492 research outputs found

    Open Gromov-Witten Invariants of Toric Calabi-Yau 3-Folds

    Full text link
    We present a proof of the mirror conjecture of Aganagic-Vafa [arXiv:hep-th/0012041] and Aganagic-Klemm-Vafa [arXiv:hep-th/0105045] on disk enumeration in toric Calabi-Yau 3-folds for all smooth semi-projective toric Calabi-Yau 3-folds. We consider both inner and outer branes, at arbitrary framing. In particular, we recover previous results on the conjecture for (i) an inner brane at zero framing in the total space of the canonical line bundle of the projective plane (Graber-Zaslow [arXiv:hep-th/0109075]), (ii) an outer brane at arbitrary framing in the resolved conifold (Zhou [arXiv:1001.0447]), and (iii) an outer brane at zero framing in the total space of the canonical line bundle of the projective plane (Brini [arXiv:1102.0281, Section 5.3]).Comment: 39 pages, 11 figure

    Chromosomal aberrations in mouse lymphocytes exposed in vitro and in vivo to benzidine and 5 related aromatic amines

    Full text link
    Mouse lymphocytes were exposed in vitro for 2 h or in vivo for 24 h to benzidine and related aromatic amines to test for chromosome aberrations (CA) and mitotic indices. Uninduced mouse S9 was used to activate the amines for the in vitro tests to be consistent with the in vivo tests. Contrary to a previous report, no difference could be established in the genotoxicity of benzidine following activation with uninduced S9 compared to induced S9. There were concentration related increases in CA for benzidine and all the amines in vitro except for 4,4'-diaminostilbene which exhibited the greatest cellular toxicity towards cultured lymphocytes. Benzidine and its derivatives showed significant increases in CA in vivo compared to its negative control. The CA values for 4-aminostilbene were significantly higher than the other amines in both in vivo and in vitro studies. These genotoxicity results for 4-aminostilbene are consistent with our previous report of the pronounced CA effects in murine bone-marrow cells but would not be predicted from Salmonella mutagenicity tests.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/31873/1/0000823.pd

    Off-pump coronary artery bypass grafting provides complete revascularization with reduced myocardial injury, transfusion requirements, and length of stay: A prospective randomized comparison of two hundred unselected patients undergoing off-pump versus conventional coronary artery bypass grafting

    Get PDF
    AbstractObjective: Retrospective comparisons of selected patients undergoing off-pump versus conventional on-pump coronary artery bypass grafting have yielded inconsistent results and raised concerns about completeness of revascularization in off-pump coronary artery bypass grafting. Methods: Two hundred unselected patients referred for elective primary coronary artery bypass grafting were randomly assigned to undergo off-pump coronary artery bypass grafting with an Octopus tissue stabilizer (Medtronic, Inc, Minneapolis, Minn) or conventional coronary artery bypass grafting with cardiopulmonary bypass by a single surgeon. Revascularization intent determined before random assignment was compared with the revascularization performed. All management followed strict, unbiased, criteria-driven protocols. Patients and nonoperative care providers were blinded to surgical group. Results: Baseline characteristics were similar. The number of grafts performed per patient (mean ± SD 3.39 ± 1.04 for off-pump coronary artery bypass grafting, 3.40 ± 1.08 for conventional coronary artery bypass grafting) and the index of completeness of revascularization (number of grafts performed/number of grafts intended, 1.00 ± 0.18 for off-pump coronary artery bypass grafting, 1.01 ± 0.09 for conventional coronary artery bypass grafting) were similar. Likewise, the index of completeness of revascularization was similar between groups for the lateral wall. Combined hospital and 30-day mortalities and stroke rates were similar. Postoperative myocardial serum enzyme measures were significantly lower after off-pump coronary artery bypass grafting, suggesting less myocardial injury. Adjusted postoperative thromboelastogram indices, fibrinogen, international normalized ratio, and platelet levels all showed significantly less coagulopathy after off-pump coronary artery bypass grafting. Patients undergoing off-pump coronary artery bypass grafting received fewer units of blood, were more likely to avoid transfusion altogether, and had a higher hematocrit at discharge. Cardiopulmonary bypass was an independent predictor of transfusion (odds ratio 2.42, P =.0073) by multivariate analysis. More patients undergoing off-pump coronary artery bypass grafting were extubated in the operating room and within 4 hours. Postoperative length of stay (in days) was shorter for off-pump coronary artery bypass grafting (5.1 ± 6.5 for off-pump coronary artery bypass grafting, 6.1 ± 8.2 for conventional coronary artery bypass grafting, P =.005 by Wilcoxon test). One patient (in the conventional coronary artery bypass grafting group) required angioplasty for graft closure within 30 days. Conclusions: When compared with conventional coronary artery bypass grafting with cardiopulmonary bypass, off-pump coronary artery bypass grafting achieved similar completeness of revascularization, similar in-hospital and 30-day outcomes, shorter length of stay, reduced transfusion requirement, and less myocardial injury.J Thorac Cardiovasc Surg 2003;125:797-80

