32 research outputs found
Laparoscopic versus open splenectomy for nontraumatic diseases
BACKGROUND: Laparoscopic splenectomy (LS) is the standard procedure for normal size or moderately enlarged spleens; open splenectomy (OS) is preferred in cases of splenomegaly. In this study, indications for and complications of open and laparoscopic splenectomy were analyzed, with the aim to identify patients who will benefit from either technique. METHOD: A consecutive series of 52 patients undergoing elective open or laparoscopic splenectomy between January 2001 and December 2006 was analyzed. Spleen volume was calculated as length x width x depth from the pathologist's measurements. RESULTS: LS was performed in 25 patients with a median age of 41 years (range = 24-65). OS was performed in 27 patients with a median age of 60 years (range = 24-86) (p < 0.001). Conversion to OS was necessary in two patients (8%). Operation time was significantly shorter in LS (p < 0.05). Spleen volume was significantly greater in patients who underwent open (median = 2520 ml, range = 150-16,800 ml) versus laparoscopic (median = 648 ml, range = 150-4860 ml) splenectomy (p = 0.001). In 36% of all laparoscopic procedures, spleen volume exceeded 1000 ml. The underlying disease was mainly immunothrombocytopenia in LS patients and lymphoma and osteomyelofibrosis in OS patients. Five patients died after OS. Significantly more patients were hospitalized longer than 7 days following OS than following LS (p < 0.05). Overall complication rate was higher after OS (LS, 8; OS, 13 patients; p < 0.05). CONCLUSIONS: LS was preferred in younger patients with moderate splenomegaly, while massive splenomegaly mostly led to OS. In view of the absence of technique-related differences, LS can primarily be attempted in all patients
Patient Safety in the Cardiac Operating Room: Human Factors and Teamwork: A Scientific Study from the American Heart Association
The cardiac surgical operating room (OR) is a complex environment in which highly trained subspecialists interact with each other using sophisticated equipment to care for patients with severe cardiac disease and significant comorbidities. Thousands of patient lives have been saved or significantly improved with the advent of modern cardiac surgery. Indeed, both mortality and morbidity for coronary artery bypass surgery have decreased during the past decade. Nonetheless, the highly skilled and dedicated personnel in cardiac ORs are human and will make errors. Refined techniques, advanced technologies, and enhanced coordination of care have led to significant improvements in cardiac surgery outcomes
Multi-messenger observations of a binary neutron star merger
On 2017 August 17 a binary neutron star coalescence candidate (later designated GW170817) with merger time 12:41:04 UTC was observed through gravitational waves by the Advanced LIGO and Advanced Virgo detectors. The Fermi Gamma-ray Burst Monitor independently detected a gamma-ray burst (GRB 170817A) with a time delay of ~1.7 s with respect to the merger time. From the gravitational-wave signal, the source was initially localized to a sky region of 31 deg2 at a luminosity distance of 40+8-8 Mpc and with component masses consistent with neutron stars. The component masses were later measured to be in the range 0.86 to 2.26 Mo. An extensive observing campaign was launched across the electromagnetic spectrum leading to the discovery of a bright optical transient (SSS17a, now with the IAU identification of AT 2017gfo) in NGC 4993 (at ~40 Mpc) less than 11 hours after the merger by the One- Meter, Two Hemisphere (1M2H) team using the 1 m Swope Telescope. The optical transient was independently detected by multiple teams within an hour. Subsequent observations targeted the object and its environment. Early ultraviolet observations revealed a blue transient that faded within 48 hours. Optical and infrared observations showed a redward evolution over ~10 days. Following early non-detections, X-ray and radio emission were discovered at the transient’s position ~9 and ~16 days, respectively, after the merger. Both the X-ray and radio emission likely arise from a physical process that is distinct from the one that generates the UV/optical/near-infrared emission. No ultra-high-energy gamma-rays and no neutrino candidates consistent with the source were found in follow-up searches. These observations support the hypothesis that GW170817 was produced by the merger of two neutron stars in NGC4993 followed by a short gamma-ray burst (GRB 170817A) and a kilonova/macronova powered by the radioactive decay of r-process nuclei synthesized in the ejecta
A rare cause of CSF shunt "failure" in a patient with NPH
A rare cause of CSF shunt "failure" in a patient with NPH