245 research outputs found

    Mix design considerations of foamed bitumen mixtures with reclaimed asphalt pavement material

    Get PDF
    In the present work, a mix design parametric study was carried out with the aim of proposing a practical and consistent mix design procedure for foamed bitumen mixtures (FBMs). The mix design parameters that were adopted in the study are mixing and compaction water content (MWC), compaction effort using a gyratory compactor and aggregate temperature. This parametric study was initially carried out on FBMs with virgin limestone aggregate without reclaimed asphalt pavement (RAP) material and a mix design procedure was proposed. This proposed methodology was also found to apply to FBMs with RAP. A detailed consideration was also given to characterising the RAP material so as to understand its contribution to the mechanical properties of FBMs. Optimum MWC was achieved by optimising mechanical properties such as indirect tensile stiffness modulus and indirect tensile strength (ITS-dry and ITS-wet). A rational range of 75–85% of optimum water content obtained by the modified Proctor test was found to be the optimum range of MWC that gives optimum mechanical properties for FBMs. It was also found that the presence of RAP influenced the design foamed bitumen content, which means that treating RAP as black rock in FBM mix design is not appropriate. To study the influence of bitumen and water during compaction, modified Proctor compaction and gyratory compaction were employed on mixes with varying amounts of water and bitumen. By this, the work also evaluated the validity of the total fluid (water + bitumen) concept that is widely used in bitumen–emulsion-treated mixes, and found it not to be applicable

    Teleaudiology services for rehabilitation with hearing aids in adults: a systematic review

    Get PDF
    PURPOSE : This review examined (a) the current evidence from studies on teleaudiology applications for rehabilitation of adults with hearing impairment with hearing aids and (b) whether it is sufficient to support the translation into routine clinical practice. METHOD : A search strategy and eligibility criteria were utilized to include articles specifically related to hearing aid fitting and follow-up procedures that are involved in consultations for the rehabilitation of adults, where the service was provided by the clinician by teleaudiology. A search using key words and Medical Subject Headings (MeSH) was conducted on the main electronic databases that index health-related studies. The included studies were assessed using validated evaluation tools for methodological quality, level of evidence, and grade recommendations for application into practice. RESULTS : Fourteen studies were identified as being within the scope of this review. The evaluation tools showed that none of these studies demonstrated either a strong methodological quality or high level of evidence. Analysis of evidence identified 19 activities, which were classified into service outcomes categories of feasibility, barriers, efficiency, quality, and effectiveness. Recommendations could be made regarding the (a) feasibility, (b) barriers, and (c) efficiency of teleaudiology for the rehabilitation of hearing loss with hearing aids. CONCLUSION : This review provides up-to-date evidence for teleaudiology hearing aid services in new and experienced hearing aid users in different practice settings. Findings direct future research priorities to strengthen evidence-based practice. There is a need for further studies of many aspects of teleaudiology services for rehabilitation with hearing aids to support their implementation into clinical practice.CAPES Foundation, Process BEX 13410/13-0, Science Without Borders Program, Brazil (awarded to Karina F. M. Tao) and by Ear Science Institute Australia, Perth, Australia.http://jslhr.pubs.asha.orghj2018Speech-Language Pathology and Audiolog

    Clinician-rated quality of video otoscopy recordings and still images for the asynchronous assessment of middle-ear disease

    Get PDF
    INTRODUCTION : Video otoscopy plays an important role in improving access to ear health services. This study investigated the clinician-rated quality of video otoscopy recordings and still images, and compared their suitability for asynchronous diagnosis of middle-ear disease. METHODS : Two hundred and eighty video otoscopy image–recording pairs were collected from 150 children (aged six months to 15 years) by an ear, nose, and throat (ENT) specialist, audiologists, and trained research assistants, and independently rated by an audiologist and ENT surgeon. On a five-point scale, clinicians rated the cerumen amount, field of view, quality, focus, light, and gave an overall rating, and asked whether they could make an accurate diagnosis for both still images and recordings. RESULTS : More video otoscopy recordings were rated as ‘good’ or ‘excellent’ compared to still images across all domains. The mean difference between the two otoscopic procedures ratings was significant across almost all domains (p < 0.05), except ‘cerumen amount’. The suitability to make a diagnosis significantly improved when using recordings (p<0.05). Younger participant age was found to have a significant, negative impact on the ratings across all domains (p < 0.03). The role of the tester conducting video otoscopy did not have a significant impact on the ratings. DISCUSSION : Video otoscopy recordings were found to provide clearer views of the tympanic membrane and increase the ability to make diagnoses, compared to still images, for both audiologists and ENT surgeons. Research assistants with limited practice were able to obtain video otoscopy images and recordings that were comparable to the ones obtained by clinicians.The Telethon Kids Institutehttps://journals.sagepub.com/home/jtthj2022Speech-Language Pathology and Audiolog

