Flavonoids are inactivated by phase II metabolism and occur in the body as glucuronides. Mammalian Ă-glucuronidase released from neutrophils at inflammatory sites may be able to deconjugate and thus activate flavonoid glucuronides. We have studied deconjugation kinetics and pH optimum for four sources of Ă-glucuronidase (human neutrophil, human recombinant, myeloid PLB-985 cells, Helix pomatia) with five flavonoid glucuronides (quercetin-3-glucuronide, quercetin-3'-glucuronide, quercetin-4'-glucuronide, quercetin-7-glucuronide, 3'-methylquercetin-3-glucuronide), 4-methylumbelliferyl-Ă-D-glucuronide, and para-nitrophenol-glucuronide. All substrate-enzyme combinations tested exhibited first order kinetics. The optimum pH for hydrolysis was between 3.5-5, with appreciable hydrolysis activities up to pH 5.5. At pH 4, the Km ranged 44-fold from 22 ”M for quercetin-4'-glucuronide with Helix pomatia Ă-glucuronidase, to 981 ”M for para-nitrophenol-glucuronide with recombinant Ă-glucuronidase. Vmax (range: 0.735-24.012 ”mol·min-1·unit-1 [1 unit is defined as the release of 1 ”M 4-methylumbelliferyl-Ă-D-glucuronide per min]) and the reaction rate constants at low substrate concentrations (k) (range: 0.002-0.062 min-1·(unit/L)-1 were similar for all substrates-enzyme combinations tested. In conclusion, we show that Ă-glucuronidase from four different sources, including human neutrophils, is able to deconjugate flavonoid glucuronides and non-flavonoid substrates at fairly similar kinetic rates. At inflammatory sites in vivo the pH, neutrophil and flavonoid glucuronide concentrations seem favorable for deconjugation. However, it remains to be confirmed whether this is actually the case
Deconjugation Kinetics of Glucuronidated Phase II Flavonoid Metabolites by beta-glucuronidase from Neutrophils
The clinical impact of phase offset errors and different correction methods in cardiovascular magnetic resonance phase contrast imaging: a multi-scanner study
Background: Cardiovascular magnetic resonance (CMR) phase contrast (PC) flow measurements suffer from phase
offset errors. Background subtraction based on stationary phantom measurements can most reliably be used to
overcome this inaccuracy. Stationary tissue correction is an alternative and does not require additional phantom
scanning. The aim of this study was 1) to compare measurements with and without stationary tissue correction to
phantom corrected measurements on different GE Healthcare CMR scanners using different software packages and
2) to evaluate the clinical implications of these methods.
Methods: CMR PC imaging of both the aortic and pulmonary artery flow was performed in patients on three
different 1.5 T CMR scanners (GE Healthcare) using identical scan parameters. Uncorrected, first, second and third
order stationary tissue corrected flow measurement were compared to phantom corrected flow measurements, our
reference method, using Medis QFlow, Circle cvi42 and MASS software. The optimal (optimized) stationary tissue
order was determined per scanner and software program. Velo
Quantum theory of the far-off-resonance continuous-wave Raman laser: Heisenberg-Langevin approach
We present the quantum theory of the far-off-resonance continuous-wave Raman laser using the Heisenberg-Langevin approach. We show that the simplified quantum Langevin equations for this system are mathematically identical to those of the nondegenerate optical parametric oscillator in the time domain with the following associations: pump pump, Stokes signal, and Raman coherence idler. We derive analytical results for both the steady-state behavior and the time-dependent noise spectra, using standard linearization procedures. In the semiclassical limit, these results match with previous purely semiclassical treatments, which yield excellent agreement with experimental observations. The analytical time-dependent results predict perfect photon statistics conversion from the pump to the Stokes and nonclassical behavior under certain operational conditions
Active Galactic Nuclei at the Crossroads of Astrophysics
Over the last five decades, AGN studies have produced a number of spectacular
examples of synergies and multifaceted approaches in astrophysics. The field of
AGN research now spans the entire spectral range and covers more than twelve
orders of magnitude in the spatial and temporal domains. The next generation of
astrophysical facilities will open up new possibilities for AGN studies,
especially in the areas of high-resolution and high-fidelity imaging and
spectroscopy of nuclear regions in the X-ray, optical, and radio bands. These
studies will address in detail a number of critical issues in AGN research such
as processes in the immediate vicinity of supermassive black holes, physical
conditions of broad-line and narrow-line regions, formation and evolution of
accretion disks and relativistic outflows, and the connection between nuclear
activity and galaxy evolution.Comment: 16 pages, 5 figures; review contribution; "Exploring the Cosmic
Frontier: Astrophysical Instruments for the 21st Century", ESO Astrophysical
Symposia Serie
Cardiovascular morbidity and mortality in adult patients with repaired aortic coarctation
