123 research outputs found

    Coherence length of an elongated condensate: a study by matter-wave interferometry

    Full text link
    We measure the spatial correlation function of Bose-Einstein condensates in the cross-over region between phase-coherent and strongly phase-fluctuating condensates. We observe the continuous path from a gaussian-like shape to an exponential-like shape characteristic of one-dimensional phase-fluctuations. The width of the spatial correlation function as a function of the temperature shows that the condensate coherence length undergoes no sharp transition between these two regimes.Comment: 8 pages, 6 figure, submitted to EPJ

    86-km optical link with a resolution of 2.10-18 for RF frequency transfer

    Full text link
    RF frequency transfer over an urban 86 km fibre has been demonstrated with a resolution of 2.10-18 at one day measuring time using an optical compensator. This result is obtained with a reference carrier frequency of 1 GHz, and a rapid scrambling of the polarisation state of the input light in order to reduce the sensitivity to the polarisation mode dispersion in the fibre. The limitation due to the fibre chromatic dispersion associated with the laser frequency fluctuations is highlighted and analyzed. A preliminary test of an extended compensated link over 186 km using optical amplifiers gives a resolution below 10-17 at 1 day

    Measurement of the LT-asymmetry in \pi^0 electroproduction at the energy of the \Delta (1232) resonance

    Full text link
    The reaction p(e,e'p)pi^0 has been studied at Q^2=0.2 (GeV/c)^2 in the region of W=1232 MeV. From measurements left and right of q, cross section asymmetries \rho_LT have been obtained in forward kinematics \rho_LT(\theta_\pi^0=20deg) = (-11.68 +/- 2.36_stat +/- 2.36_sys)$ and backward kinematics \rho_LT(\theta_\pi^0=160deg) =(12.18 +/- 0.27_stat +/- 0.82_sys). Multipole ratios \Re(S_1+^* M_1+)/|M_1+|^2 and \Re(S_0+^* M_1+)/|M_1+|^2 were determined in the framework of the MAID2003 model. The results are in agreement with older data. The unusally strong negative \Re(S_0+^* M_1+)/|M_1+|^2 required to bring also the result of Kalleicher et al. in accordance with the rest of the data is almost excluded.Comment: 7 pages, 7 figures, 4 tables. Changed content. Accepted for publication in EPJ

    Triangulations and Severi varieties

    Full text link
    We consider the problem of constructing triangulations of projective planes over Hurwitz algebras with minimal numbers of vertices. We observe that the numbers of faces of each dimension must be equal to the dimensions of certain representations of the automorphism groups of the corresponding Severi varieties. We construct a complex involving these representations, which should be considered as a geometric version of the (putative) triangulations

    Amicable pairs and aliquot cycles for elliptic curves

    Full text link
    An amicable pair for an elliptic curve E/Q is a pair of primes (p,q) of good reduction for E satisfying #E(F_p) = q and #E(F_q) = p. In this paper we study elliptic amicable pairs and analogously defined longer elliptic aliquot cycles. We show that there exist elliptic curves with arbitrarily long aliqout cycles, but that CM elliptic curves (with j not 0) have no aliqout cycles of length greater than two. We give conjectural formulas for the frequency of amicable pairs. For CM curves, the derivation of precise conjectural formulas involves a detailed analysis of the values of the Grossencharacter evaluated at a prime ideal P in End(E) having the property that #E(F_P) is prime. This is especially intricate for the family of curves with j = 0.Comment: 53 page

    Elliptic flow of charged particles in Pb-Pb collisions at 2.76 TeV

    Get PDF
    We report the first measurement of charged particle elliptic flow in Pb-Pb collisions at 2.76 TeV with the ALICE detector at the CERN Large Hadron Collider. The measurement is performed in the central pseudorapidity region (|η\eta|<0.8) and transverse momentum range 0.2< pTp_{\rm T}< 5.0 GeV/cc. The elliptic flow signal v2_2, measured using the 4-particle correlation method, averaged over transverse momentum and pseudorapidity is 0.087 ±\pm 0.002 (stat) ±\pm 0.004 (syst) in the 40-50% centrality class. The differential elliptic flow v2(pT)_2(p_{\rm T}) reaches a maximum of 0.2 near pTp_{\rm T} = 3 GeV/cc. Compared to RHIC Au-Au collisions at 200 GeV, the elliptic flow increases by about 30%. Some hydrodynamic model predictions which include viscous corrections are in agreement with the observed increase.Comment: 10 pages, 4 captioned figures, published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/389

    Planck intermediate results X : Physics of the hot gas in the Coma cluster

    Get PDF
    Peer reviewe

    Planck Intermediate Results II: Comparison of Sunyaev–Zeldovich measurements from Planck and from the Arcminute Microkelvin Imager for 11 galaxy clusters

    Get PDF
    A comparison is presented of Sunyaev–Zeldovich measurements for 11 galaxy clusters as obtained by Planck and by the ground-based interferom- eter, the Arcminute Microkelvin Imager. Assuming a universal spherically-symmetric Generalised Navarro, Frenk & White (GNFW) model for the cluster gas pressure profile, we jointly constrain the integrated Compton-Y parameter (Y500) and the scale radius (ξ500) of each cluster. Our resulting constraints in the Y500 − ξ500 2D parameter space derived from the two instruments overlap significantly for eight of the clusters, although, overall, there is a tendency for AMI to find the Sunyaev–Zeldovich signal to be smaller in angular size and fainter than Planck. Significant discrepancies exist for the three remaining clusters in the sample, namely A1413, A1914, and the newly-discovered Planck cluster PLCKESZ G139.59+24.18. The robustness of the analysis of both the Planck and AMI data is demonstrated through the use of detailed simulations, which also discount confusion from residual point (radio) sources and from diffuse astrophysical foregrounds as possible explanations for the discrepancies found. For a subset of our cluster sample, we have investigated the dependence of our results on the assumed pressure profile by repeating the analysis adopting the best-fitting GNFW profile shape which best matches X-ray observations. Adopting the best-fitting profile shape from the X-ray data does not, in general, resolve the discrepancies found in this subset of five clusters. Though based on a small sample, our results suggest that the adopted GNFW model may not be sufficiently flexible to describe clusters universally

    Planck intermediate results I : Further validation of new Planck clusters with XMM-Newton

    Get PDF
    Peer reviewe
    • 

    corecore