    Clinician-rated quality of video otoscopy recordings and still images for the asynchronous assessment of middle-ear disease

    Get PDF
    INTRODUCTION : Video otoscopy plays an important role in improving access to ear health services. This study investigated the clinician-rated quality of video otoscopy recordings and still images, and compared their suitability for asynchronous diagnosis of middle-ear disease. METHODS : Two hundred and eighty video otoscopy image–recording pairs were collected from 150 children (aged six months to 15 years) by an ear, nose, and throat (ENT) specialist, audiologists, and trained research assistants, and independently rated by an audiologist and ENT surgeon. On a five-point scale, clinicians rated the cerumen amount, field of view, quality, focus, light, and gave an overall rating, and asked whether they could make an accurate diagnosis for both still images and recordings. RESULTS : More video otoscopy recordings were rated as ‘good’ or ‘excellent’ compared to still images across all domains. The mean difference between the two otoscopic procedures ratings was significant across almost all domains (p < 0.05), except ‘cerumen amount’. The suitability to make a diagnosis significantly improved when using recordings (p<0.05). Younger participant age was found to have a significant, negative impact on the ratings across all domains (p < 0.03). The role of the tester conducting video otoscopy did not have a significant impact on the ratings. DISCUSSION : Video otoscopy recordings were found to provide clearer views of the tympanic membrane and increase the ability to make diagnoses, compared to still images, for both audiologists and ENT surgeons. Research assistants with limited practice were able to obtain video otoscopy images and recordings that were comparable to the ones obtained by clinicians.The Telethon Kids Institutehttps://journals.sagepub.com/home/jtthj2022Speech-Language Pathology and Audiolog

    Dietary nitrate supplementation increases fractional exhaled nitric oxide: implications for the assessment of airway health in athletes

    Get PDF
    Background: Fractional exhaled nitric oxide (FeNO) is a simple tool that has an established role in the assessment of airway inflammation in athletes. Specifically, FeNO provides information concerning asthma phenotypes, aetiology of respiratory symptoms, response to anti-inflammatory agents, course of disease and adherence to medication. It is recognised that FeNO can be influenced by a variety of external factors (e.g. atopic status, exercise, respiratory tract infection), however, there remains limited research concerning the impact of dietary nitrate ingestion. The primary aim of this study was therefore to evaluate the effect of acute dietary nitrate supplementation on FeNO and resting pulmonary function parameters. Method: The study was conducted as a randomised double-blind placebo-controlled trial. Thirty male endurance trained athletes (age: 28 ± 6 yrs; BMI: 23 ± 2 kg.m-2) free from cardio-respiratory and metabolic disease, and stable at time of study entry (i.e. entirely asymptomatic without recent respiratory tract infection) attended the laboratory on two separate occasions. On arrival to the laboratory, athletes consumed either 140ml nitrate-rich beetroot juice (15.2 mmol nitrate) (NIT) or nitrate-depleted beetroot juice (0 mmol nitrate) (PLA). In accordance with international guidelines all athletes performed resting FeNO and forced spirometry (2.5hrs post ingestion). Airway inflammation was evaluated using established FeNO thresholds: (intermediate [≄25ppb] and high [>50ppb]). Results: All athletes demonstrated normal baseline lung function (FEV1 % predicted >80%). A three-fold rise in resting FeNO was observed following NIT (median [IQR]): 32ppb [37] in comparison to PLA: 10ppb [12] (P0.05). Conclusion: Dietary nitrate ingestion should be considered when employing FeNO for the assessment of airway health in athletes. Our findings have implications concerning the decision to initiate or modify inhaler therapy. Further research is therefore required to determine the impact of chronic dietary nitrat

    Characterization of covalent inhibitors that disrupt the interaction between the tandem SH2 domains of SYK and FCER1G phospho-ITAM

