166 research outputs found

    Design and manufacture of a customised temporomandibular prosthesis

    Get PDF
    In this work, design, manufacture and surgical success of a personalised temporomandibular prosthesis is featured. A fused deposition modelling technique and Die forging process constitute the methodology used in a patient who had an amputation in the upper third branch of the mandible, without considering the joint capsule. The implant was designed using a processed resection image of a computational tomography and using the methodology of Özkaya and Nordin. The jaw operating conditions were simulated by the finite element method (FEM). The main considered factors were the morphological geometry of the patient, implant fixation in the first third of the branch, implant fixation on the chin, dental post for placement of the teeth, and the form of the sub-lingual fossa weight optimisation. Special consideration was to preserve the patients facial aesthetics.Peer Reviewe

    Estudio de valoración del dolor en pacientes con fractura-luxación de Lisfranc

    Get PDF
    Objetivo: Cuantificar la presencia de dolor y pérdida de calidad de vida secundaria a la fractura-luxación de Lisfranc. Material y Métodos: Realizamos un estudio de cohortes transversal de 83 pacientes con diagnostico de fractura-luxación de Lisfranc. La presencia de dolor en reposo y en actividad se valoró mediante la aplicación de la Escala Visual Analógica (EVA) y el cuestionario de calidad de vida Espiditest. Resultados: La edad media de los pacientes estudiados fue de 38,36 años. No se detectaron diferencias en las puntuaciones por sexo y edad. No se encontró asociación entre calidad de vida en Espiditest y el tipo de tratamiento empleado, la cirugía precoz y su duración. Existía mayor consumo de analgésicos para control del dolor y más dificultad para regresar a su empleo o actividad laboral previa a la lesión en pacientes que presentaban peor calidad de vida en Espiditest. El grado de satisfacción por parte de los pacientes fue concordante con la calidad de vida. Conclusiones: La fractura-luxación de Lisfranc a pesar de ser una lesión incapacitante, no es tan limitante para la calidad de vida por causa del dolor.Objetives: To quantify the presence of pain and to determine loss of quality of life after a Lisfranc fracture-dislocation. Material and methods: We conducted a cross-sectional cohort study in 83 patients diagnosed with Lisfranc fracture-dislocation. The presence of pain at rest and during activity was assessed by means of a visual analogy scale (VAS) and the quality of life questionnaire Espiditest. Results: Patients in the study have a mean age of 38,36 years. The study results are not skewed by sex or gender of participants. No association whatsoever was found between the quality of life - according to the Espiditest - and the type of treatment being used, neither the early surgery nor the length of it. Patients with poorer quality of life - as shown in Espiditest - have a higher consumption of analgesics used for pain relief and more difficulty returning to their job or work activity prior to the injury. The degree of satisfaction by patients was consistent with the quality of their life. Conclusions: The Lisfranc fracture-dislocation, despite being a disabling injury, does not limit the quality of life because of pain

    Evaluación urodinámica y comparativa de la calidad de vida en pacientes con trastorno de vaciamiento vesical sometidos a terapia InterStim, Medtronic®