    Off-pump coronary artery bypass grafting provides complete revascularization with reduced myocardial injury, transfusion requirements, and length of stay: A prospective randomized comparison of two hundred unselected patients undergoing off-pump versus conventional coronary artery bypass grafting

    Get PDF
    AbstractObjective: Retrospective comparisons of selected patients undergoing off-pump versus conventional on-pump coronary artery bypass grafting have yielded inconsistent results and raised concerns about completeness of revascularization in off-pump coronary artery bypass grafting. Methods: Two hundred unselected patients referred for elective primary coronary artery bypass grafting were randomly assigned to undergo off-pump coronary artery bypass grafting with an Octopus tissue stabilizer (Medtronic, Inc, Minneapolis, Minn) or conventional coronary artery bypass grafting with cardiopulmonary bypass by a single surgeon. Revascularization intent determined before random assignment was compared with the revascularization performed. All management followed strict, unbiased, criteria-driven protocols. Patients and nonoperative care providers were blinded to surgical group. Results: Baseline characteristics were similar. The number of grafts performed per patient (mean ± SD 3.39 ± 1.04 for off-pump coronary artery bypass grafting, 3.40 ± 1.08 for conventional coronary artery bypass grafting) and the index of completeness of revascularization (number of grafts performed/number of grafts intended, 1.00 ± 0.18 for off-pump coronary artery bypass grafting, 1.01 ± 0.09 for conventional coronary artery bypass grafting) were similar. Likewise, the index of completeness of revascularization was similar between groups for the lateral wall. Combined hospital and 30-day mortalities and stroke rates were similar. Postoperative myocardial serum enzyme measures were significantly lower after off-pump coronary artery bypass grafting, suggesting less myocardial injury. Adjusted postoperative thromboelastogram indices, fibrinogen, international normalized ratio, and platelet levels all showed significantly less coagulopathy after off-pump coronary artery bypass grafting. Patients undergoing off-pump coronary artery bypass grafting received fewer units of blood, were more likely to avoid transfusion altogether, and had a higher hematocrit at discharge. Cardiopulmonary bypass was an independent predictor of transfusion (odds ratio 2.42, P =.0073) by multivariate analysis. More patients undergoing off-pump coronary artery bypass grafting were extubated in the operating room and within 4 hours. Postoperative length of stay (in days) was shorter for off-pump coronary artery bypass grafting (5.1 ± 6.5 for off-pump coronary artery bypass grafting, 6.1 ± 8.2 for conventional coronary artery bypass grafting, P =.005 by Wilcoxon test). One patient (in the conventional coronary artery bypass grafting group) required angioplasty for graft closure within 30 days. Conclusions: When compared with conventional coronary artery bypass grafting with cardiopulmonary bypass, off-pump coronary artery bypass grafting achieved similar completeness of revascularization, similar in-hospital and 30-day outcomes, shorter length of stay, reduced transfusion requirement, and less myocardial injury.J Thorac Cardiovasc Surg 2003;125:797-80

    Measurement of the polarisation of W bosons produced with large transverse momentum in pp collisions at sqrt(s) = 7 TeV with the ATLAS experiment

    Get PDF
    This paper describes an analysis of the angular distribution of W->enu and W->munu decays, using data from pp collisions at sqrt(s) = 7 TeV recorded with the ATLAS detector at the LHC in 2010, corresponding to an integrated luminosity of about 35 pb^-1. Using the decay lepton transverse momentum and the missing transverse energy, the W decay angular distribution projected onto the transverse plane is obtained and analysed in terms of helicity fractions f0, fL and fR over two ranges of W transverse momentum (ptw): 35 < ptw < 50 GeV and ptw > 50 GeV. Good agreement is found with theoretical predictions. For ptw > 50 GeV, the values of f0 and fL-fR, averaged over charge and lepton flavour, are measured to be : f0 = 0.127 +/- 0.030 +/- 0.108 and fL-fR = 0.252 +/- 0.017 +/- 0.030, where the first uncertainties are statistical, and the second include all systematic effects.Comment: 19 pages plus author list (34 pages total), 9 figures, 11 tables, revised author list, matches European Journal of Physics C versio

    Observation of a new chi_b state in radiative transitions to Upsilon(1S) and Upsilon(2S) at ATLAS