BACKGROUND: The longâterm burden of cardiovascular disease after repair of coarctation of the aorta (CoA) has not been elucidated. We aimed to determine the incidence of and risk factors for cardiovascular events in adult patients with repaired CoA. Additionally, mortality rates were compared between adults with repaired CoA and the general population. METHODS AND RESULTS: Using the Dutch Congenital Corvitia (CONCOR) registry, patients aged â„16 years with previous surgical or transcatheter CoA repair from 5 tertiary referral centers were included. Cardiovascular events were recorded, comprising coronary artery disease, stroke/transient ischemic attack, aortic complications, arrhythmias, heart failure hospitalizations, endocarditis, and cardiovascular death. In total, 920 patients (median age, 24 years [range 16â74 years]) were included. After a mean followâup of 9.3±5.1 years, 191 patients (21%) experienced at least 1 cardiovascular event. A total of 270 cardiovascular events occurred, of which aortic complications and arrhythmias were most frequent. Older age at initial CoA repair (hazard ratio [HR], 1.017; 95% CI, 1.000â1.033 [P=0.048]) and elevated left ventricular mass index (HR, 1.009; 95% CI, 1.005â1.013 [P<0.001]) were independently associated with an increased risk of cardiovascular events. The mortality rate was 3.3 times higher than expected based on an ageâ and sexâmatched cohort from the Dutch general population (standardized mortality ratio, 3.3; 95% CI, 2.3â4.4 [P<0.001]). CONCLUSIONS: This large, prospective cohort of adults with repaired CoA showed a high burden of cardiovascular events, particularly aortic complications and arrhythmias, during longâterm followâup. Older age at initial CoA repair and elevated left ventricular mass index were independent risk factors for the occurrence of cardiovascular events. Mortality was 3.3âfold higher compared with the general population. These results advocate stringent followâup after CoA repair and emphasize the need for improved preventive strategies
Qualitative grading of aortic regurgitation: a pilot study comparing CMR 4D flow and echocardiography
Over the past 10Â years there has been intense research in the development of volumetric visualization of intracardiac flow by cardiac magnetic resonance (CMR). This volumetric time resolved technique called CMR 4D flow imaging has several advantages over standard CMR. It offers anatomical, functional and flow information in a single free-breathing, ten-minute acquisition. However, the data obtained is large and its processing requires dedicated software. We evaluated a cloud-based application package that combines volumetric data correction and visualization of CMR 4D flow data, and assessed its accuracy for the detection and grading of aortic valve regurgitation using transthoracic echocardiography as reference. Between June 2014 and January 2015, patients planned for clinical CMR were consecutively approached to undergo the supplementary CMR 4D flow acquisition. Fifty four patients (median age 39Â years, 32 males) were included. Detection and grading of the aortic valve regurgitation using CMR 4D flow imaging were evaluated against transthoracic echocardiography. The agreement between 4D flow CMR and transthoracic echocardiography for grading of aortic valve regurgitation was good (ÎșÂ =Â 0.73). To identify relevant, more than mild aortic valve regurgitation, CMR 4D flow imaging had a sensitivity of 100Â % and specificity of 98Â %. Aortic regurgitation can be well visualized, in a similar manner as transthoracic echocardiography, when using CMR 4D flow imaging
Measurement of the B0-anti-B0-Oscillation Frequency with Inclusive Dilepton Events
The - oscillation frequency has been measured with a sample of
23 million \B\bar B pairs collected with the BABAR detector at the PEP-II
asymmetric B Factory at SLAC. In this sample, we select events in which both B
mesons decay semileptonically and use the charge of the leptons to identify the
flavor of each B meson. A simultaneous fit to the decay time difference
distributions for opposite- and same-sign dilepton events gives ps.Comment: 7 pages, 1 figure, submitted to Physical Review Letter
Search for direct production of charginos and neutralinos in events with three leptons and missing transverse momentum in âs = 7 TeV pp collisions with the ATLAS detector
A search for the direct production of charginos and neutralinos in final states with three electrons or muons and missing transverse momentum is presented. The analysis is based on 4.7 fbâ1 of protonâproton collision data delivered by the Large Hadron Collider and recorded with the ATLAS detector. Observations are consistent with Standard Model expectations in three signal regions that are either depleted or enriched in Z-boson decays. Upper limits at 95% confidence level are set in R-parity conserving phenomenological minimal supersymmetric models and in simplified models, significantly extending previous results
Jet size dependence of single jet suppression in lead-lead collisions at sqrt(s(NN)) = 2.76 TeV with the ATLAS detector at the LHC
Measurements of inclusive jet suppression in heavy ion collisions at the LHC
provide direct sensitivity to the physics of jet quenching. In a sample of
lead-lead collisions at sqrt(s) = 2.76 TeV corresponding to an integrated
luminosity of approximately 7 inverse microbarns, ATLAS has measured jets with
a calorimeter over the pseudorapidity interval |eta| < 2.1 and over the
transverse momentum range 38 < pT < 210 GeV. Jets were reconstructed using the
anti-kt algorithm with values for the distance parameter that determines the
nominal jet radius of R = 0.2, 0.3, 0.4 and 0.5. The centrality dependence of
the jet yield is characterized by the jet "central-to-peripheral ratio," Rcp.
Jet production is found to be suppressed by approximately a factor of two in
the 10% most central collisions relative to peripheral collisions. Rcp varies
smoothly with centrality as characterized by the number of participating
nucleons. The observed suppression is only weakly dependent on jet radius and
transverse momentum. These results provide the first direct measurement of
inclusive jet suppression in heavy ion collisions and complement previous
measurements of dijet transverse energy imbalance at the LHC.Comment: 15 pages plus author list (30 pages total), 8 figures, 2 tables,
submitted to Physics Letters B. All figures including auxiliary figures are
available at
http://atlas.web.cern.ch/Atlas/GROUPS/PHYSICS/PAPERS/HION-2011-02
- âŠ