    Get PDF
    ResumenAntecedentesDesde 1980 la terapia de neuroestimulación sacra ha demostrado ser una terapia válida y alternativa en el manejo de los trastornos miccionales por patología del tracto urinario bajo, siendo sus principales indicaciones la retención urinaria idiopática, la incontinencia de urgencia y la incontinencia fecal. En nuestro país sigue siendo una terapia novedosa y no se cuenta aún con estudios que evalúen esta eficacia en términos de calidad de vida o con parámetros cuantitativos.Objetivo del estudioEstablecer la eficacia de la terapia de neuroestimulación sacra tipo InterStim, Medtronic®, en el manejo de los pacientes con trastornos de vaciamiento vesical, efectuando un análisis urodinámico y de la calidad de vida comparativo previo y posterior al tratamiento, determinando los volúmenes miccionales, los períodos de incontinencia, la satisfacción del paciente y la calidad de vida.Material y métodosDesde enero de 2010 hasta junio de 2013, en el Hospital Central Militar se realizó evaluación urodinámica y comparativa de la calidad de vida mediante el empleo del instrumento SF-36 v2 (versión mexicana) e ICIQSF, en los pacientes que presentaron trastorno de vaciamiento vesical de etiología no obstructiva y que fueron refractarios a tratamiento médico.ResultadosSe incluyeron 10 pacientes en el estudio, bajo los siguientes diagnósticos: disinergia detrusor-esfínter, vejiga hiperactiva y retención urinaria no obstructiva, ubicados por género (2 masculinos y 8 femeninos). En la totalidad de los pacientes se presentó mejoría del 50% o superior durante la fase de prueba de la terapia de neuroestimulación, y se colocó fase definitiva con los siguientes resultados: se obtuvieron resultados equivalentes al 50-65% de mejoría en los parámetros cualitativos de función física, función social y rol emocional, así como en las variables cuantitativas de volumen de vaciamiento, eficacia de vaciamiento y disminución de los períodos de incontinencia.DiscusiónComo se ha establecido a nivel de la literatura mundial, nuestros resultados fueron similares en el efecto benéfico y la eficacia en la calidad de vida e incontinencia urinaria, respectivamente, y se reportan porcentajes de éxito mayores al 50% en el cese total de los episodios de incontinencia.ConclusionesLa neuromodulación mediante la estimulación del nervio sacro es una forma exitosa de tratamiento en los trastornos de vaciamiento vesical de etiología no obstructiva y refractaria al tratamiento médico, es segura, mínimamente invasiva y de fácil aplicación, y mejora la calidad de vida de los pacientes. Sin embargo, es necesario realizar estudios aleatorizados y que consideren parámetros objetivos (urodinámicos), así como las complicaciones posibles a mediano y largo plazo en este tipo de terapia.AbstractBackgroundSince 1980, sacral neuromodulation therapy has been shown to be a valid alternative therapy in the management of urinary disorders due to lower urinary tract pathology, and its primary indications are: idiopathic urinary retention, urge incontinence, and fecal incontinence. It is still considered a novel therapy in Mexico and there are no studies using quantitative parameters that evaluate its efficacy in terms of quality of life.AimsTo establish the efficacy of the Medtronic InterStim® sacral neuromodulation therapy in the management of patients with bladder voiding disorders through urodynamic and quality of life analyses before and after treatment. Urine volume, periods of incontinence, patient satisfaction, and quality of life were determined.MethodsA comparative urodynamic and quality of life evaluation was carried out using the SF-36 v2 (Mexican version) and the ICIQSF instruments on patients presenting with nonobstructive bladder voiding disorders that were refractory to medical treatment.ResultsTen patients with the following diagnoses were included in the study: detrusor sphincter dyssynergia, overactive bladder, and nonobstructive urinary retention. Two of the patients were men and 8 were women. There was a 50% or greater improvement in all 10 patients during the test phase of the neuromodulation therapy and the definitive placement phase produced the following results: a 50-65% improvement in the qualitative parameters of physical function, social function, and emotional role, as well as in the quantitative variables of voiding volume, voiding efficacy, and reduced periods of incontinence.DiscussionOur results were similar to those established in the international literature in relation to the beneficial effect on quality of life and efficacy in urinary incontinence management; the literature reports success percentages in the complete cessation of incontinence episodes at above 50%.ConclusionsNeuromodulation through sacral nerve stimulation is a successful form of treatment of nonobstructive and medical treatment-refractory bladder voiding disorders. It is safe, minimally invasive, and easy to apply and it improves patient quality of life. Nevertheless, further randomized studies on this type of therapy need to be conducted that take into account objective parameters (urodynamics) and possible medium and long-term complications

    Distribution and outcomes of a phenotype-based approach to guide COPD management: Results from the CHAIN cohort

