110 research outputs found

    Nanoscale superconducting properties of amorphous W-based deposits grown with focused-ion-beam

    Full text link
    We present very low temperature Scanning Tunneling Microscopy and Spectroscopy (STM/S) measurements in W-based amorphous superconducting nanodeposits grown using a metal-organic precursor and focused-ion-beam. The superconducting gap closely follows s-wave BCS theory, and STS images under magnetic fields show a hexagonal vortex lattice whose orientation is related to features observed in the topography through STM. Our results demonstrate that the superconducting properties at the surface of these deposits are very homogeneous, down to atomic scale. This, combined with the huge nanofabrication possibilities of the focused-ion-beam technique, paves the way to use focused-ion-beam to make superconducting circuitry of many different geometries

    Ruminal fermentation pattern of acidosis-induced cows fed either monensin or polyclonal antibodies preparation against several ruminal bacteria

    Get PDF
    This study was designed to evaluate a spray-dried multivalent polyclonal antibody preparation (PAP) against lactate-producing bacteria as an alternative to monensin (MON) to control ruminal acidification. Holstein cows (677 ± 98 kg) fitted with ruminal cannulas were allocated in an incomplete Latin square design with two 20 days period. Cows were randomly assigned to control (CTL), PAP, or MON treatments. For each period, cows were fed a forage diet in the first 5 days (d−5 to d−1), composed of sugarcane, urea and a mineral supplement, followed by a 74% concentrate diet for 15 days (d 0 to d 14). There were no treatment main effects (P > 0.05) on dry matter intake (DMI) and microbial protein synthesis. However, there was a large peak (P < 0.01) of intake on d 0 (18.29 kg), followed by a large decline on d 1 (3.67 kg). From d2, DMI showed an increasing pattern (8.34 kg) and stabilized around d 8 (12.96 kg). Higher mean pH was measured (P < 0.01) in cattle-fed MON (6.06 vs. PAP = 5.89 and CTL = 5.91). The ruminal NH3-N concentration of CTL-fed cows was lower (P < 0.01) compared to those fed MON or PAP. The molar concentration of acetate and lactate was not affected (P > 0.23) by treatments, but feeding MON increased (P = 0.01) propionate during the first 4 days after the challenge. Feeding MON and PAP reduced (P = 0.01) the molar proportion of butyrate. MON was effective in controlling pH and improved ruminal fermentation of acidosis-induced cows. However, PAP was not effective in controlling acidosis. The acidosis induced by the challenge was caused by the accumulation of SCFAs. Therefore, the real conditions for evaluation of this feed additive were not reached in this experiment, since this PAP was proposed to work against lactate-producing bacteria

    GAUDI: a preparatory archive for the COROT mission

    Get PDF
    The GAUDI database (Ground-based Asteroseismology Uniform Database Interface, http://sdc.laeff.esa.es/gaudi/) is a preparatory archive for the COROT (COnvection, ROtation and planetary Transits, http://www.astrsp-mrs.fr/projets/corot/) mission developed at LAEFF (Laboratory for Space Astrophysics and Theoretical Physics, http://www.laeff.esa.es). Its intention is to make the ground-based observations obtained in the preparation of the asteroseismology programme available in a simple and efficient way. It contains spectroscopic and photometric data together with inferred physical parameters for more than 1500 objects gathered since January 1998 in 6 years of observational campaigns. In this paper, the main functionalities and characteristics of the system are described. The observations have been collected at ESO-La Silla, Telescopio Nazionale Galileo, Observatoire de Haute-Provence, South African Astronomical Observatory, Tautenberg Observatory and Sierra Nevada Observatory.Comment: 12 pages, 3 figures (quality degraded). Accepted for publication in The Astronomical Journa

    Measurements of branching fraction ratios and CP asymmetries in B+/- ->D_CP K+/- decays in hadron collisions

    Get PDF
    We reconstruct B+/- -> D K+/- decays in a data sample collected by the CDF II detector at the Tevatron collider corresponding to 1 fb-1 of integrated luminosity. We select decay modes where the D meson decays to either K- pi+ (flavor eigenstate) or K- K+, pi- pi+ (CP-even eigenstates), and measure the direct CP asymmetry A_CP+ = 0.39 +/- 0.17(stat) +/- 0.04(syst), and the double ratio of CP-even to flavor eigenstate branching fractions R_CP+ = 1.30 +/- 0.24(stat) +/- 0.12(syst). These measurements will improve the determination of the CKM angle gamma. They are performed here for the first time using data from hadron collisions.We reconstruct B±→DK± decays in a data sample collected by the CDF II detector at the Tevatron collider corresponding to 1  fb-1 of integrated luminosity. We select decay modes where the D meson decays to either K-π+ (flavor eigenstate) or K-K+, π-π+ (CP-even eigenstates), and measure the direct CP asymmetry ACP+=0.39±0.17(stat)±0.04(syst), and the double ratio of CP-even to flavor eigenstate branching fractions RCP+=1.30±0.24(stat)±0.12(syst). These measurements will improve the determination of the Cabibbo-Kobayashi-Maskawa angle γ. They are performed here for the first time using data from hadron collisions.Peer reviewe

    Search for Supersymmetry with Gauge-Mediated Breaking in Diphoton Events with Missing Transverse Energy at CDF II

