. Setting A tertiary pediatric teaching hospital. Participants Infants and children undergoing CPB were enrolled in the study. Intervention An initial dose (mean, 24.2 ± 1.6 mg/kg) of cefuroxime was administered before surgical incision, and a second dose (mean, 14.4 ± 7.9 mg/kg) was administered in the CPB prime solution. Serial blood samples were obtained before, during, and after the CPB process. Samples were shipped on dry ice to the analytic laboratory and concentrations determined by a validated high-performance liquid chromatography method. A 2-compartment pharmacokinetic model was fitted to the data using maximum a priori–Bayesian estimation, with weight as a covariate. Monte Carlo simulations of a single-dose (25 mg/kg pre-CPB) approach and a 2-dose (25 mg/kg pre- and 12.5-mg/kg prime solution dose) approach were performed. Measurements and Main Results Fifteen subjects (9 males/6 females) were enrolled in the study, with median (range) age and weight of 11 (3-34) months and 9.5 (4.5-15.4) kg, respectively. The median (range) duration of CPB was 136 (71-243) minutes. Median and range cefuroxime pharmacokinetic parameters were as follows: maximum concentration (Cmax) dose, 1: 328 (150-512) μg/mL; systemic clearance, 0.050 (0.041-0.058) L/h/kg; steady-state volume of distribution, 0.213 (0.081-0.423) L/kg; volume of distribution in the central compartment, 0.081 (0.046-0.162) L/kg; and elimination half-life, 3.76 (1.03-6.81) hours. The median 8-hour post–dose-simulated cefuroxime concentrations were 26.5 and 16.0 mg/L for the 2-dose and single-dose regimens, respectively. Conclusion Manufacturers recommend that pediatric doses of cefuroxime (25-50 mg/kg) can be used in infants and children undergoing CPB to maintain adequate serum concentrations for surgical-site infection prophylaxis. A second intraoperative dose, administered through the CPB circuit, provides no additional prophylactic advantage

    Shadowing in Inelastic Scattering of Muons on Carbon, Calcium and Lead at Low XBj

    Full text link
    Nuclear shadowing is observed in the per-nucleon cross-sections of positive muons on carbon, calcium and lead as compared to deuterium. The data were taken by Fermilab experiment E665 using inelastically scattered muons of mean incident momentum 470 GeV/c. Cross-section ratios are presented in the kinematic region 0.0001 < XBj <0.56 and 0.1 < Q**2 < 80 GeVc. The data are consistent with no significant nu or Q**2 dependence at fixed XBj. As XBj decreases, the size of the shadowing effect, as well as its A dependence, are found to approach the corresponding measurements in photoproduction.Comment: 22 pages, incl. 6 figures, to be published in Z. Phys.

    Medical and Financial Risks Associated with Surgery in the Elderly Obese

    Get PDF
    OBJECTIVE: To study the medical and financial outcomes associated with surgery in elderly obese patients and to ask if obesity itself influences outcomes above and beyond the effects from comorbidities that are known to be associated with obesity. BACKGROUND: Obesity is a surgical risk factor not present in Medicare\u27s risk adjustment or payment algorithms, as BMI is not collected in administrative claims. METHODS: A total of 2045 severely or morbidly obese patients (BMI ≥ 35 kg/m, aged between 65 and 80 years) selected from 15,914 elderly patients in 47 hospitals undergoing hip and knee surgery, colectomy, and thoracotomy were matched to 2 sets of 2045 nonobese patients (BMI = 20-30 kg/m). A limited match controlled for age, sex, race, procedure, and hospital. A complete match also controlled for 30 additional factors such as diabetes and admission clinical data from chart abstraction. RESULTS: Mean BMI in the obese patients was 40 kg/m compared with 26 kg/m in the nonobese. In the complete match, obese patients displayed increased odds of wound infection: OR (odds ratio) = 1.64 (95% CI: 1.21, 2.21); renal dysfunction: OR = 2.05 (1.39, 3.05); urinary tract infection: OR = 1.55 (1.24, 1.94); hypotension: OR = 1.38 (1.07, 1.80); respiratory events: OR = 1.44 (1.19, 1.75); 30-day readmission: OR = 1.38 (1.08, 1.77); and a 12% longer length of stay (8%, 17%). Provider costs were 10% (7%, 12%) greater in obese than in nonobese patients, whereas Medicare payments increased only 3% (2%, 5%). Findings were similar in the limited match. CONCLUSIONS: Obesity increases the risks and costs of surgery. Better approaches are needed to reduce these risks. Furthermore, to avoid incentives to underserve this population, Medicare should consider incorporating incremental costs of caring for obese patients into payment policy and include obesity in severity adjustment models

    Lambda and Antilambda polarization from deep inelastic muon scattering

    Full text link
    We report results of the first measurements of Lambda and Antilambda polarization produced in deep inelastic polarized muon scattering on the nucleon. The results are consistent with an expected trend towards positive polarization with increasing x_F. The polarizations of Lambda and Antilambda appear to have opposite signs. A large negative polarization for Lambda at low positive x_F is observed and is not explained by existing models.A possible interpretation is presented.Comment: 9 pages, 2 figure