    Get PDF
    Rationale: The Spanish guideline for COPD (GesEPOC) recommends COPD treatment according to four clinical phenotypes: non-exacerbator phenotype with either chronic bronchitis or emphysema (NE), asthma-COPD overlap syndrome (ACOS), frequent exacerbator phenotype with emphysema (FEE) or frequent exacerbator phenotype with chronic bronchitis (FECB). However, little is known on the distribution and outcomes of the four suggested phenotypes. Objective: We aimed to determine the distribution of these COPD phenotypes, and their relation with one-year clinical outcomes. Methods: We followed a cohort of well-characterized patients with COPD up to one-year. Baseline characteristics, health status (CAT), BODE index, rate of exacerbations and mortality up to one year of follow-up were compared between the four phenotypes. Results: Overall, 831 stable COPD patients were evaluated. They were distributed as NE, 550 (66.2%); ACOS, 125 (15.0%); FEE, 38 (4.6%); and FECB, 99 (11.9%); additionally 19 (2.3%) COPD patients with frequent exacerbations did not fulfill the criteria for neither FEE nor FECB. At baseline, there were significant differences in symptoms, FEV1 and BODE index (all p<0.05). The FECB phenotype had the highest CAT score (17.1±8.2, p<0.05 compared to the other phenotypes). Frequent exacerbator groups (FEE and FECB) were receiving more pharmacological treatment at baseline, and also experienced more exacerbations the year after (all p<0.05) with no differences in one-year mortality. Most of NE (93%) and half of exacerbators were stable after one year. Conclusions: There is an uneven distribution of COPD phenotypes in stable COPD patients, with significant differences in demographics, patient-centered outcomes and health care resources use

    Evidence for a mixed mass composition at the `ankle' in the cosmic-ray spectrum

    Get PDF
    We report a first measurement for ultra-high energy cosmic rays of the correlation between the depth of shower maximum and the signal in the water Cherenkov stations of air-showers registered simultaneously by the fluorescence and the surface detectors of the Pierre Auger Observatory. Such a correlation measurement is a unique feature of a hybrid air-shower observatory with sensitivity to both the electromagnetic and muonic components. It allows an accurate determination of the spread of primary masses in the cosmic-ray flux. Up till now, constraints on the spread of primary masses have been dominated by systematic uncertainties. The present correlation measurement is not affected by systematics in the measurement of the depth of shower maximum or the signal in the water Cherenkov stations. The analysis relies on general characteristics of air showers and is thus robust also with respect to uncertainties in hadronic event generators. The observed correlation in the energy range around the `ankle' at lg(E/eV)=18.519.0\lg(E/{\rm eV})=18.5-19.0 differs significantly from expectations for pure primary cosmic-ray compositions. A light composition made up of proton and helium only is equally inconsistent with observations. The data are explained well by a mixed composition including nuclei with mass A>4A > 4. Scenarios such as the proton dip model, with almost pure compositions, are thus disfavoured as the sole explanation of the ultrahigh-energy cosmic-ray flux at Earth.Comment: Published version. Added journal reference and DOI. Added Report Numbe

    Atmospheric effects on extensive air showers observed with the Surface Detector of the Pierre Auger Observatory

    Get PDF
    Atmospheric parameters, such as pressure (P), temperature (T) and density, affect the development of extensive air showers initiated by energetic cosmic rays. We have studied the impact of atmospheric variations on extensive air showers by means of the surface detector of the Pierre Auger Observatory. The rate of events shows a ~10% seasonal modulation and ~2% diurnal one. We find that the observed behaviour is explained by a model including the effects associated with the variations of pressure and density. The former affects the longitudinal development of air showers while the latter influences the Moliere radius and hence the lateral distribution of the shower particles. The model is validated with full simulations of extensive air showers using atmospheric profiles measured at the site of the Pierre Auger Observatory.Comment: 24 pages, 9 figures, accepted for publication in Astroparticle Physic

    The Fluorescence Detector of the Pierre Auger Observatory

    Get PDF
    The Pierre Auger Observatory is a hybrid detector for ultra-high energy cosmic rays. It combines a surface array to measure secondary particles at ground level together with a fluorescence detector to measure the development of air showers in the atmosphere above the array. The fluorescence detector comprises 24 large telescopes specialized for measuring the nitrogen fluorescence caused by charged particles of cosmic ray air showers. In this paper we describe the components of the fluorescence detector including its optical system, the design of the camera, the electronics, and the systems for relative and absolute calibration. We also discuss the operation and the monitoring of the detector. Finally, we evaluate the detector performance and precision of shower reconstructions.Comment: 53 pages. Submitted to Nuclear Instruments and Methods in Physics Research Section

    A First Search for coincident Gravitational Waves and High Energy Neutrinos using LIGO, Virgo and ANTARES data from 2007

