Right Porto-Ovarian H-Shunt for the Surgical Treatment of Symptomatic Portal Biliopathy: A Case Report and Literature Review
Portal hypertension, especially when it is caused by extrahepatic portal vein thrombosis, is commonly followed by the development of an abnormal periportal and pericholedochal variceal network, which form a portal cavernoma. This may exert extrinsic pressure on the adjacent biliary ducts and gallblader, causing morphologic abnormalities, termed portal biliopathy, which is usually leading to asymptomatic cholestasis, while less frequently it can be associated with obstructive jaundice, gallstone formation, and cholangitis. Endoscopic stone extraction can effectively treat portal biliopathy when cholangitis is associated with common bile duct stones. Portosystemic shunts are indicated in cases of disease recurrence as they can achieve regression of portal cavernoma and usually relieve symptomatic portal biliopathy. This case describes an alternative partial portosystemic shunt that utilizes the right ovarian vein as an autologous conduit for the surgical treatment of symptomatic portal biliopathy
Consensus care recommendations for alfapump® in cirrhotic patients with refractory or recurrent ascites
BACKGROUND: The alfapump® is an implantable class III medical device that pumps ascitic fluid from the peritoneal space to the urinary bladder from where it is excreted. The pump reduces or abrogates the need for repeated paracentesis in patients with recurrent or refractory ascites. AIMS: To improve outcomes for alfapump® implantation and pre- and post-implant patient management in both clinical trial and real-world settings by development of consensus recommendations. METHODS: The alfapump® working group consisting of hepatologists and surgeons with extensive experience in implantation of the alfapump® and patient management met on two occasions: (1) to determine the key areas where recommendations should be made; and (2) to discuss the experiences of the working group within those areas and formulate draft statements. Developed statements were submitted to the group and consensus sought on relevance and wording through a collaborative iterative approach in order to consolidate the recommendations into consensus statements. Only recommendations agreed upon unanimously were included. RESULTS: Twenty-three consensus recommendations were developed in the areas of pre-implantation procedure, (three statements), surgical implant procedure (11 statements), immediate post-implant care (three statements) and long-term management (six statements). CONCLUSIONS: The consensus statements are a valuable reference resource for physicians managing patients with the alfapump® and for those considering management strategies for patients with refractory ascites
Consensus care recommendations for alfapump® in cirrhotic patients with refractory or recurrent ascites.
BACKGROUND
The alfapump® is an implantable class III medical device that pumps ascitic fluid from the peritoneal space to the urinary bladder from where it is excreted. The pump reduces or abrogates the need for repeated paracentesis in patients with recurrent or refractory ascites.
AIMS
To improve outcomes for alfapump® implantation and pre- and post-implant patient management in both clinical trial and real-world settings by development of consensus recommendations.
METHODS
The alfapump® working group consisting of hepatologists and surgeons with extensive experience in implantation of the alfapump® and patient management met on two occasions: (1) to determine the key areas where recommendations should be made; and (2) to discuss the experiences of the working group within those areas and formulate draft statements. Developed statements were submitted to the group and consensus sought on relevance and wording through a collaborative iterative approach in order to consolidate the recommendations into consensus statements. Only recommendations agreed upon unanimously were included.
RESULTS
Twenty-three consensus recommendations were developed in the areas of pre-implantation procedure, (three statements), surgical implant procedure (11 statements), immediate post-implant care (three statements) and long-term management (six statements).
