69 research outputs found

    Human blood autoantibodies in the detection of colorectal cancer

    Get PDF
    Colorectal cancer (CRC) is the second most common malignancy in the western world. Early detection and diagnosis of all cancer types is vital to improved prognosis by enabling early treatment when tumours should be both resectable and curable. Sera from 3 different cohorts; 42 sera (21 CRC and 21 matched controls) from New York, USA, 200 sera from Pittsburgh, USA (100 CRC and 100 controls) and 20 sera from Dundee, UK (10 CRC and 10 controls) were tested against a panel of multiple tumour-associated antigens (TAAs) using an optimised multiplex microarray system. TAA specific IgG responses were interpo- lated against the internal IgG standard curve for each sample. Individual TAA specific responses were examined in each cohort to determine cutoffs for a robust initial scoring method to establish sensitivity and specificity. Sensitivity and specificity of combinations of TAAs provided good discrimination between cancer-positive and normal serum. The overall sensitivity and specificity of the sample sets tested against a panel of 32 TAAs were 61.1% and 80.9% respectively for 6 antigens; p53, AFP, K RAS, Annexin, RAF1 and NY-CO16. Furthermore, the observed sensitivity in Pittsburgh sample set in different clinical stages of CRC;stageI(n=19),stageII(n=40),stageIII(n=34)andstageIV(n=6)wassimilar (73.6%, 75.0%, 73.5% and 83.3%, respectively), with similar levels of sensitivity for right and left sided CRC. We identified an antigen panel of sufficient sensitivity and specificity for early detection of CRC, based upon serum profiling of autoantibody response using a robust multiplex antigen microarray technology. This opens the possibility of a blood test for screening and detection of early colorectal cancer. However this panel will require further validation studies before they can be proposed for clinical practice

    The postural effects of load carriage on young people – a systematic review

    Get PDF
    BACKGROUND: Spinal pain in young people is a significant source of morbidity in industrialised countries. The carriage of posterior loads by young people has been linked with spinal pain, and the amount of postural change produced by load carriage has been used as a measure of the potential to cause tissue damage. The purpose of this review was to identify, appraise and collate the research evidence regarding load-carriage related postural changes in young people. METHODS: A systematic literature review sought published literature on the postural effects of load carriage in young people. Sixteen databases were searched, which covered the domains of allied health, childcare, engineering, health, health-research, health-science, medicine and medical sciences. Two independent reviewers graded the papers according to Lloyd-Smith's hierarchy of evidence scale. Papers graded between 1a (meta-analysis of randomised controlled trials) and 2b (well-designed quasi-experimental study) were eligible for inclusion in this review. These papers were quality appraised using a modified Crombie tool. The results informed the collation of research evidence from the papers sourced. RESULTS: Seven papers were identified for inclusion in this review. Methodological differences limited our ability to collate evidence. CONCLUSIONS: Evidence based recommendations for load carriage in young people could not be made based on the results of this systematic review, therefore constraining the use of published literature to inform good load carriage practice for young people

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    C. albicans Colonization of Human Mucosal Surfaces

    Get PDF
    Background: Candida albicans is a low level commensal organism in normal human populations with the continuous potential to expand and cause a spectrum of clinical conditions. Methodology/Principal Findings: Using ex vivo human organ cultures and populations of primary human cells, we have developed several related experimental systems to examine early-stage interactions between C. albicans and mucosal surfaces. Experiments have been conducted both with exogenously added C. albicans and with overtly normal human mucosal surfaces supporting pre-existing infections with natural isolates of Candida. Under different culture conditions, we have demonstrated the formation of C. albicans colonies on human target cells and filament formation, equivalent to tissue invasion. Conclusions/Significance: These organ culture systems provide a valuable new resource to examine the molecular and cellular basis for Candida colonization of human mucosal surfaces

    The Frequency of Dust Lanes in Edge-on Spiral Galaxies Identified by Galaxy Zoo in KiDS Imaging of GAMA Targets