    Get PDF
    We present the results of the first search for gravitational wave bursts associated with high energy neutrinos. Together, these messengers could reveal new, hidden sources that are not observed by conventional photon astronomy, particularly at high energy. Our search uses neutrinos detected by the underwater neutrino telescope ANTARES in its 5 line configuration during the period January - September 2007, which coincided with the fifth and first science runs of LIGO and Virgo, respectively. The LIGO-Virgo data were analysed for candidate gravitational-wave signals coincident in time and direction with the neutrino events. No significant coincident events were observed. We place limits on the density of joint high energy neutrino - gravitational wave emission events in the local universe, and compare them with densities of merger and core-collapse events.Comment: 19 pages, 8 figures, science summary page at http://www.ligo.org/science/Publication-S5LV_ANTARES/index.php. Public access area to figures, tables at https://dcc.ligo.org/cgi-bin/DocDB/ShowDocument?docid=p120000

    The Mars Environmental Dynamics Analyzer, MEDA. A Suite of Environmental Sensors for the Mars 2020 Mission

    Get PDF
    86 pags., 49 figs., 24 tabs.NASA’s Mars 2020 (M2020) rover mission includes a suite of sensors to monitor current environmental conditions near the surface of Mars and to constrain bulk aerosol properties from changes in atmospheric radiation at the surface. The Mars Environmental Dynamics Analyzer (MEDA) consists of a set of meteorological sensors including wind sensor, a barometer, a relative humidity sensor, a set of 5 thermocouples to measure atmospheric temperature at ∼1.5 m and ∼0.5 m above the surface, a set of thermopiles to characterize the thermal IR brightness temperatures of the surface and the lower atmosphere. MEDA adds a radiation and dust sensor to monitor the optical atmospheric properties that can be used to infer bulk aerosol physical properties such as particle size distribution, non-sphericity, and concentration. The MEDA package and its scientific purpose are described in this document as well as how it responded to the calibration tests and how it helps prepare for the human exploration of Mars. A comparison is also presented to previous environmental monitoring payloads landed on Mars on the Viking, Pathfinder, Phoenix, MSL, and InSight spacecraft.This work has been funded by the Spanish Ministry of Economy and Competitiveness, through the projects No. ESP2014-54256-C4-1-R (also -2-R, -3-R and -4-R) and AYA2015-65041-P; Ministry of Science, Innovation and Universities, projects No. ESP2016-79612-C3-1-R (also -2-R and -3-R), ESP2016-80320-C2-1-R, RTI2018-098728-B-C31 (also -C32 and -C33) and RTI2018-099825-B-C31; Instituto Nacional de Técnica Aeroespacial; Ministry of Science and Innovation’s Centre for the Development of Industrial Technology; Grupos Gobierno Vasco IT1366-19; and European Research Council Consolidator Grant no 818602. The US co-authors performed their work under sponsorship from NASA’s Mars 2020 project, from the Game Changing Development program within the Space Technology Mission Directorate and from the Human Exploration and Operations Directorate

    Spread of a SARS-CoV-2 variant through Europe in the summer of 2020.

    Get PDF
    Following its emergence in late 2019, the spread of SARS-CoV-21,2 has been tracked by phylogenetic analysis of viral genome sequences in unprecedented detail3–5. Although the virus spread globally in early 2020 before borders closed, intercontinental travel has since been greatly reduced. However, travel within Europe resumed in the summer of 2020. Here we report on a SARS-CoV-2 variant, 20E (EU1), that was identified in Spain in early summer 2020 and subsequently spread across Europe. We find no evidence that this variant has increased transmissibility, but instead demonstrate how rising incidence in Spain, resumption of travel, and lack of effective screening and containment may explain the variant’s success. Despite travel restrictions, we estimate that 20E (EU1) was introduced hundreds of times to European countries by summertime travellers, which is likely to have undermined local efforts to minimize infection with SARS-CoV-2. Our results illustrate how a variant can rapidly become dominant even in the absence of a substantial transmission advantage in favourable epidemiological settings. Genomic surveillance is critical for understanding how travel can affect transmission of SARS-CoV-2, and thus for informing future containment strategies as travel resumes. © 2021, The Author(s), under exclusive licence to Springer Nature Limited
    corecore