462 research outputs found

    Prevalencia serológica de Salmonella pullorum en algunos planteles de reproducción de aves durante 1981.

    Get PDF
    Dado que recientemente y en diferentes regiones del país se tiene conocimiento de la presencia en aves de reproducción de brotes severos ocasionados por la cepa variante de Salmonella pullorum, se estudia la prevalencia serológica en 7 planteles avícolas de reproducción localizados en 4 departamentos de Colombia. Se analizaron 818 sueros y se emplea la prueba de seroaglutinación en placa a temperatura ambiente con lectura máxima hasta de 5 minutos, enfrentando los sueros a los antígenos estandar, bivalente y variante. La prevalencia encontrada fue respectivamente de 1.2, 4.4 y 3.7 por ciento. La reactividad serológica demuestra la existencia de un contacto anterior o actual de las aves con el microorganismo. Estos resultados se consideran altamente indicativos de la presencia de S. pullorum tipo variante en algunos planteles de reproductoras del país. Se recomienda la implantación obligatoria del uso del antígeno bivalente en las pruebas de diagnóstico y control de la enfermedad. Igualmente, emprender programas de eliminación e incineración especialmente en las aves de reproducción de todos los reactores positivos. Para una mejor vigilancia epidemiológica, se sugiere que anualmente se reporten al ICA resultados de estas pruebas adelantadas por los médicos veterinarios de asistencia técnica particular en las granjas avícolas de reproducción para establecer estadísticas confiables sobre presencia de cepas móviles o inmóviles de esta enfermedadAvicultur

    Process design for the manufacturing of soft X-ray gratings in single-crystal diamond by high-energy heavy-ion irradiation

    Get PDF
    Artículo con 9 figurasThis paper describes in detail a novel manufacturing process for optical gratings suitable for use in the UV and soft X-ray regimes in a single-crystal diamond substrate based on highly focused swift heavy-ion irradiation. This type of grating is extensively used in light source facilities such as synchrotrons or free electron lasers, with ever-increasing demands in terms of thermal loads, depending on beamline operational parameters and architecture. The process proposed in this paper may be a future alternative to current manufacturing techniques, providing the advantage of being applicable to single-crystal diamond substrates, with their unique properties in terms of heat conductivity and radiation hardness. The paper summarizes the physical principle used for the grating patterns produced by swift heavy-ion irradiation and provides full details for the manufacturing process for a specific grating configuration, inspired in one of the beamlines at the ALBA synchrotron light source, while stressing the most challenging points for a potential implementation. Preliminary proof-of-concept experimental results are presented, showing the practical implementation of the methodology proposed herein.The authors acknowledge funding support by the following projects: PID2020-112770RB-C22 from the Spanish Ministry of Science and Innovation, TechnoFusión (III)-CM (S2018/EMT-4437) from Comunidad de Madrid (cofinanced by ERDF and ESF), agreement between Community of Madrid and Universidad Autónoma de Madrid (item “Excellence of University Professorate”). M.L.C. acknowledges financial support from the research project “Captacion de Talento UAM” Ref: #541D300 supervised by the Vice-Chancellor of Research of Universidad Autónoma de Madrid (UAM). LOREA beamline at ALBA is a project co-funded by the European Regional Development Fund (ERDF) within the Framework of the Smart Growth Operative Programme 2014-2020. The authors acknowledge the support from The Centro de Microanálisis de Materiales (CMAM)—Universidad Autónoma de Madrid, for the beam time proposal (demonstration of a grating profile for soft X-rays in diamond via ion lithography) with code IuB-005/21, and its technical staff for their contribution to the operation of the accelerator. We also acknowledge P. Olivero for very useful comments on the manuscript draf

    Efficacy of direct current generated by multiple-electrode arrays on F3II mammary carcinoma: experiment and mathematical modeling

