199 research outputs found

    Monitoring Cross-Linking, the Evolution of Refractive Index and the Glass Transition Temperature of an Epoxy Resin Using an Optical Fiber Sensor

    Get PDF
    Hyphenated analytical techniques enable the simultaneous measurement of relevant processing and materials parameters under identical environmental conditions. In the current study, a power-compensated differential scanning calorimeter (DSC) was custom-modified to enable the integration of an optical fibre sensor to monitor in situ the progression of the cross-linking reactions by inferring the evolution of the refractive index. A cleaved optical fibre was used and it served as a Fresnel reflection sensor (FRS). The DSC was calibrated with and without the integrated FRS and it was demonstrated that it did not influence the performance of the DSC. The FRS was calibrated using reference refractive index oils within the DSC. An epoxy/amine resin system was cross-linked at 70 ^oC and the enthalpy of cross-linking and the evolution of the refractive index were monitored simultaneously using the DSC and FRS respectively. After the cross-linking was completed, the DSC was programmed to perform a ramped heating schedule from ambient temperature to 150 ^oC. The FRS was capable of detecting glass transition temperature (Tg) of the cross-linked resin. An excellent correlation was observed for the Tg obtained by the FRS and DSC. The contribution of factors affecting the resolution of the data from the FRS are discussed.</p

    Results of Prevention of REStenosis with Tranilast and its Outcomes (PRESTO) trial

    Get PDF
    BACKGROUND: Restenosis after percutaneous coronary intervention (PCI) is a major problem affecting 15% to 30% of patients after stent placement. No oral agent has shown a beneficial effect on restenosis or on associated major adverse cardiovascular events. In limited trials, the oral agent tranilast has been shown to decrease the frequency of angiographic restenosis after PCI. METHODS AND RESULTS: In this double-blind, randomized, placebo-controlled trial of tranilast (300 and 450 mg BID for 1 or 3 months), 11 484 patients were enrolled. Enrollment and drug were initiated within 4 hours after successful PCI of at least 1 vessel. The primary end point was the first occurrence of death, myocardial infarction, or ischemia-driven target vessel revascularization within 9 months and was 15.8% in the placebo group and 15.5% to 16.1% in the tranilast groups (P=0.77 to 0.81). Myocardial infarction was the only component of major adverse cardiovascular events to show some evidence of a reduction with tranilast (450 mg BID for 3 months): 1.1% versus 1.8% with placebo (P=0.061 for intent-to-treat population). The primary reason for not completing treatment was > or =1 hepatic laboratory test abnormality (11.4% versus 0.2% with placebo, P<0.01). In the angiographic substudy composed of 2018 patients, minimal lumen diameter (MLD) was measured by quantitative coronary angiography. At follow-up, MLD was 1.76+/-0.77 mm in the placebo group, which was not different from MLD in the tranilast groups (1.72 to 1.78+/-0.76 to 80 mm, P=0.49 to 0.89). In a subset of these patients (n=1107), intravascular ultrasound was performed at follow-up. Plaque volume was not different between the placebo and tranilast groups (39.3 versus 37.5 to 46.1 mm(3), respectively; P=0.16 to 0.72). CONCLUSIONS: Tranilast does not improve the quantitative measures of restenosis (angiographic and intravascular ultrasound) or its clinical sequelae

    Differences in Characteristics and Outcome of Patients with Penetrating Injuries in the USA and the Netherlands: A Multi-institutional Comparison

    Get PDF
    Introduction: The incidence and nature of penetrating injuries differ between countries. The aim of this study was to analyze characteristics and clinical outcomes of patients with penetrating injuries treated at urban Level-1 trauma centers in the USA (USTC) and the Netherlands (NLTC). Methods: In this retrospective cohort study, 1331 adult patients (470 from five NLTC and 861 from three USTC) with truncal penetrating injuries admitted between July 2011 and December 2014 were included. In-hospital mortality was the primary outcome. Outcome comparisons were adjusted for differences in population characteristics in multivariable analyses. Results: In USTC, gunshot wound injuries (36.1 vs. 17.4%, p < 0.001) and assaults were more frequent (91.2 vs. 77.7%, p < 0.001). ISS was higher in USTC, but the Revised Trauma Score (RTS) was comparable. In-hospital mortality was similar (5.0 vs. 3.6% in NLTC, p = 0.25). The adjusted odds ratio for mortality in USTC compared to NLTC was 0.95 (95% confidence interval 0.35–2.54). Hospital stay length of stay was shorter in USTC (difference 0.17 days, 95% CI −0.29 to −0.05, p = 0.005), ICU admission rate was comparable (OR 0.96, 95% CI 0.71–1.31, p = 0.80), and ICU length of stay was longer in USTC (difference of 0.39 days, 95% CI 0.18–0.60, p < 0.0001). More USTC patients were discharged to home (86.9 vs. 80.6%, p < 0.001). Readmission rates were similar (5.6 vs. 3.8%, p = 0.17). Conclusion: Despite the higher incidence of penetrating trauma, particularly firearm-related injuries, and higher hospital volumes in the USTC compared to the NLTC, the in-hospital mortality was similar. In this study, outcome of care was not significantly influenced by differences in incidence of firearm-related injuries

    Irish cardiac society - Proceedings of annual general meeting held 20th & 21st November 1992 in Dublin Castle

    Get PDF

    Search for supersymmetry at √S=8TeV in final states with jets and two same-sign leptons or three leptons with the ATLAS detector