    Get PDF
    The chi_b(nP) quarkonium states are produced in proton-proton collisions at the Large Hadron Collider (LHC) at sqrt(s) = 7 TeV and recorded by the ATLAS detector. Using a data sample corresponding to an integrated luminosity of 4.4 fb^-1, these states are reconstructed through their radiative decays to Upsilon(1S,2S) with Upsilon->mu+mu-. In addition to the mass peaks corresponding to the decay modes chi_b(1P,2P)->Upsilon(1S)gamma, a new structure centered at a mass of 10.530+/-0.005 (stat.)+/-0.009 (syst.) GeV is also observed, in both the Upsilon(1S)gamma and Upsilon(2S)gamma decay modes. This is interpreted as the chi_b(3P) system.Comment: 5 pages plus author list (18 pages total), 2 figures, 1 table, corrected author list, matches final version in Physical Review Letter

    Search for displaced vertices arising from decays of new heavy particles in 7 TeV pp collisions at ATLAS

    Get PDF
    We present the results of a search for new, heavy particles that decay at a significant distance from their production point into a final state containing charged hadrons in association with a high-momentum muon. The search is conducted in a pp-collision data sample with a center-of-mass energy of 7 TeV and an integrated luminosity of 33 pb^-1 collected in 2010 by the ATLAS detector operating at the Large Hadron Collider. Production of such particles is expected in various scenarios of physics beyond the standard model. We observe no signal and place limits on the production cross-section of supersymmetric particles in an R-parity-violating scenario as a function of the neutralino lifetime. Limits are presented for different squark and neutralino masses, enabling extension of the limits to a variety of other models.Comment: 8 pages plus author list (20 pages total), 8 figures, 1 table, final version to appear in Physics Letters

    Measurement of the inclusive isolated prompt photon cross-section in pp collisions at sqrt(s)= 7 TeV using 35 pb-1 of ATLAS data

    Get PDF
    A measurement of the differential cross-section for the inclusive production of isolated prompt photons in pp collisions at a center-of-mass energy sqrt(s) = 7 TeV is presented. The measurement covers the pseudorapidity ranges |eta|<1.37 and 1.52<=|eta|<2.37 in the transverse energy range 45<=E_T<400GeV. The results are based on an integrated luminosity of 35 pb-1, collected with the ATLAS detector at the LHC. The yields of the signal photons are measured using a data-driven technique, based on the observed distribution of the hadronic energy in a narrow cone around the photon candidate and the photon selection criteria. The results are compared with next-to-leading order perturbative QCD calculations and found to be in good agreement over four orders of magnitude in cross-section.Comment: 7 pages plus author list (18 pages total), 2 figures, 4 tables, final version published in Physics Letters

    Search for direct production of charginos and neutralinos in events with three leptons and missing transverse momentum in √s = 7 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for the direct production of charginos and neutralinos in final states with three electrons or muons and missing transverse momentum is presented. The analysis is based on 4.7 fb−1 of proton–proton collision data delivered by the Large Hadron Collider and recorded with the ATLAS detector. Observations are consistent with Standard Model expectations in three signal regions that are either depleted or enriched in Z-boson decays. Upper limits at 95% confidence level are set in R-parity conserving phenomenological minimal supersymmetric models and in simplified models, significantly extending previous results

    Jet size dependence of single jet suppression in lead-lead collisions at sqrt(s(NN)) = 2.76 TeV with the ATLAS detector at the LHC

    Get PDF
    Measurements of inclusive jet suppression in heavy ion collisions at the LHC provide direct sensitivity to the physics of jet quenching. In a sample of lead-lead collisions at sqrt(s) = 2.76 TeV corresponding to an integrated luminosity of approximately 7 inverse microbarns, ATLAS has measured jets with a calorimeter over the pseudorapidity interval |eta| < 2.1 and over the transverse momentum range 38 < pT < 210 GeV. Jets were reconstructed using the anti-kt algorithm with values for the distance parameter that determines the nominal jet radius of R = 0.2, 0.3, 0.4 and 0.5. The centrality dependence of the jet yield is characterized by the jet "central-to-peripheral ratio," Rcp. Jet production is found to be suppressed by approximately a factor of two in the 10% most central collisions relative to peripheral collisions. Rcp varies smoothly with centrality as characterized by the number of participating nucleons. The observed suppression is only weakly dependent on jet radius and transverse momentum. These results provide the first direct measurement of inclusive jet suppression in heavy ion collisions and complement previous measurements of dijet transverse energy imbalance at the LHC.Comment: 15 pages plus author list (30 pages total), 8 figures, 2 tables, submitted to Physics Letters B. All figures including auxiliary figures are available at http://atlas.web.cern.ch/Atlas/GROUPS/PHYSICS/PAPERS/HION-2011-02
    corecore