    Get PDF
    BACKGROUND: The modified Gompertz equation has been proposed to fit experimental data for direct current treated tumors when multiple-straight needle electrodes are individually inserted into the base perpendicular to the tumor long axis. The aim of this work is to evaluate the efficacy of direct current generated by multiple-electrode arrays on F3II mammary carcinoma that grow in the male and female BALB/c/Cenp mice, when multiple-straight needle electrodes and multiple-pairs of electrodes are inserted in the tumor. METHODS: A longitudinal and retrospective preclinical study was carried out. Male and female BALB/c/Cenp mice, the modified Gompertz equation, intensities (2, 6 and 10 mA) and exposure times (10 and 20 min) of direct current, and three geometries of multiple-electrodes (one formed by collinear electrodes and two by pair-electrodes) were used. Tumor volume and mice weight were measured. In addition, the mean tumor doubling time, tumor regression percentage, tumor growth delay, direct current overall effectiveness and mice survival were calculated. RESULTS: The greatest growth retardation, mean doubling time, regression percentage and growth delay of the primary F3II mammary carcinoma in male and female mice were observed when the geometry of multiple-pairs of electrodes was arranged in the tumor at 45, 135, 225 and 325o and the longest exposure time. In addition, highest direct current overall effectiveness (above 66%) was observed for this EChT scheme. CONCLUSIONS: It is concluded that electrochemical therapy may be potentially addressed to highly aggressive and metastic primary F3II murine mammary carcinoma and the modified Gompertz equation may be used to fit data of this direct current treated carcinoma. Additionally, electrochemical therapy effectiveness depends on the exposure time, geometry of multiple-electrodes and ratio between the direct current intensity applied and the polarization current induced in the tumor

    Distribution and outcomes of a phenotype-based approach to guide COPD management: Results from the CHAIN cohort

    Get PDF
    Rationale: The Spanish guideline for COPD (GesEPOC) recommends COPD treatment according to four clinical phenotypes: non-exacerbator phenotype with either chronic bronchitis or emphysema (NE), asthma-COPD overlap syndrome (ACOS), frequent exacerbator phenotype with emphysema (FEE) or frequent exacerbator phenotype with chronic bronchitis (FECB). However, little is known on the distribution and outcomes of the four suggested phenotypes. Objective: We aimed to determine the distribution of these COPD phenotypes, and their relation with one-year clinical outcomes. Methods: We followed a cohort of well-characterized patients with COPD up to one-year. Baseline characteristics, health status (CAT), BODE index, rate of exacerbations and mortality up to one year of follow-up were compared between the four phenotypes. Results: Overall, 831 stable COPD patients were evaluated. They were distributed as NE, 550 (66.2%); ACOS, 125 (15.0%); FEE, 38 (4.6%); and FECB, 99 (11.9%); additionally 19 (2.3%) COPD patients with frequent exacerbations did not fulfill the criteria for neither FEE nor FECB. At baseline, there were significant differences in symptoms, FEV1 and BODE index (all p<0.05). The FECB phenotype had the highest CAT score (17.1±8.2, p<0.05 compared to the other phenotypes). Frequent exacerbator groups (FEE and FECB) were receiving more pharmacological treatment at baseline, and also experienced more exacerbations the year after (all p<0.05) with no differences in one-year mortality. Most of NE (93%) and half of exacerbators were stable after one year. Conclusions: There is an uneven distribution of COPD phenotypes in stable COPD patients, with significant differences in demographics, patient-centered outcomes and health care resources use

    Influence of the length of hospitalisation in post-discharge outcomes in patients with acute heart failure: Results of the LOHRCA study