CONCLUSIONS
The consensus statements are a valuable reference resource for physicians managing patients with the alfapump® and for those considering management strategies for patients with refractory ascites
Measurement of real-time tissue elastography in a phantom model and comparison with transient elastography in pediatric patients with liver diseases
PURPOSEWe aimed to determine the comparability of real-time tissue elastography (RTE) and transient elastography (TE) in pediatric patients with liver diseases. MATERIALS AND METHODSRTE was performed on the Elasticity QA Phantom Model 049 (Computerized Imaging Reference Systems Company Inc., Norfolk, Virginia, USA), which has five areas with different levels of stiffness. RTE measurements of relative stiffness (MEAN [mean value of tissue elasticity], AREA [% of blue color-coded stiffer tissue]) in the phantom were compared with the phantom stiffness specified in kPa (measurement unit of TE). RTE and TE were performed on 147 pediatric patients with various liver diseases. A total of 109 measurements were valid. The participants had following diseases: metabolic liver disease (n=25), cystic fibrosis (n=20), hepatopathy of unknown origin (n=11), autoimmune hepatitis (n=12), Wilson’s disease (n=11), and various liver parenchyma alterations (n=30). Correlations between RTE and TE measurements in the patients were calculated. In addition, RTE was performed on a control group (n=30), and the RTE values between the patient and control groups were compared. RESULTSThe RTE parameters showed good correlation in the phantom model with phantom stiffness (MEAN/kPa, r=-0.97; AREA/kPa, r=0.98). However, the correlation of RTE and TE was weak in the patient group (MEAN/kPa, r=-0.23; AREA/kPa, r=0.24). A significant difference was observed between the patient and control groups (MEAN, P = 5.32 e-7; AREA, P = 1.62 e-6). CONCLUSIONIn the phantom model, RTE was correlated with kPa, confirming the presumed comparability of the methods. However, there was no direct correlation between RTE and TE in patients with defined liver diseases under real clinical conditions
Feeding Kinematics, Suction, and Hydraulic Jetting Performance of Harbor Seals (Phoca vitulina)
The feeding kinematics, suction and hydraulic jetting capabilities of captive harbor seals (Phoca vitulina) were characterized during controlled feeding trials. Feeding trials were conducted using a feeding apparatus that allowed a choice between biting and suction, but also presented food that could be ingested only by suction. Subambient pressure exerted during suction feeding behaviors was directly measured using pressure transducers. The mean feeding cycle duration for suction-feeding events was significantly shorter (0.15±0.09 s; P<0.01) than biting feeding events (0.18±0.08 s). Subjects feeding in-water used both a suction and a biting feeding mode. Suction was the favored feeding mode (84% of all feeding events) compared to biting, but biting comprised 16% of feeding events. In addition, seals occasionally alternated suction with hydraulic jetting, or used hydraulic jetting independently, to remove fish from the apparatus. Suction and biting feeding modes were kinematically distinct regardless of feeding location (in-water vs. on-land). Suction was characterized by a significantly smaller gape (1.3±0.23 cm; P<0.001) and gape angle (12.9±2.02°), pursing of the rostral lips to form a circular aperture, and pursing of the lateral lips to occlude lateral gape. Biting was characterized by a large gape (3.63±0.21 cm) and gape angle (28.8±1.80°; P<0.001) and lip curling to expose teeth. The maximum subambient pressure recorded was 48.8 kPa. In addition, harbor seals were able to jet water at food items using suprambient pressure, also known as hydraulic jetting. The maximum hydraulic jetting force recorded was 53.9 kPa. Suction and hydraulic jetting where employed 90.5% and 9.5%, respectively, during underwater feeding events. Harbor seals displayed a wide repertoire of behaviorally flexible feeding strategies to ingest fish from the feeding apparatus. Such flexibility of feeding strategies and biomechanics likely forms the basis of their opportunistic, generalized feeding ecology and concomitant breadth of diet
Treatment of refractory ascites with an automated low-flow ascites pump in patients with cirrhosis.
BACKGROUND
Refractory ascites (RA) is a frequent complication of cirrhosis, requiring large volume paracentesis or placement of a transjugular intrahepatic portosystemic shunt (TIPSS). The automated low-flow ascites pump (alfapump, Sequana Medical AG, Zurich, Switzerland) is an innovative treatment option for patients with RA.
AIM
To assess safety and efficacy of this treatment in patients with a contraindication to TIPSS.
METHODS
Fifty-six patients (43 males; mean age 62 years) from centres in Germany, Switzerland, UK and Spain were included and followed for up to 24 months. Complications, device deficiencies, paracentesis frequency and patient survival were recorded.
RESULTS
At the time of this analysis, 3 patients completed the 24-month observation period, monitoring of 3 was ongoing, 9 underwent liver transplantation, 17 patients were withdrawn due to serious adverse events and 23 patients died. Most frequently observed technical complication was blocking of the peritoneal catheter. Twenty-three pump-related reinterventions (17 patients) and 12 pump exchanges (11 patients) were required during follow-up. The pump system was explanted in 48% of patients (in 17 patients due to serious adverse events, in 9 at the time of liver transplantation and in 1 due to recovery from RA). Median frequency of paracentesis dropped from 2.17 to 0.17 per month.