    Get PDF
    A search for strongly produced supersymmetric particles is conducted using signatures involving multiple energetic jets and either two isolated leptons (e or ÎŒ) with the same electric charge, or at least three isolated leptons. The search also utilises jets originating from b-quarks, missing transverse momentum and other observables to extend its sensitivity. The analysis uses a data sample corresponding to a total integrated luminosity of 20.3 fb−1 of √s = 8 TeV proton-proton collisions recorded with the ATLAS detector at the Large Hadron Collider in 2012. No deviation from the Standard Model expectation is observed. New or significantly improved exclusion limits are set on a wide variety of supersymmetric models in which the lightest squark can be of the first, second or third generations, and in which R-parity can be conserved or violated

    Search for H→γγ produced in association with top quarks and constraints on the Yukawa coupling between the top quark and the Higgs boson using data taken at 7 TeV and 8 TeV with the ATLAS detector

    Get PDF
    A search is performed for Higgs bosons produced in association with top quarks using the diphoton decay mode of the Higgs boson. Selection requirements are optimized separately for leptonic and fully hadronic final states from the top quark decays. The dataset used corresponds to an integrated luminosity of 4.5 fb−14.5 fb−1 of proton–proton collisions at a center-of-mass energy of 7 TeV and 20.3 fb−1 at 8 TeV recorded by the ATLAS detector at the CERN Large Hadron Collider. No significant excess over the background prediction is observed and upper limits are set on the tt¯H production cross section. The observed exclusion upper limit at 95% confidence level is 6.7 times the predicted Standard Model cross section value. In addition, limits are set on the strength of the Yukawa coupling between the top quark and the Higgs boson, taking into account the dependence of the tt¯H and tH cross sections as well as the H→γγ branching fraction on the Yukawa coupling. Lower and upper limits at 95% confidence level are set at −1.3 and +8.0 times the Yukawa coupling strength in the Standard Model

    Operation and performance of the ATLAS semiconductor tracker

    Get PDF
    The semiconductor tracker is a silicon microstrip detector forming part of the inner tracking system of the ATLAS experiment at the LHC. The operation and performance of the semiconductor tracker during the first years of LHC running are described. More than 99% of the detector modules were operational during this period, with an average intrinsic hit efficiency of (99.74±0.04)%. The evolution of the noise occupancy is discussed, and measurements of the Lorentz angle, Ύ-ray production and energy loss presented. The alignment of the detector is found to be stable at the few-micron level over long periods of time. Radiation damage measurements, which include the evolution of detector leakage currents, are found to be consistent with predictions and are used in the verification of radiation background simulations

    Search for the Standard Model Higgs boson decay to ÎŒ+Ό− with the ATLAS detector

    Get PDF
    A search is reported for Higgs boson decay to ÎŒ+Ό−Ό+Ό− using data with an integrated luminosity of 24.8 fb−124.8 fb−Âč collected with the ATLAS detector in pp collisions at √s=7 and 8 TeV at the CERN Large Hadron Collider. The observed dimuon invariant mass distribution is consistent with the Standard Model background-only hypothesis in the 120–150 GeV search range. For a Higgs boson with a mass of 125.5 GeV, the observed (expected) upper limit at the 95% confidence level is 7.0 (7.2) times the Standard Model expectation. This corresponds to an upper limit on the branching ratio BR(H→Ό+Ό−)of 1.5×10−31.5×10−3

    Search for Wâ€Č→tb→qqbb decays in pp collisions at √s=8 TeV with the ATLAS detector

    Get PDF
    A search for a massive Wâ€Č gauge boson decaying to a top quark and a bottom quark is performed with the ATLAS detector in pp collisions at the LHC. The dataset was taken at a centre-of-mass energy of √s=8 TeV and corresponds to 20.3 fb−1 of integrated luminosity. This analysis is done in the hadronic decay mode of the top quark, where novel jet substructure techniques are used to identify jets from high-momentum top quarks. This allows for a search for high-mass Wâ€Č bosons in the range 1.5–3.0 TeV. b-tagging is used to identify jets originating from b-quarks. The data are consistent with Standard Model background-only expectations, and upper limits at 95 % confidence level are set on the Wâ€Č→tb cross section times branching ratio ranging from 0.16pb to 0.33pb for left-handed Wâ€Č bosons, and ranging from 0.10pb to 0.21pb for Wâ€Č bosons with purely right-handed couplings. Upper limits at 95 % confidence level are set on the Wâ€Č-boson coupling to tb as a function of the Wâ€Č mass using an effective field theory approach, which is independent of details of particular models predicting a Wâ€Čboson

    Fiducial and differential cross sections of Higgs boson production measured in the four-lepton decay channel in pp collisions at √s = 8 TeV with the ATLAS detector

    Get PDF
    Measurements of fiducial and differential cross sections of Higgs boson production in the H→ZZ∗ → 4ℓ decay channel are presented. The cross sections are determined within a fiducial phase space and corrected for detection efficiency and resolution effects. They are based on 20.3 fb−Âč of pp collision data, produced at √s = 8 TeV centre-of-mass energy at the LHC and recorded by the ATLAS detector. The differential measurements are performed in bins of transverse momentum and rapidity of the four-lepton system, the invariant mass of the subleading lepton pair and the decay angle of the leading lepton pair with respect to the beam line in the four-lepton rest frame, as well as the number of jets and the transverse momentum of the leading jet. The measured cross sections are compared to selected theoretical calculations of the Standard Model expectations. No significant deviation from any of the tested predictions is found
    • 

    corecore