    Get PDF
    Dust lanes bisect the plane of a typical edge-on spiral galaxy as a dark optical absorption feature. Their appearance is linked to the gravitational stability of spiral disks; the fraction of edge-on galaxies that displays a dust lane is a direct indicator of the typical vertical balance between gravity and turbulence: a balance struck between the energy input from star formation and the gravitational pull into the plane of the disk. Based on morphological classifications by the Galaxy Zoo project on the Kilo Degree Survey (KiDS) imaging data in the Galaxy and Mass Assembly (GAMA) fields, we explore the relation of dust lanes to the galaxy characteristics, most of which were determined using the Magphys spectral energy distribution fitting tool: stellar mass, total and specific star formation rates, and several parameters describing the cold dust component. We find that the fraction of dust lanes does depend on the stellar mass of the galaxy; they start to appear at M* ~ 109 M ⊙. A dust lane also strongly implies a dust mass of at least 105 M ⊙, but otherwise does not correlate with cold dust mass parameters of the Magphys spectral energy distribution analysis, nor is there a link with the star formation rate, specific or total. Dust lane identification does not depend on disk ellipticity (disk thickness) or Sérsic profile but correlates with bulge morphology; a round bulge favors dust lane votes. The central component along the line of sight that produces the dust lane is not associated with either one of the components fit by Magphys, the cold diffuse component or the localized, heated component in H ii regions, but a mix of these two

    Sensory Input Pathways and Mechanisms in Swallowing: A Review

    Get PDF
    Over the past 20 years, research on the physiology of swallowing has confirmed that the oropharyngeal swallowing process can be modulated, both volitionally and in response to different sensory stimuli. In this review we identify what is known regarding the sensory pathways and mechanisms that are now thought to influence swallowing motor control and evoke its response. By synthesizing the current state of research evidence and knowledge, we identify continuing gaps in our knowledge of these mechanisms and pose questions for future research

    Aligning the CMS Muon Chambers with the Muon Alignment System during an Extended Cosmic Ray Run

    Get PDF
    Peer reviewe

    Canagliflozin and Renal Outcomes in Type 2 Diabetes and Nephropathy

    Get PDF
    BACKGROUND Type 2 diabetes mellitus is the leading cause of kidney failure worldwide, but few effective long-term treatments are available. In cardiovascular trials of inhibitors of sodium–glucose cotransporter 2 (SGLT2), exploratory results have suggested that such drugs may improve renal outcomes in patients with type 2 diabetes. METHODS In this double-blind, randomized trial, we assigned patients with type 2 diabetes and albuminuric chronic kidney disease to receive canagliflozin, an oral SGLT2 inhibitor, at a dose of 100 mg daily or placebo. All the patients had an estimated glomerular filtration rate (GFR) of 30 to 300 to 5000) and were treated with renin–angiotensin system blockade. The primary outcome was a composite of end-stage kidney disease (dialysis, transplantation, or a sustained estimated GFR of <15 ml per minute per 1.73 m 2), a doubling of the serum creatinine level, or death from renal or cardiovascular causes. Prespecified secondary outcomes were tested hierarchically. RESULTS The trial was stopped early after a planned interim analysis on the recommendation of the data and safety monitoring committee. At that time, 4401 patients had undergone randomization, with a median follow-up of 2.62 years. The relative risk of the primary outcome was 30% lower in the canagliflozin group than in the placebo group, with event rates of 43.2 and 61.2 per 1000 patient-years, respectively (hazard ratio, 0.70; 95% confidence interval [CI], 0.59 to 0.82; P=0.00001). The relative risk of the renal-specific composite of end-stage kidney disease, a doubling of the creatinine level, or death from renal causes was lower by 34% (hazard ratio, 0.66; 95% CI, 0.53 to 0.81; P<0.001), and the relative risk of end-stage kidney disease was lower by 32% (hazard ratio, 0.68; 95% CI, 0.54 to 0.86; P=0.002). The canagliflozin group also had a lower risk of cardiovascular death, myocardial infarction, or stroke (hazard ratio, 0.80; 95% CI, 0.67 to 0.95; P=0.01) and hospitalization for heart failure (hazard ratio, 0.61; 95% CI, 0.47 to 0.80; P<0.001). There were no significant differences in rates of amputation or fracture. CONCLUSIONS In patients with type 2 diabetes and kidney disease, the risk of kidney failure and cardiovascular events was lower in the canagliflozin group than in the placebo group at a median follow-up of 2.62 years

    Mobile Applications and Wearables for Chronic Respiratory Disease Monitoring

    Get PDF
    Mobile health (mHealth) has tremendous potential to benefit patients, providers, and the entire healthcare system. Benefits for patients to adopt mHealth include more effective access to health providers, reduced costs of care, and better health control. For physicians and the healthcare system, reasons to embrace mHealth are enhanced health outcomes, facilitated access to patients for care, and decreased time required for administrative tasks. Currently, some mobile apps and wearables dedicated to respiratory health provide medical education and messaging services, enable diary logs, aid with disease self-management, and include educational games. Major challenges for mHealth to be widely adopted include lack of studies demonstrating effectiveness, limited access to technology by all patients, decreased adoption over time, high costs, and data privacy concerns
    • …
    corecore