    Get PDF
    Objective: To investigate the relationship between length of hospitalisation (LOH) and post-discharge outcomes in acute heart failure (AHF) patients and to ascertain whether there are different patterns according to department of initial hospitalisation. Methods: Consecutive AHF patients hospitalised in 41 Spanish centres were grouped based on the LOH (15 days). Outcomes were defined as 90-day post-discharge all-cause mortality, AHF readmissions, and the combination of both. Hazard ratios (HRs), adjusted by chronic conditions and severity of decompensation, were calculated for groups with LOH >6 days vs. LOH <6 days (reference), and stratified by hospitalisation in cardiology, internal medicine, geriatrics, or short-stay units. Results: We included 8563 patients (mean age: 80 (SD = 10) years, 55.5% women), with a median LOH of 7 days (IQR 4–11): 2934 (34.3%) had a LOH 15 days. The 90-day post-discharge mortality was 11.4%, readmission 32.2%, and combined endpoint 37.4%. Mortality was increased by 36.5% (95%CI = 13.0–64.9) when LOH was 11–15 days, and by 72.0% (95%CI = 42.6–107.5) when >15 days. Conversely, no differences were found in readmission risk, and the combined endpoint only increased 21.6% (95%CI = 8.4–36.4) for LOH >15 days. Stratified analysis by hospitalisation departments rendered similar post-discharge outcomes, with all exhibiting increased mortality for LOH >15 days and no significant increments in readmission risk. Conclusions: Short hospitalisations are not associated with worse outcomes. While post-discharge readmissions are not affected by LOH, mortality risk increases as the LOH lengthens. These findings were similar across hospitalisation departments

    Evidence for a mixed mass composition at the `ankle' in the cosmic-ray spectrum

    Get PDF
    We report a first measurement for ultra-high energy cosmic rays of the correlation between the depth of shower maximum and the signal in the water Cherenkov stations of air-showers registered simultaneously by the fluorescence and the surface detectors of the Pierre Auger Observatory. Such a correlation measurement is a unique feature of a hybrid air-shower observatory with sensitivity to both the electromagnetic and muonic components. It allows an accurate determination of the spread of primary masses in the cosmic-ray flux. Up till now, constraints on the spread of primary masses have been dominated by systematic uncertainties. The present correlation measurement is not affected by systematics in the measurement of the depth of shower maximum or the signal in the water Cherenkov stations. The analysis relies on general characteristics of air showers and is thus robust also with respect to uncertainties in hadronic event generators. The observed correlation in the energy range around the `ankle' at lg(E/eV)=18.519.0\lg(E/{\rm eV})=18.5-19.0 differs significantly from expectations for pure primary cosmic-ray compositions. A light composition made up of proton and helium only is equally inconsistent with observations. The data are explained well by a mixed composition including nuclei with mass A>4A > 4. Scenarios such as the proton dip model, with almost pure compositions, are thus disfavoured as the sole explanation of the ultrahigh-energy cosmic-ray flux at Earth.Comment: Published version. Added journal reference and DOI. Added Report Numbe

    Spread of a SARS-CoV-2 variant through Europe in the summer of 2020.

    Get PDF
    Following its emergence in late 2019, the spread of SARS-CoV-21,2 has been tracked by phylogenetic analysis of viral genome sequences in unprecedented detail3–5. Although the virus spread globally in early 2020 before borders closed, intercontinental travel has since been greatly reduced. However, travel within Europe resumed in the summer of 2020. Here we report on a SARS-CoV-2 variant, 20E (EU1), that was identified in Spain in early summer 2020 and subsequently spread across Europe. We find no evidence that this variant has increased transmissibility, but instead demonstrate how rising incidence in Spain, resumption of travel, and lack of effective screening and containment may explain the variant’s success. Despite travel restrictions, we estimate that 20E (EU1) was introduced hundreds of times to European countries by summertime travellers, which is likely to have undermined local efforts to minimize infection with SARS-CoV-2. Our results illustrate how a variant can rapidly become dominant even in the absence of a substantial transmission advantage in favourable epidemiological settings. Genomic surveillance is critical for understanding how travel can affect transmission of SARS-CoV-2, and thus for informing future containment strategies as travel resumes. © 2021, The Author(s), under exclusive licence to Springer Nature Limited

    Anisotropic flow of charged hadrons, pions and (anti-)protons measured at high transverse momentum in Pb-Pb collisions at sNN=2.76\sqrt{s_{\rm NN}}=2.76 TeV

