1,173 research outputs found

    One-year treatment with mometasone furoate in chronic obstructive pulmonary disease

    Get PDF
    Many patients with chronic obstructive pulmonary disease (COPD) are treated with twice daily (BID) inhaled corticosteroids (ICS). This study evaluated whether daily PM mometasone furoate administered via a dry powder inhaler (MF-DPI) was equally effective compared to twice daily dosing

    Does unemployment in family affect pregnancy outcome in conditions of high quality maternity care?

    Get PDF
    BACKGROUND: The influence of unemployment in the family on pregnancy outcome is controversial. Only a few studies have involved investigation of the effect of unemployment of the father on pregnancy. The objective of this study was to assess the effects of unemployment of one or both parents on obstetric outcome in conditions of free antenatal care attended by the entire pregnant population. METHODS: The data of 24 939 pregnancies included maternal risk factors, pregnancy characteristics and outcome, and was based on a self administered questionnaire at 20 weeks of pregnancy and on clinical records. RESULTS: Unemployment was associated with adolescent maternal age, unmarried status and overweight, anemia, smoking, alcohol consumption and prior pregnancy terminations. Multivariate logistic regression analysis indicated that after controlling for these maternal risk factors small differences only were found in pregnancy outcomes between unemployed and employed families. Unemployed women had significantly more often small-for-gestational-age (SGA) infants, at an OR of 1.26 (95% CI: 1.12 – 1.42) whereas, in families where both parents were unemployed, the risk of SGA was even higher at an OR of 1.43 (95% CI: 1.18 – 1.73). Otherwise, pregnancy outcome was comparable in the groups studied. CONCLUSION: Free antenatal care was unable to fully overcome the adverse pregnancy outcomes associated with unemployment, SGA risk being highest when both parents are unemployed

    Accelerated decline in lung function in smoking women with airway obstruction: SAPALDIA 2 cohort study

    Get PDF
    BACKGROUND: The aim was to determine if effects from smoking on lung function measured over 11 years differ between men and women. METHODS: In a prospective population based cohort study (Swiss Study on Air Pollution and Lung Diseases in Adults) current smokers in 1991 (18 – 60 yrs) were reassessed in 2002 (n = 1792). Multiple linear regression was used to estimate effects from pack-years of cigarettes smoked to 1991 and mean packs of cigarettes smoked per day between 1991 and 2002 on change in lung volume and flows over the 11 years. RESULTS: In both sexes, packs smoked between assessments were related to lung function decline but pack-years smoked before 1991 were not. Mean annual decline in FEV(1 )was -10.4 mL(95%CI -15.3, -5.5) per pack per day between assessments in men and -13.8 mL(95%CI-19.5,-8.1) in women. Decline per pack per day between 1991 and 2002 was lower in women who smoked in 1991 but quit before 2002 compared to persistent smokers (-6.4 vs -11.6 mL, p = 0.05) but this was not seen in men (-14.3 vs -8.8 mL p = 0.49). Smoking related decline was accelerated in men and women with airway obstruction, particularly in women where decline in FEV(1 )was three fold higher in participants with FEV1/FVC<0.70 compared to other women (-39.4 vs -12.2 mL/yr per pack per day, p < 0.002). CONCLUSION: There are differences in effects from smoking on lung function between men and women. Lung function recovers faster in women quitters than in men. Women current smokers with airway obstruction experience a greater smoking related decline in lung function than men

    Prevalence of anatomical variants and coronary anomalies in 543 consecutive patients studied with 64-slice CT coronary angiography

    Get PDF
    The aim of our study was to assess the prevalence of variants and anomalies of the coronary artery tree in patients who underwent 64-slice computed tomography coronary angiography (CT-CA) for suspected or known coronary artery disease. A total of 543 patients (389 male, mean age 60.5 ± 10.9) were reviewed for coronary artery variants and anomalies including post-processing tools. The majority of segments were identified according to the American Heart Association scheme. The coronary dominance pattern results were: right, 86.6%; left, 9.2%; balanced, 4.2%. The left main coronary artery had a mean length of 112 ± 55 mm. The intermediate branch was present in the 21.9%. A variable number of diagonals (one, 25%; two, 49.7%; more than two, 24%; none, 1.3%) and marginals (one, 35.2%; two, 46.2%; more than two, 18%; none, 0.6%) was visualized. Furthermore, CT-CA may visualize smaller branches such as the conus branch artery (98%), the sinus node artery (91.6%), and the septal branches (93%). Single or associated coronary anomalies occurred in 18.4% of the patients, with the following distribution: 43 anomalies of origin and course, 68 intrinsic anomalies (59 myocardial bridging, nine aneurisms), three fistulas. In conclusion, 64-slice CT-CA provides optimal visualization of the variable and complex anatomy of coronary arteries because of the improved isotropic spatial resolution and flexible post-processing tool

    Optimisation of the conditions for stripping voltammetric analysis at liquid-liquid interfaces supported at micropore arrays: a computational simulation

