841 research outputs found

    Lymph Node Negative Colorectal Cancers with Isolated Tumor Deposits Should Be Classified and Treated As Stage III

    Get PDF
    BACKGROUND: The prognostic role of pericolic or perirectal isolated tumor deposits (ITDs) in node-negative colorectal cancer (CRC) patients is unclear. Rules to define ITDs as regional lymph node metastases changed in subsequent editions of the TNM staging without substantial evidence. Aim of this study was to investigate the correlation between ITDs and disease recurrence in stage II and III CRC patients. MATERIALS AND METHODS: The medical files of 870 CRC patients were reviewed. Number, size, shape, and location pattern of all ITDs in node-negative patients were examined in relation to involvement of vascular structures and nerves. The correlation between ITDs and the development of recurrent disease was investigated. RESULTS: Disease recurrence was observed in 50.0% of stage II patients with ITDs (13 of 26), compared with 24.4% of stage II patients without ITDs (66 of 270) (P <.01). Disease-free survival of ITD-positive stage II patients was comparable with that of stage III patients. Also within stage III, more recurrences were observed in ITD-positive patients compared with ITD-negative patients (65.1 vs. 39.1%, respectively). No correlation was found between size of ITDs and disease recurrence. More recurrences were seen in patients with irregularly shaped ITDs compared with patients with 1 or more smooth ITDs present. CONCLUSIONS: Because of the high risk of disease recurrence, all node-negative stage II patients with ITDs, regardless of size and shape, should be classified as stage III, for whom adjuvant chemotherapy should be considere

    The XMM-SSC survey of hard-spectrum XMM-Newton sources 1: optically bright sources

    Full text link
    We present optical and X-ray data for a sample of serendipitous XMM-Newton sources that are selected to have 0.5-2 keV vs 2-4.5 keV X-ray hardness ratios which are harder than the X-ray background. The sources have 2-4.5 keV X-ray flux >= 10^-14 cgs, and in this paper we examine a subsample of 42 optically bright (r < 21) sources; this subsample is 100 per cent spectroscopically identified. All but one of the optical counterparts are extragalactic, and we argue that the single exception, a Galactic M star, is probably a coincidental association. The X-ray spectra are consistent with heavily absorbed power laws (21.8 < log NH < 23.4), and all of them appear to be absorbed AGN. The majority of the sources show only narrow emission lines in their optical spectra, implying that they are type-2 AGN. Only a small fraction of the sources (7/42) show broad optical emission lines, and all of these have NH < 10^23 cm^-2. This implies that ratios of X-ray absorption to optical/UV extinction equivalent to > 100 times the Galactic gas-to-dust ratio are rare in AGN absorbers (at most a few percent of the population), and may be restricted to broad absorption-line QSOs. Seven objects appear to have an additional soft X-ray component in addition to the heavily absorbed power law. We consider the implications of our results in the light of the AGN unified scheme. We find that the soft components in narrow-line objects are consistent with the unified scheme provided that > 4 per cent of broad-line AGN have ionised absorbers that attenuate their soft X-ray flux by >50 per cent. In at least one of the X-ray absorbed, broad-line AGN in our sample the X-ray spectrum requires an ionised absorber, consistent with this picture.Comment: accepted for publication in MNRA

    The Rewiring of Ubiquitination Targets in a Pathogenic Yeast Promotes Metabolic Flexibility, Host Colonization and Virulence

    Get PDF
    Funding: This work was funded by the European Research Council [http://erc.europa.eu/], AJPB (STRIFE Advanced Grant; C-2009-AdG-249793). The work was also supported by: the Wellcome Trust [www.wellcome.ac.uk], AJPB (080088, 097377); the UK Biotechnology and Biological Research Council [www.bbsrc.ac.uk], AJPB (BB/F00513X/1, BB/K017365/1); the CNPq-Brazil [http://cnpq.br], GMA (Science without Borders fellowship 202976/2014-9); and the National Centre for the Replacement, Refinement and Reduction of Animals in Research [www.nc3rs.org.uk], DMM (NC/K000306/1). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. Acknowledgments We thank Dr. Elizabeth Johnson (Mycology Reference Laboratory, Bristol) for providing strains, and the Aberdeen Proteomics facility for the biotyping of S. cerevisiae clinical isolates, and to Euroscarf for providing S. cerevisiae strains and plasmids. We are grateful to our Microscopy Facility in the Institute of Medical Sciences for their expert help with the electron microscopy, and to our friends in the Aberdeen Fungal Group for insightful discussions.Peer reviewedPublisher PD

    Studies of the Decay B+- -> D_CP K+-

    Get PDF
    We report studies of the decay B+- -> D_CP K+-, where D_CP denotes neutral D mesons that decay to CP eigenstates. The analysis is based on a 29.1/fb data sample of collected at the \Upsilon(4S) resonance with the Belle detector at the KEKB asymmetric e+ e- storage ring. Ratios of branching fractions of Cabibbo-suppressed to Cabibbo-favored processes involving D_CP are determined to be B(B- -> D_1 K-)/B(B- -> D_1 pi-)=0.125 +- 0.036 +- 0.010 and B(B- -> D_2 K-)/B(B- -> D_2 pi-)=0.119 +- 0.028 +- 0.006, where indices 1 and 2 represent the CP=+1 and CP=-1 eigenstates of the D0 - anti D0 system, respectively. We also extract the partial rate asymmetries for B+- -> D_CP K+-, finding A_1 = 0.29 +- 0.26 +- 0.05 and A_2 = -0.22 +- 0.24 +- 0.04.Comment: 10 pages, 2 figures, submitted to Physical Review Letter