    Measurement of the cross-section and charge asymmetry of WW bosons produced in proton-proton collisions at s=8\sqrt{s}=8 TeV with the ATLAS detector

    Get PDF
    This paper presents measurements of the W+μ+νW^+ \rightarrow \mu^+\nu and WμνW^- \rightarrow \mu^-\nu cross-sections and the associated charge asymmetry as a function of the absolute pseudorapidity of the decay muon. The data were collected in proton--proton collisions at a centre-of-mass energy of 8 TeV with the ATLAS experiment at the LHC and correspond to a total integrated luminosity of 20.2~\mbox{fb^{-1}}. The precision of the cross-section measurements varies between 0.8% to 1.5% as a function of the pseudorapidity, excluding the 1.9% uncertainty on the integrated luminosity. The charge asymmetry is measured with an uncertainty between 0.002 and 0.003. The results are compared with predictions based on next-to-next-to-leading-order calculations with various parton distribution functions and have the sensitivity to discriminate between them.Comment: 38 pages in total, author list starting page 22, 5 figures, 4 tables, submitted to EPJC. All figures including auxiliary figures are available at https://atlas.web.cern.ch/Atlas/GROUPS/PHYSICS/PAPERS/STDM-2017-13

    Single hadron response measurement and calorimeter jet energy scale uncertainty with the ATLAS detector at the LHC

    Get PDF
    The uncertainty on the calorimeter energy response to jets of particles is derived for the ATLAS experiment at the Large Hadron Collider (LHC). First, the calorimeter response to single isolated charged hadrons is measured and compared to the Monte Carlo simulation using proton-proton collisions at centre-of-mass energies of sqrt(s) = 900 GeV and 7 TeV collected during 2009 and 2010. Then, using the decay of K_s and Lambda particles, the calorimeter response to specific types of particles (positively and negatively charged pions, protons, and anti-protons) is measured and compared to the Monte Carlo predictions. Finally, the jet energy scale uncertainty is determined by propagating the response uncertainty for single charged and neutral particles to jets. The response uncertainty is 2-5% for central isolated hadrons and 1-3% for the final calorimeter jet energy scale.Comment: 24 pages plus author list (36 pages total), 23 figures, 1 table, submitted to European Physical Journal

    Standalone vertex finding in the ATLAS muon spectrometer

    Get PDF
    A dedicated reconstruction algorithm to find decay vertices in the ATLAS muon spectrometer is presented. The algorithm searches the region just upstream of or inside the muon spectrometer volume for multi-particle vertices that originate from the decay of particles with long decay paths. The performance of the algorithm is evaluated using both a sample of simulated Higgs boson events, in which the Higgs boson decays to long-lived neutral particles that in turn decay to bbar b final states, and pp collision data at √s = 7 TeV collected with the ATLAS detector at the LHC during 2011

    Measurements of Higgs boson production and couplings in diboson final states with the ATLAS detector at the LHC

    Get PDF
    Measurements are presented of production properties and couplings of the recently discovered Higgs boson using the decays into boson pairs, H →γ γ, H → Z Z∗ →4l and H →W W∗ →lνlν. The results are based on the complete pp collision data sample recorded by the ATLAS experiment at the CERN Large Hadron Collider at centre-of-mass energies of √s = 7 TeV and √s = 8 TeV, corresponding to an integrated luminosity of about 25 fb−1. Evidence for Higgs boson production through vector-boson fusion is reported. Results of combined fits probing Higgs boson couplings to fermions and bosons, as well as anomalous contributions to loop-induced production and decay modes, are presented. All measurements are consistent with expectations for the Standard Model Higgs boson

    Measurement of the top quark-pair production cross section with ATLAS in pp collisions at \sqrt{s}=7\TeV

    Get PDF
    A measurement of the production cross-section for top quark pairs(\ttbar) in pppp collisions at \sqrt{s}=7 \TeV is presented using data recorded with the ATLAS detector at the Large Hadron Collider. Events are selected in two different topologies: single lepton (electron ee or muon μ\mu) with large missing transverse energy and at least four jets, and dilepton (eeee, μμ\mu\mu or eμe\mu) with large missing transverse energy and at least two jets. In a data sample of 2.9 pb-1, 37 candidate events are observed in the single-lepton topology and 9 events in the dilepton topology. The corresponding expected backgrounds from non-\ttbar Standard Model processes are estimated using data-driven methods and determined to be 12.2±3.912.2 \pm 3.9 events and 2.5±0.62.5 \pm 0.6 events, respectively. The kinematic properties of the selected events are consistent with SM \ttbar production. The inclusive top quark pair production cross-section is measured to be \sigmattbar=145 \pm 31 ^{+42}_{-27} pb where the first uncertainty is statistical and the second systematic. The measurement agrees with perturbative QCD calculations.Comment: 30 pages plus author list (50 pages total), 9 figures, 11 tables, CERN-PH number and final journal adde
    corecore