    Get PDF
    The elliptic, v2v_2, triangular, v3v_3, and quadrangular, v4v_4, azimuthal anisotropic flow coefficients are measured for unidentified charged particles, pions and (anti-)protons in Pb-Pb collisions at sNN=2.76\sqrt{s_{\rm NN}} = 2.76 TeV with the ALICE detector at the Large Hadron Collider. Results obtained with the event plane and four-particle cumulant methods are reported for the pseudo-rapidity range η<0.8|\eta|<0.8 at different collision centralities and as a function of transverse momentum, pTp_{\rm T}, out to pT=20p_{\rm T}=20 GeV/cc. The observed non-zero elliptic and triangular flow depends only weakly on transverse momentum for pT>8p_{\rm T}>8 GeV/cc. The small pTp_{\rm T} dependence of the difference between elliptic flow results obtained from the event plane and four-particle cumulant methods suggests a common origin of flow fluctuations up to pT=8p_{\rm T}=8 GeV/cc. The magnitude of the (anti-)proton elliptic and triangular flow is larger than that of pions out to at least pT=8p_{\rm T}=8 GeV/cc indicating that the particle type dependence persists out to high pTp_{\rm T}.Comment: 16 pages, 5 captioned figures, authors from page 11, published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/186

    Centrality dependence of charged particle production at large transverse momentum in Pb-Pb collisions at sNN=2.76\sqrt{s_{\rm{NN}}} = 2.76 TeV

    Get PDF
    The inclusive transverse momentum (pTp_{\rm T}) distributions of primary charged particles are measured in the pseudo-rapidity range η<0.8|\eta|<0.8 as a function of event centrality in Pb-Pb collisions at sNN=2.76\sqrt{s_{\rm{NN}}}=2.76 TeV with ALICE at the LHC. The data are presented in the pTp_{\rm T} range 0.15<pT<500.15<p_{\rm T}<50 GeV/cc for nine centrality intervals from 70-80% to 0-5%. The Pb-Pb spectra are presented in terms of the nuclear modification factor RAAR_{\rm{AA}} using a pp reference spectrum measured at the same collision energy. We observe that the suppression of high-pTp_{\rm T} particles strongly depends on event centrality. In central collisions (0-5%) the yield is most suppressed with RAA0.13R_{\rm{AA}}\approx0.13 at pT=6p_{\rm T}=6-7 GeV/cc. Above pT=7p_{\rm T}=7 GeV/cc, there is a significant rise in the nuclear modification factor, which reaches RAA0.4R_{\rm{AA}} \approx0.4 for pT>30p_{\rm T}>30 GeV/cc. In peripheral collisions (70-80%), the suppression is weaker with RAA0.7R_{\rm{AA}} \approx 0.7 almost independently of pTp_{\rm T}. The measured nuclear modification factors are compared to other measurements and model calculations.Comment: 17 pages, 4 captioned figures, 2 tables, authors from page 12, published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/284

    Measurement of charm production at central rapidity in proton-proton collisions at s=2.76\sqrt{s} = 2.76 TeV

    Get PDF
    The pTp_{\rm T}-differential production cross sections of the prompt (B feed-down subtracted) charmed mesons D0^0, D+^+, and D+^{*+} in the rapidity range y<0.5|y|<0.5, and for transverse momentum 1<pT<121< p_{\rm T} <12 GeV/cc, were measured in proton-proton collisions at s=2.76\sqrt{s} = 2.76 TeV with the ALICE detector at the Large Hadron Collider. The analysis exploited the hadronic decays D0^0 \rightarrow Kπ\pi, D+^+ \rightarrow Kππ\pi\pi, D+^{*+} \rightarrow D0π^0\pi, and their charge conjugates, and was performed on a Lint=1.1L_{\rm int} = 1.1 nb1^{-1} event sample collected in 2011 with a minimum-bias trigger. The total charm production cross section at s=2.76\sqrt{s} = 2.76 TeV and at 7 TeV was evaluated by extrapolating to the full phase space the pTp_{\rm T}-differential production cross sections at s=2.76\sqrt{s} = 2.76 TeV and our previous measurements at s=7\sqrt{s} = 7 TeV. The results were compared to existing measurements and to perturbative-QCD calculations. The fraction of cdbar D mesons produced in a vector state was also determined.Comment: 20 pages, 5 captioned figures, 4 tables, authors from page 15, published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/307
    corecore