    The Increase in Balloon Size to Over 15 mm Does Not Affect the Development of Pancreatitis After Endoscopic Papillary Large Balloon Dilatation for Bile Duct Stone Removal

    Get PDF
    BACKGROUND: Endoscopic papillary large balloon dilatation (EPLBD) after endoscopic sphincterotomy (EST) has recently become widely used for common bile duct (CBD) stone removal, but many clinicians remain concerned about post-procedural pancreatitis with increasing the balloon size to over 15 mm. AIMS: We aimed to evaluate the safety and efficacy of EPLBD with a relatively large balloon (15-20 mm) after EST and to evaluate the factors related to post-EPLBD pancreatitis. METHODS: A retrospective review was undertaken of the endoscopic database of 101 patients with CBD stones who underwent EPLBD using a larger balloon size of over 15 mm (15-20 mm). Clinical parameters, endoscopic data, and outcomes were analyzed. RESULTS: The mean age of the subjects was 69 years. All patients had a dilated CBD of over 11 mm (mean = 22.6 mm). The mean size of balloon used in EPLBD was 17.1 ± 1.9 mm (range 15-20 mm). Mechanical lithotripsy was required in seven patients (6.9%). The rate of complete stone removal in the first session was 92.1%. Post-procedural pancreatitis developed in five cases (5.4%), but none were graded as severe. The smaller dilatation of the CBD, longer cannulation time, and longer time for stone removal were associated with post-procedural pancreatitis, but larger size of balloon did not affect the development of post-EPLBD pancreatitis. CONCLUSIONS: EPLBD with a large balloon of over 15 mm with EST is an effective and safe procedure with a very low probability of severe post-procedural pancreatitis. Post-EPLBD pancreatitis was not associated with larger balloon size, but was associated with longer procedure time and smaller dilatation of the CBD.ope

    Electric double-layer capacitance between an ionic liquid and few-layer graphene

    Get PDF
    Ionic-liquid gates have a high carrier density due to their atomically thin electric double layer (EDL) and extremely large geometrical capacitance C-g. However, a high carrier density in graphene has not been achieved even with ionic-liquid gates because the EDL capacitance C-EDL between the ionic liquid and graphene involves the series connection of C-g and the quantum capacitance C-q, which is proportional to the density of states. We investigated the variables that determine C-EDL at the molecular level by varying the number of graphene layers n and thereby optimising C-q. The C-EDL value is governed by C-q at n, 4, and by C-g at n > 4. This transition with n indicates a composite nature for C-EDL. Our finding clarifies a universal principle that determines capacitance on a microscopic scale, and provides nanotechnological perspectives on charge accumulation and energy storage using an ultimately thin capacitor

    Measurement of the inclusive and dijet cross-sections of b-jets in pp collisions at sqrt(s) = 7 TeV with the ATLAS detector

    Get PDF
    The inclusive and dijet production cross-sections have been measured for jets containing b-hadrons (b-jets) in proton-proton collisions at a centre-of-mass energy of sqrt(s) = 7 TeV, using the ATLAS detector at the LHC. The measurements use data corresponding to an integrated luminosity of 34 pb^-1. The b-jets are identified using either a lifetime-based method, where secondary decay vertices of b-hadrons in jets are reconstructed using information from the tracking detectors, or a muon-based method where the presence of a muon is used to identify semileptonic decays of b-hadrons inside jets. The inclusive b-jet cross-section is measured as a function of transverse momentum in the range 20 < pT < 400 GeV and rapidity in the range |y| < 2.1. The bbbar-dijet cross-section is measured as a function of the dijet invariant mass in the range 110 < m_jj < 760 GeV, the azimuthal angle difference between the two jets and the angular variable chi in two dijet mass regions. The results are compared with next-to-leading-order QCD predictions. Good agreement is observed between the measured cross-sections and the predictions obtained using POWHEG + Pythia. MC@NLO + Herwig shows good agreement with the measured bbbar-dijet cross-section. However, it does not reproduce the measured inclusive cross-section well, particularly for central b-jets with large transverse momenta.Comment: 10 pages plus author list (21 pages total), 8 figures, 1 table, final version published in European Physical Journal

    Measurement of χ c1 and χ c2 production with s√ = 7 TeV pp collisions at ATLAS

    Get PDF
    The prompt and non-prompt production cross-sections for the χ c1 and χ c2 charmonium states are measured in pp collisions at s√ = 7 TeV with the ATLAS detector at the LHC using 4.5 fb−1 of integrated luminosity. The χ c states are reconstructed through the radiative decay χ c → J/ψγ (with J/ψ → μ + μ −) where photons are reconstructed from γ → e + e − conversions. The production rate of the χ c2 state relative to the χ c1 state is measured for prompt and non-prompt χ c as a function of J/ψ transverse momentum. The prompt χ c cross-sections are combined with existing measurements of prompt J/ψ production to derive the fraction of prompt J/ψ produced in feed-down from χ c decays. The fractions of χ c1 and χ c2 produced in b-hadron decays are also measured
    corecore