CONCLUSIONS
The alfapump can expand therapeutic options for cirrhotic patients with RA. Continuous drainage of ascites in a closed loop automated system led to significant reduction in paracentesis frequency. Technical and procedural improvements are required to reduce the rate of adverse events and reinterventions. https://clinicaltrials.gov/ct2/show/NCT01532427
Measurement of the cross-section of high transverse momentum vector bosons reconstructed as single jets and studies of jet substructure in pp collisions at √s = 7 TeV with the ATLAS detector
This paper presents a measurement of the cross-section for high transverse momentum W and Z bosons produced in pp collisions and decaying to all-hadronic final states. The data used in the analysis were recorded by the ATLAS detector at the CERN Large Hadron Collider at a centre-of-mass energy of √s = 7 TeV;{\rm Te}{\rm V}4.6\;{\rm f}{{{\rm b}}^{-1}}{{p}_{{\rm T}}}\gt 320\;{\rm Ge}{\rm V}|\eta |\lt 1.9{{\sigma }_{W+Z}}=8.5\pm 1.7$ pb and is compared to next-to-leading-order calculations. The selected events are further used to study jet grooming techniques
Observation of associated near-side and away-side long-range correlations in √sNN=5.02 TeV proton-lead collisions with the ATLAS detector
Two-particle correlations in relative azimuthal angle (Δϕ) and pseudorapidity (Δη) are measured in √sNN=5.02 TeV p+Pb collisions using the ATLAS detector at the LHC. The measurements are performed using approximately 1 μb-1 of data as a function of transverse momentum (pT) and the transverse energy (ΣETPb) summed over 3.1<η<4.9 in the direction of the Pb beam. The correlation function, constructed from charged particles, exhibits a long-range (2<|Δη|<5) “near-side” (Δϕ∼0) correlation that grows rapidly with increasing ΣETPb. A long-range “away-side” (Δϕ∼π) correlation, obtained by subtracting the expected contributions from recoiling dijets and other sources estimated using events with small ΣETPb, is found to match the near-side correlation in magnitude, shape (in Δη and Δϕ) and ΣETPb dependence. The resultant Δϕ correlation is approximately symmetric about π/2, and is consistent with a dominant cos2Δϕ modulation for all ΣETPb ranges and particle pT
Measurement of the production of a W boson in association with a charm quark in pp collisions at √s = 7 TeV with the ATLAS detector
The production of a W boson in association with a single charm quark is studied using 4.6 fb−1 of pp collision data at s√ = 7 TeV collected with the ATLAS detector at the Large Hadron Collider. In events in which a W boson decays to an electron or muon, the charm quark is tagged either by its semileptonic decay to a muon or by the presence of a charmed meson. The integrated and differential cross sections as a function of the pseudorapidity of the lepton from the W-boson decay are measured. Results are compared to the predictions of next-to-leading-order QCD calculations obtained from various parton distribution function parameterisations. The ratio of the strange-to-down sea-quark distributions is determined to be 0.96+0.26−0.30 at Q 2 = 1.9 GeV2, which supports the hypothesis of an SU(3)-symmetric composition of the light-quark sea. Additionally, the cross-section ratio σ(W + +c¯¯)/σ(W − + c) is compared to the predictions obtained using parton distribution function parameterisations with different assumptions about the s−s¯¯¯ quark asymmetry
Evidence for the Higgs-boson Yukawa coupling to tau leptons with the ATLAS detector
Results of a search for H → τ τ decays are presented, based on the full set of proton-proton collision data recorded by the ATLAS experiment at the LHC during 2011 and 2012. The data correspond to integrated luminosities of 4.5 fb−1 and 20.3 fb−1 at centre-of-mass energies of √s = 7 TeV and √s = 8 TeV respectively. All combinations of leptonic (τ → `νν¯ with ` = e, µ) and hadronic (τ → hadrons ν) tau decays are considered. An excess of events over the expected background from other Standard Model processes is found with an observed (expected) significance of 4.5 (3.4) standard deviations. This excess provides evidence for the direct coupling of the recently discovered Higgs boson to fermions. The measured signal strength, normalised to the Standard Model expectation, of µ = 1.43 +0.43 −0.37 is consistent with the predicted Yukawa coupling strength in the Standard Model
- …