    Get PDF
    RNA sequencing and genetic data support spleen tyrosine kinase (SYK) and high affinity immunoglobulin epsilon receptor subunit gamma (FCER1G) as putative targets to be modulated for Alzheimer’s disease (AD) therapy. FCER1G is a component of Fc receptor complexes that contain an immunoreceptor tyrosine-based activation motif (ITAM). SYK interacts with the Fc receptor by binding to doubly phosphorylated ITAM (p-ITAM) via its two tandem SH2 domains (SYK-tSH2). Interaction of the FCER1G p-ITAM with SYK-tSH2 enables SYK activation via phosphorylation. Since SYK activation is reported to exacerbate AD pathology, we hypothesized that disruption of this interaction would be beneficial for AD patients. Herein, we developed biochemical and biophysical assays to enable the discovery of small molecules that perturb the interaction between the FCER1G p-ITAM and SYKtSH2. We identified two distinct chemotypes using a high-throughput screen (HTS) and orthogonally assessed their binding. Both chemotypes covalently modify SYK-tSH2 and inhibit its interaction with FCER1G p-ITAM, however, these compounds lack selectivity and this limits their utility as chemical tools

    Operation and performance of the ATLAS semiconductor tracker

    Get PDF
    The semiconductor tracker is a silicon microstrip detector forming part of the inner tracking system of the ATLAS experiment at the LHC. The operation and performance of the semiconductor tracker during the first years of LHC running are described. More than 99% of the detector modules were operational during this period, with an average intrinsic hit efficiency of (99.74±0.04)%. The evolution of the noise occupancy is discussed, and measurements of the Lorentz angle, Ύ-ray production and energy loss presented. The alignment of the detector is found to be stable at the few-micron level over long periods of time. Radiation damage measurements, which include the evolution of detector leakage currents, are found to be consistent with predictions and are used in the verification of radiation background simulations

    Measurement of the cross section of high transverse momentum Z→bb̄ production in proton–proton collisions at √s = 8 TeV with the ATLAS detector

    Get PDF
    This Letter reports the observation of a high transverse momentum Z→bb̄ signal in proton–proton collisions at √s=8 TeV and the measurement of its production cross section. The data analysed were collected in 2012 with the ATLAS detector at the LHC and correspond to an integrated luminosity of 19.5 fb−Âč. The Z→bb̄ decay is reconstructed from a pair of b -tagged jets, clustered with the anti-ktkt jet algorithm with R=0.4R=0.4, that have low angular separation and form a dijet with pT>200 GeVpT>200 GeV. The signal yield is extracted from a fit to the dijet invariant mass distribution, with the dominant, multi-jet background mass shape estimated by employing a fully data-driven technique that reduces the dependence of the analysis on simulation. The fiducial cross section is determined to be σZ→bbÂŻfid=2.02±0.20 (stat.) ±0.25 (syst.)±0.06 (lumi.) pb=2.02±0.33 pb, in good agreement with next-to-leading-order theoretical predictions

    Measurement of the branching ratio Γ(Λb⁰ → ψ(2S)Λ0)/Γ(Λb⁰ → J/ψΛ0) with the ATLAS detector

    Get PDF
    An observation of the Λb0→ψ(2S)Λ0\Lambda_b^0 \rightarrow \psi(2S) \Lambda^0 decay and a comparison of its branching fraction with that of the Λb0→J/ψΛ0\Lambda_b^0 \rightarrow J/\psi \Lambda^0 decay has been made with the ATLAS detector in proton--proton collisions at s=8 \sqrt{s}=8\,TeV at the LHC using an integrated luminosity of 20.6 20.6\,fb−1^{-1}. The J/ψJ/\psi and ψ(2S)\psi(2S) mesons are reconstructed in their decays to a muon pair, while the Λ0→pπ−\Lambda^0\rightarrow p\pi^- decay is exploited for the Λ0\Lambda^0 baryon reconstruction. The Λb0\Lambda_b^0 baryons are reconstructed with transverse momentum pT>10 p_{\rm T}>10\,GeV and pseudorapidity ∣η∣<2.1|\eta|<2.1. The measured branching ratio of the Λb0→ψ(2S)Λ0\Lambda_b^0 \rightarrow \psi(2S) \Lambda^0 and Λb0→J/ψΛ0\Lambda_b^0 \rightarrow J/\psi \Lambda^0 decays is Γ(Λb0→ψ(2S)Λ0)/Γ(Λb0→J/ψΛ0)=0.501±0.033(stat)±0.019(syst)\Gamma(\Lambda_b^0 \rightarrow \psi(2S)\Lambda^0)/\Gamma(\Lambda_b^0 \rightarrow J/\psi\Lambda^0) = 0.501\pm 0.033 ({\rm stat})\pm 0.019({\rm syst}), lower than the expectation from the covariant quark model.Comment: 12 pages plus author list (28 pages total), 5 figures, 1 table, published on Physics Letters B 751 (2015) 63-80. All figures are available at https://atlas.web.cern.ch/Atlas/GROUPS/PHYSICS/PAPERS/BPHY-2013-08
    • 

    corecore