    Get PDF
    accepted to Phys. Rev. LettWe present the results of a search for supersymmetry with gauge-mediated breaking and \NONE\to\gamma\Gravitino in the γγ\gamma\gamma+missing transverse energy final state. In 2.6±\pm0.2 \invfb of ppˉp{\bar p} collisions at s\sqrt{s}==1.96 TeV recorded by the CDF II detector we observe no candidate events, consistent with a standard model background expectation of 1.4±\pm0.4 events. We set limits on the cross section at the 95% C.L. and place the world's best limit of 149\gevc on the \none mass at τχ~10\tau_{\tilde{\chi}_1^0}$We present the results of a search for supersymmetry with gauge-mediated breaking and χ˜10→γG˜ in the γγ+missing transverse energy final state. In 2.6±0.2  fb-1 of pp̅ collisions at √s=1.96  TeV recorded by the CDF II detector we observe no candidate events, consistent with a standard model background expectation of 1.4±0.4 events. We set limits on the cross section at the 95% C.L. and place the world’s best limit of 149  GeV/c2 on the χ˜10 mass at τχ˜10≪1  ns. We also exclude regions in the χ˜10 mass-lifetime plane for τχ˜10≲2  ns.Peer reviewe

    Alignment of the CMS silicon tracker during commissioning with cosmic rays

    Get PDF
    This is the Pre-print version of the Article. The official published version of the Paper can be accessed from the link below - Copyright @ 2010 IOPThe CMS silicon tracker, consisting of 1440 silicon pixel and 15 148 silicon strip detector modules, has been aligned using more than three million cosmic ray charged particles, with additional information from optical surveys. The positions of the modules were determined with respect to cosmic ray trajectories to an average precision of 3–4 microns RMS in the barrel and 3–14 microns RMS in the endcap in the most sensitive coordinate. The results have been validated by several studies, including laser beam cross-checks, track fit self-consistency, track residuals in overlapping module regions, and track parameter resolution, and are compared with predictions obtained from simulation. Correlated systematic effects have been investigated. The track parameter resolutions obtained with this alignment are close to the design performance.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)

    Commissioning and performance of the CMS pixel tracker with cosmic ray muons

    Get PDF
    This is the Pre-print version of the Article. The official published verion of the Paper can be accessed from the link below - Copyright @ 2010 IOPThe pixel detector of the Compact Muon Solenoid experiment consists of three barrel layers and two disks for each endcap. The detector was installed in summer 2008, commissioned with charge injections, and operated in the 3.8 T magnetic field during cosmic ray data taking. This paper reports on the first running experience and presents results on the pixel tracker performance, which are found to be in line with the design specifications of this detector. The transverse impact parameter resolution measured in a sample of high momentum muons is 18 microns.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)

    Performance of the CMS drift-tube chamber local trigger with cosmic rays

    Get PDF
    The performance of the Local Trigger based on the drift-tube system of the CMS experiment has been studied using muons from cosmic ray events collected during the commissioning of the detector in 2008. The properties of the system are extensively tested and compared with the simulation. The effect of the random arrival time of the cosmic rays on the trigger performance is reported, and the results are compared with the design expectations for proton-proton collisions and with previous measurements obtained with muon beams

    Elective Cancer Surgery in COVID-19-Free Surgical Pathways During the SARS-CoV-2 Pandemic: An International, Multicenter, Comparative Cohort Study.

    Get PDF
    PURPOSE: As cancer surgery restarts after the first COVID-19 wave, health care providers urgently require data to determine where elective surgery is best performed. This study aimed to determine whether COVID-19-free surgical pathways were associated with lower postoperative pulmonary complication rates compared with hospitals with no defined pathway. PATIENTS AND METHODS: This international, multicenter cohort study included patients who underwent elective surgery for 10 solid cancer types without preoperative suspicion of SARS-CoV-2. Participating hospitals included patients from local emergence of SARS-CoV-2 until April 19, 2020. At the time of surgery, hospitals were defined as having a COVID-19-free surgical pathway (complete segregation of the operating theater, critical care, and inpatient ward areas) or no defined pathway (incomplete or no segregation, areas shared with patients with COVID-19). The primary outcome was 30-day postoperative pulmonary complications (pneumonia, acute respiratory distress syndrome, unexpected ventilation). RESULTS: Of 9,171 patients from 447 hospitals in 55 countries, 2,481 were operated on in COVID-19-free surgical pathways. Patients who underwent surgery within COVID-19-free surgical pathways were younger with fewer comorbidities than those in hospitals with no defined pathway but with similar proportions of major surgery. After adjustment, pulmonary complication rates were lower with COVID-19-free surgical pathways (2.2% v 4.9%; adjusted odds ratio [aOR], 0.62; 95% CI, 0.44 to 0.86). This was consistent in sensitivity analyses for low-risk patients (American Society of Anesthesiologists grade 1/2), propensity score-matched models, and patients with negative SARS-CoV-2 preoperative tests. The postoperative SARS-CoV-2 infection rate was also lower in COVID-19-free surgical pathways (2.1% v 3.6%; aOR, 0.53; 95% CI, 0.36 to 0.76). CONCLUSION: Within available resources, dedicated COVID-19-free surgical pathways should be established to provide safe elective cancer surgery during current and before future SARS-CoV-2 outbreaks
    corecore