37 research outputs found

    Comment

    Get PDF
    A chloride-based chemical-vapor-deposition (CVD) process has been successfully used to grow very high quality 3C-SiC epitaxial layers on on-axis α-SiC substrates. An accurate process parameters study was performed testing the effect of temperature, surface preparation, precursor ratios, nitrogen addition, and substrate polytype and polarity. The 3C layers deposited showed to be largely single-domain material of very high purity and of excellent electrical characteristics. A growth rate of up to 10 μm/h and a low background doping enable deposition of epitaxial layers suitable for MOSFET devices

    Wide-range resistivity characterization of semiconductors with terahertz time-domain spectroscopy

    Full text link
    Resistivity is one of the most important characteristics in the semiconductor industry. The most common way to measure resistivity is the four-point probe method, which requires physical contact with the material under test. Terahertz time domain spectroscopy, a fast and non-destructive measurement method, is already well established in the characterization of dielectrics. In this work, we demonstrate the potential of two Drude model-based approaches to extract resistivity values from terahertz time-domain spectroscopy measurements of silicon in a wide range from about 103^{-3} Ω\Omegacm to 102^{2} Ω\Omegacm. One method is an analytical approach and the other is an optimization approach. Four-point probe measurements are used as a reference. In addition, the spatial resistivity distribution is imaged by X-Y scanning of the samples to detect inhomogeneities in the doping distribution

    Preoperative Imaging with [F-18]-Fluorocholine PET/CT in Primary Hyperparathyroidism

    Get PDF
    Primary hyperparathyroidism (pHPT) is a common endocrine disorder due to hyperfunctioning parathyroid glands. To date, the only curing therapy is surgical removal of the dysfunctional gland, making correct detection and localization crucial in order to perform a minimally invasive parathyroidectomy. F-18-Fluorocholine positron emission tomography/computed tomography (F-18-FCH PET/CT) has shown promising results for the detection of pHPT, suggesting superiority over conventional imaging with ultrasounds or scintigraphy. A total of 33 patients with pHPT who had negative or equivocal findings in conventional imaging received F-18-FCH PET/CT preoperatively and were retrospectively included. A pathological hyperfunctional parathyroid gland was diagnosed in 24 cases (positive PET, 72.7%), 4 cases showed equivocal choline uptake (equivocal PET, 12.1%), and in 5 cases, no enhanced choline uptake was evident (negative PET, 15.2%). Twelve of the twenty-four detected adenoma patients underwent surgery, and in all cases, a pathological parathyroid adenoma was resected at the site detected by PET/CT. Two of the six patients without pathological choline uptake who received a parathyroidectomy revealed no evidence of parathyroid adenoma tissue in the histopathological evaluation. This retrospective study analyzes F-18-FCH PET/CT in a challenging patient cohort with pHPT and negative or equivocal conventional imaging results and supports the use of F-18-FCH for the diagnosis of hyperfunctional parathyroid tissue, especially in this patient setting, with a 100% true positive and true negative detection rate. Our study further demonstrates the importance of F-18-FCH PET/CT for successful surgical guidance

    68Ga-EMP-100 PET/CT-a novel ligand for visualizing c-MET expression in metastatic renal cell carcinoma-first in-human biodistribution and imaging results

    Get PDF
    BACKGROUND 68Ga-EMP-100 is a novel positron emission tomography (PET) ligand that directly targets tumoral c-MET expression. Upregulation of the receptor tyrosin kinase c-MET in renal cell carcinoma (RCC) is correlated with overall survival in metastatic disease (mRCC). Clinicopathological staging of c-MET expression could improve patient management prior to systemic therapy with for instance inhibitors targeting c-MET such as cabozantinib. We present the first in-human data of 68Ga-EMP-100 in mRCC patients evaluating uptake characteristics in metastases and primary RCC. METHODS Twelve patients with mRCC prior to anticipated cabozantinib therapy underwent 68Ga-EMP-100 PET/CT imaging. We compared the biodistribution in normal organs and tumor uptake of mRCC lesions by standard uptake value (SUVmean) and SUVmax measurements. Additionally, metastatic sites on PET were compared to contrast-enhanced computed tomography (CT) and the respective, quantitative PET parameters were assessed and then compared inter- and intra-individually. RESULTS Overall, 87 tumor lesions were analyzed. Of these, 68/87 (79.3%) were visually rated c-MET-positive comprising a median SUVmax of 4.35 and SUVmean of 2.52. Comparing different tumor sites, the highest uptake intensity was found in tumor burden at the primary site (SUVmax 9.05 (4.86-29.16)), followed by bone metastases (SUVmax 5.56 (0.97-15.85)), and lymph node metastases (SUVmax 3.90 (2.13-6.28)) and visceral metastases (SUVmax 3.82 (0.11-16.18)). The occurrence of visually PET-negative lesions (20.7%) was distributed heterogeneously on an intra- and inter-individual level; the largest proportion of PET-negative metastatic lesions were lung and liver metastases. The highest physiological 68Ga-EMP-100 accumulation besides the urinary bladder content was seen in the kidneys, followed by moderate uptake in the liver and the spleen, whereas significantly lower uptake intensity was observed in the pancreas and the intestines. CONCLUSION Targeting c-MET expression, 68Ga-EMP-100 shows distinctly elevated uptake in mRCC patients with partially high inter- and intra-individual differences comprising both c-MET-positive and c-MET-negative lesions. Our first clinical results warrant further systemic studies investigating the clinical use of 68Ga-EMP-100 as a biomarker in mRCC patients

    The genetic architecture of the human cerebral cortex

    Get PDF
    The cerebral cortex underlies our complex cognitive capabilities, yet little is known about the specific genetic loci that influence human cortical structure. To identify genetic variants that affect cortical structure, we conducted a genome-wide association meta-analysis of brain magnetic resonance imaging data from 51,665 individuals. We analyzed the surface area and average thickness of the whole cortex and 34 regions with known functional specializations. We identified 199 significant loci and found significant enrichment for loci influencing total surface area within regulatory elements that are active during prenatal cortical development, supporting the radial unit hypothesis. Loci that affect regional surface area cluster near genes in Wnt signaling pathways, which influence progenitor expansion and areal identity. Variation in cortical structure is genetically correlated with cognitive function, Parkinson's disease, insomnia, depression, neuroticism, and attention deficit hyperactivity disorder

    Search for dark matter produced in association with bottom or top quarks in √s = 13 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for weakly interacting massive particle dark matter produced in association with bottom or top quarks is presented. Final states containing third-generation quarks and miss- ing transverse momentum are considered. The analysis uses 36.1 fb−1 of proton–proton collision data recorded by the ATLAS experiment at √s = 13 TeV in 2015 and 2016. No significant excess of events above the estimated backgrounds is observed. The results are in- terpreted in the framework of simplified models of spin-0 dark-matter mediators. For colour- neutral spin-0 mediators produced in association with top quarks and decaying into a pair of dark-matter particles, mediator masses below 50 GeV are excluded assuming a dark-matter candidate mass of 1 GeV and unitary couplings. For scalar and pseudoscalar mediators produced in association with bottom quarks, the search sets limits on the production cross- section of 300 times the predicted rate for mediators with masses between 10 and 50 GeV and assuming a dark-matter mass of 1 GeV and unitary coupling. Constraints on colour- charged scalar simplified models are also presented. Assuming a dark-matter particle mass of 35 GeV, mediator particles with mass below 1.1 TeV are excluded for couplings yielding a dark-matter relic density consistent with measurements
    corecore