155 research outputs found

    Sr_14Cu_24O_41Sr\_{14}Cu\_{24}O\_{41} : a complete model for the chain sub-system

    Full text link
    A second neighbor tJ+Vt-J+V model for the chain subsystem of the Sr_14Cu_24O_41Sr\_{14}Cu\_{24}O\_{41} has been extracted from ab-initio calculations. This model does not use periodic approximation but describes the entire chain through the use of the four-dimensional crystallographic description. Second neighbors interactions are found to be of same order than the first neighbors ones. The computed values of the second neighbors magnetic interaction are coherent with experimental estimations of the intra-dimer magnetic interactions, even if slightly smaller. The reasons of this underestimation are detailed. The computed model allowed us to understand the origin of the chain dimerisation and predicts correctly the relative occurrence of dimers and free spins. The orbitals respectively supporting the magnetic electrons and the holes have been found to be essentially supported by the copper 3d orbitals (spins) and the surrounding oxygen 2p2p orbitals (holes), thus giving a strong footing to the existence of Zhang-Rice singlets

    Generalized parton distributions of the pion in a Bethe-Salpeter approach

    Get PDF
    We calculate generalized parton distribution functions in a field theoretic formalism using a covariant Bethe-Salpeter approach for the determination of the bound-state wave function. We describe the procedure in an exact calculation in scalar Electrodynamics proving that the relevant corrections outside our scheme vanish. We extend the formalism to the Nambu--Jona-Lasinio model, a realistic theory of the pion. We go in both cases beyond all previous calculations and discover that all important features required by general physical considerations, like symmetry properties, sum rules and the polynomiality condition, are explicitly verified. We perform a numerical study of their behavior in the weak and strong coupling limits.Comment: 19 pages, 21 eps figures, accepted for publication in EPJ

    Tubular cell and keratinocyte single-cell transcriptomics applied to lupus nephritis reveal type I IFN and fibrosis relevant pathways

    Get PDF
    © 2019, The Author(s), under exclusive licence to Springer Nature America, Inc. The molecular and cellular processes that lead to renal damage and to the heterogeneity of lupus nephritis (LN) are not well understood. We applied single-cell RNA sequencing (scRNA-seq) to renal biopsies from patients with LN and evaluated skin biopsies as a potential source of diagnostic and prognostic markers of renal disease. Type I interferon (IFN)-response signatures in tubular cells and keratinocytes distinguished patients with LN from healthy control subjects. Moreover, a high IFN-response signature and fibrotic signature in tubular cells were each associated with failure to respond to treatment. Analysis of tubular cells from patients with proliferative, membranous and mixed LN indicated pathways relevant to inflammation and fibrosis, which offer insight into their histologic differences. In summary, we applied scRNA-seq to LN to deconstruct its heterogeneity and identify novel targets for personalized approaches to therapy

    The Hydrogel Endovascular Aneurysm Treatment Trial (HEAT): A Randomized Controlled Trial of the Second-Generation Hydrogel Coil

    Get PDF
    © 2020 Congress of Neurological Surgeons 2020. BACKGROUND: Aneurysm recurrence after coiling has been associated with aneurysm growth, (re)hemorrhage, and a greater need for follow-up. The second-generation HydroCoil Embolic System (HES; MicroVention, Inc) consists of a platinum core with integrated hydrogel and was developed to reduce recurrence through enhancing packing density and healing within the aneurysm. OBJECTIVE: To compare recurrence between the second-generation HES and bare platinum coil (BPC) in the new-generation Hydrogel Endovascular Aneurysm Treatment Trial (HEAT). METHODS: HEAT is a randomized, controlled trial that enrolled subjects with ruptured or unruptured 3- to 14-mm intracranial aneurysms amenable to coiling. The primary endpoint was aneurysm recurrence using the Raymond-Roy scale. Secondary endpoints included minor and major recurrence, packing density, adverse events related to the procedure and/or device, mortality, initial complete occlusion, aneurysm retreatment, hemorrhage from target aneurysm during follow-up, aneurysm occlusion stability, and clinical outcome at final follow-up. RESULTS: A total of 600 patients were randomized (HES, n = 297 and BPC, n = 303), including 28% with ruptured aneurysms. Recurrence occurred in 11 (4.4%) subjects in the HES arm and 44 (15.4%) subjects in the BPC arm (P =. 002). While the initial occlusion rate was higher with BPC, the packing density and both major and minor recurrence rates were in favor of HES. Secondary endpoints including adverse events, retreatment, hemorrhage, mortality, and clinical outcome did not differ between arms. CONCLUSION: Coiling of small-to-medium aneurysms with second-generation HES resulted in less recurrence when compared to BPC, without increased harm. These data further support the use of the second-generation HES for the embolization of intracranial aneurysms. Video Abstract: 10.1093/neuros/nyaa006 nyaa006Media1 613226478400