    Get PDF
    Micropore membranes have been used to form arrays of micro interfaces between immiscible electroly tesolutions (ÎŒITIES) as a basis for the sensing of non-redoxactiveions. Implementation of stripping voltammetry as asensing method at these arrays of ÎŒITIES was applied recently to detect drugs and biomolecules at low concentrations. The present study uses computational simulation to investigate the optimum conditions for stripping voltammetricsensing at the ÎŒITIES array. In this scenario, thediffusion of ions in both the aqueous and the organic phasescontributes to the sensing response. The influence of the preconcentration time, the micropore aspect ratio, the location of the micro interface within the pore, the ratio of the diffusion coefficients of the analyte ion in the organic and aqueous phases, and the pore wall angle were investigated. The simulations reveal that the accessibility of the microinterfaces during the preconcentration period should not be hampered by a recessed interface and that diffusional transport in the phase where the analyte ions are preconcentrated should be minimized. This will ensure that the ions are accumulated within the micropores close to the interface and thus be readily available for back transferduring the stripping process. On the basis of the results, an optimal combination of the examined parameters is proposed,which together improve the stripping voltammetric signal and provide an improvement in the detection limit

    Search for new phenomena in final states with an energetic jet and large missing transverse momentum in pp collisions at √ s = 8 TeV with the ATLAS detector

    Get PDF
    Results of a search for new phenomena in final states with an energetic jet and large missing transverse momentum are reported. The search uses 20.3 fb−1 of √ s = 8 TeV data collected in 2012 with the ATLAS detector at the LHC. Events are required to have at least one jet with pT > 120 GeV and no leptons. Nine signal regions are considered with increasing missing transverse momentum requirements between Emiss T > 150 GeV and Emiss T > 700 GeV. Good agreement is observed between the number of events in data and Standard Model expectations. The results are translated into exclusion limits on models with either large extra spatial dimensions, pair production of weakly interacting dark matter candidates, or production of very light gravitinos in a gauge-mediated supersymmetric model. In addition, limits on the production of an invisibly decaying Higgs-like boson leading to similar topologies in the final state are presente

    H2FPEF score predicts atherosclerosis presence in patients with systemic connective tissue disease

    Get PDF
    Background: Cardiovascular diseases are common cause of morbidity and mortality in patients with systemic connective tissue diseases (SCTD) due to accelerated atherosclerosis which couldn't be explained by traditional risk factors (CVDRF). Hypothesis: We hypothesized that recently developed score predicting probability of heart failure with preserved ejection fraction (H2FPEF), as well as a measure of right ventricular-pulmonary vasculature coupling [tricuspid annular plane systolic excursion (TAPSE)/pulmonary artery systolic pressure (PASP) ratio], are predictive of atherosclerosis in SCTD. Methods: 203 patients (178 females) diagnosed with SCTD underwent standard and stress-echocardiography (SE) with TAPSE/PASP and left ventricular (LV) diastolic filling pressure (E/e') measurements, carotid ultrasound and computed tomographic coronary angiography. Patients who were SE positive for ischemia underwent coronary angiography (34/203). The H2FPEF score was calculated according to age, body mass index, presence of atrial fibrillation, ≄2 antihypertensives, E/e' and PASP. Results: Mean LV ejection fraction was 66.3 ± 7.1%. Atherosclerosis was present in 150/203 patients according to: 1) intima-media thickness>0.9 mm; and 2) Agatstone score > 300 or Syntax score ≄ 1. On binary logistic regression analysis, including CVDRF prevalence, echocardiographic parameters and H2FPEF score, only H2FPEF score remained significant for the prediction of atherosclerosis presence (χ2 = 19.3, HR 2.6, CI 1.5-4.3, p < 0.001), and resting TAPSE/PASP for the prediction of a SE positive for ischemia (χ2 = 10.4, HR 0.01, CI = 0.01-0.22, p = 0.004). On ROC analysis, the optimal threshold value for identifying patients with atherosclerosis was a H2FPEF score ≄2 (Sn 60.4%, Sp 69.4%, area 0.67, SE = 0.05, p < 0.001). Conclusions: H2FPEF score and resting TAPSE/PASP demonstrated clinical value for an atherosclerosis diagnosis in patients diagnosed with SCTD

    Measurement of the cross-section of high transverse momentum vector bosons reconstructed as single jets and studies of jet substructure in pp collisions at √s = 7 TeV with the ATLAS detector

    Get PDF
    This paper presents a measurement of the cross-section for high transverse momentum W and Z bosons produced in pp collisions and decaying to all-hadronic final states. The data used in the analysis were recorded by the ATLAS detector at the CERN Large Hadron Collider at a centre-of-mass energy of √s = 7 TeV;{\rm Te}{\rm V}andcorrespondtoanintegratedluminosityof and correspond to an integrated luminosity of 4.6\;{\rm f}{{{\rm b}}^{-1}}.ThemeasurementisperformedbyreconstructingtheboostedWorZbosonsinsinglejets.ThereconstructedjetmassisusedtoidentifytheWandZbosons,andajetsubstructuremethodbasedonenergyclusterinformationinthejetcentre−of−massframeisusedtosuppressthelargemulti−jetbackground.Thecross−sectionforeventswithahadronicallydecayingWorZboson,withtransversemomentum. The measurement is performed by reconstructing the boosted W or Z bosons in single jets. The reconstructed jet mass is used to identify the W and Z bosons, and a jet substructure method based on energy cluster information in the jet centre-of-mass frame is used to suppress the large multi-jet background. The cross-section for events with a hadronically decaying W or Z boson, with transverse momentum {{p}_{{\rm T}}}\gt 320\;{\rm Ge}{\rm V}andpseudorapidity and pseudorapidity |\eta |\lt 1.9,ismeasuredtobe, is measured to be {{\sigma }_{W+Z}}=8.5\pm 1.7$ pb and is compared to next-to-leading-order calculations. The selected events are further used to study jet grooming techniques
    • 

    corecore