    Elliptic flow of charged particles in Pb-Pb collisions at 2.76 TeV

    Get PDF
    We report the first measurement of charged particle elliptic flow in Pb-Pb collisions at 2.76 TeV with the ALICE detector at the CERN Large Hadron Collider. The measurement is performed in the central pseudorapidity region (|η\eta|<0.8) and transverse momentum range 0.2< pTp_{\rm T}< 5.0 GeV/cc. The elliptic flow signal v2_2, measured using the 4-particle correlation method, averaged over transverse momentum and pseudorapidity is 0.087 ±\pm 0.002 (stat) ±\pm 0.004 (syst) in the 40-50% centrality class. The differential elliptic flow v2(pT)_2(p_{\rm T}) reaches a maximum of 0.2 near pTp_{\rm T} = 3 GeV/cc. Compared to RHIC Au-Au collisions at 200 GeV, the elliptic flow increases by about 30%. Some hydrodynamic model predictions which include viscous corrections are in agreement with the observed increase.Comment: 10 pages, 4 captioned figures, published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/389

    The ALICE Transition Radiation Detector: Construction, operation, and performance

    Get PDF
    The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this paper the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p-Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection. (c) 2017 CERN for the benefit of the Authors. Published by Elsevier B.V

    Physics of the HL-LHC, and Perspectives at the HE-LHC

    Get PDF

    Higher harmonic anisotropic flow measurements of charged particles in Pb-Pb collisions at 2.76 TeV

    Get PDF
    We report on the first measurement of the triangular v3v_3, quadrangular v4v_4, and pentagonal v5v_5 charged particle flow in Pb-Pb collisions at 2.76 TeV measured with the ALICE detector at the CERN Large Hadron Collider. We show that the triangular flow can be described in terms of the initial spatial anisotropy and its fluctuations, which provides strong constraints on its origin. In the most central events, where the elliptic flow v2v_2 and v3v_3 have similar magnitude, a double peaked structure in the two-particle azimuthal correlations is observed, which is often interpreted as a Mach cone response to fast partons. We show that this structure can be naturally explained from the measured anisotropic flow Fourier coefficients.Comment: 10 pages, 4 figures, published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/387

    Measurement of D+- and D0 production in deep inelastic scattering using a lifetime tag at HERA

    Get PDF
    The production of D-+/-- and D-0-mesons has been measured with the ZEUS detector at HERA using an integrated luminosity of 133.6 pb(-1). The measurements cover the kinematic range 5 < Q(2) < 1000 GeV2, 0.02 < y < 0.7, 1.5 < p(T)(D) < 15 GeV and |eta(D)| < 1.6. Combinatorial background to the D-meson signals is reduced by using the ZEUS microvertex detector to reconstruct displaced secondary vertices. Production cross sections are compared with the predictions of next-to-leading-order QCD, which is found to describe the data well. Measurements are extrapolated to the full kinematic phase space in order to obtain the open-charm contribution, F-2(c (c) over bar), to the proton structure function, F-2
    corecore