410 research outputs found

    Mechanical ventilation: lessons from the ARDSNet trial

    Get PDF
    The acute respiratory distress syndrome (ARDS) is an inflammatory disease of the lungs characterized clinically by bilateral pulmonary infiltrates, decreased pulmonary compliance and hypoxemia. Although supportive care for ARDS seems to have improved over the past few decades, few studies have shown that any treatment can decrease mortality for this deadly syndrome. In the 4 May 2000 issue of New England Journal of Medicine, the results of an NIH-sponsored trial were presented; they demonstrated that the use of a ventilatory strategy that minimizes ventilator-induced lung injury leads to a 22% decrease in mortality. The implications of this study with respect to clinical practice, further ARDS studies and clinical research in the critical care setting are discussed

    Perceived barriers for treatment of chronic heart failure in general practice; are they affecting performance?

    Get PDF
    BACKGROUND: The aim of this study is to determine to what extent barriers perceived by general practitioners (GPs) for prescribing angiotensin-converting enzyme inhibitors (ACE-I) in chronic heart failure (CHF) patients are related to underuse and underdosing of these drugs in actual practice. METHODS: Barriers were assessed with a semi-structured questionnaire. Prescribing data were extracted from GPs' computerised medical records for a random sample of their CHF patients. Relations between barriers and prescribing behaviour were assessed by means of Spearman rank correlation and multivariate regression modelling. RESULTS: GPs prescribed ACE-I to 45% of their patients and had previously initiated such treatment in an additional 3.5%, in an average standardised dose of 13.5 mg. They perceived a median of four barriers in prescribing ACE-I or optimising ACE-I dose. Many GPs found it difficult to change treatment initiated by a cardiologist. Furthermore, initiating ACE-I in patients already using a diuretic or stable on their current medication was perceived as barrier. Titrating the ACE-I dose was seen as difficult by more than half of the GPs. No significant relationships could be found between the barriers perceived and actual ACE-I prescribing. Regarding ACE-I dosing, the few GPs who did not agree that the ACE-I should be as high as possible prescribed higher ACE-I doses. CONCLUSION: Variation between GPs in prescribing ACE-I for CHF cannot be explained by differences in the barriers they perceive. Tailor-made interventions targeting only those doctors that perceive a specific barrier will therefore not be an efficient approach to improve quality of care

    High frequency oscillatory ventilation and prone positioning in a porcine model of lavage-induced acute lung injury

    Get PDF
    BACKGROUND: This animal study was conducted to assess the combined effects of high frequency oscillatory ventilation (HFOV) and prone positioning on pulmonary gas exchange and hemodynamics. METHODS: Saline lung lavage was performed in 14 healthy pigs (54 ± 3.1 kg, mean ± SD) until the arterial oxygen partial pressure (PaO(2)) decreased to 55 ± 7 mmHg. The animals were ventilated in the pressure controlled mode (PCV) with a positive endexpiratory pressure (PEEP) of 5 cmH(2)O and a tidal volume (V(T)) of 6 ml/kg body weight. After a stabilisation period of 60 minutes, the animals were randomly assigned to 2 groups. Group 1: HFOV in supine position; group 2: HFOV in prone position. After evaluation of prone positioning in group 2, the mean airway pressure (P(mean)) was increased by 3 cmH(2)O from 16 to 34 cmH(2)O every 20 minutes in both groups accompanied by measurements of respiratory and hemodynamic variables. Finally all animals were ventilated supine with PCV, PEEP = 5 cm H(2)O, V(T )= 6 ml/kg. RESULTS: Combination of HFOV with prone positioning improves oxygenation and results in normalisation of cardiac output and considerable reduction of pulmonary shunt fraction at a significant (p < 0.05) lower P(mean )than HFOV and supine positioning. CONCLUSION: If ventilator induced lung injury is ameliorated by a lower P(mean), a combined treatment approach using HFOV and prone positioning might result in further lung protection

    Reasons of general practitioners for not prescribing lipid-lowering medication to patients with diabetes: a qualitative study

    Get PDF
    Background: Lipid-lowering medication remains underused, even in high-risk populations. The objective of this study was to determine factors underlying general practitioners' decisions not to prescribe such drugs to patients with type 2 diabetes. Methods: A qualitative study with semi-structured interviews using real cases was conducted to explore reasons for not prescribing lipid-lowering medication after a guideline was distributed that recommended the use of statins in most patients with type 2 diabetes. Seven interviews were conducted with general practitioners (GPs) in The Netherlands, and analysed using an analytic inductive approach. Results: Reasons for not-prescribing could be divided into patient and physician-attributed factors. According to the GPs, some patients do not follow-up on agreed medication and others object to taking lipid-lowering medication, partly for legitimate reasons such as expected or perceived side effects. Furthermore, the GPs themselves perceived reservations for prescribing lipid-lowering medication in patients with short life expectancy, expected compliance problems or near goal lipid levels. GPs sometimes postponed the start of treatment because of other priorities. Finally, barriers were seen in the GPs' practice organisation, and at the primary-secondary care interface. Conclusion: Some of the barriers mentioned by GPs seem to be valid reasons, showing that guideline non-adherence can be quite rational. On the other hand, treatment quality could improve by addressing issues, such as lack of knowledge or motivation of both the patient and the GP. More structured management in general practice may also lead to better treatment

    Metabolic acidosis may be as protective as hypercapnic acidosis in an ex-vivo model of severe ventilator-induced lung injury: a pilot study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>There is mounting experimental evidence that hypercapnic acidosis protects against lung injury. However, it is unclear if acidosis <it>per se </it>rather than hypercapnia is responsible for this beneficial effect. Therefore, we sought to evaluate the effects of hypercapnic (respiratory) versus normocapnic (metabolic) acidosis in an ex vivo model of ventilator-induced lung injury (VILI).</p> <p>Methods</p> <p>Sixty New Zealand white rabbit ventilated and perfused heart-lung preparations were used. Six study groups were evaluated. Respiratory acidosis (RA), metabolic acidosis (MA) and normocapnic-normoxic (Control - C) groups were randomized into high and low peak inspiratory pressures, respectively. Each preparation was ventilated for 1 hour according to a standardized ventilation protocol. Lung injury was evaluated by means of pulmonary edema formation (weight gain), changes in ultrafiltration coefficient, mean pulmonary artery pressure changes as well as histological alterations.</p> <p>Results</p> <p>HPC group gained significantly greater weight than HPMA, HPRA and all three LP groups (P = 0.024), while no difference was observed between HPMA and HPRA groups regarding weight gain. Neither group differ on ultrafiltration coefficient. HPMA group experienced greater increase in the mean pulmonary artery pressure at 20 min (P = 0.0276) and 40 min (P = 0.0012) compared with all other groups. Histology scores were significantly greater in HP vs. LP groups (p < 0.001).</p> <p>Conclusions</p> <p>In our experimental VILI model both metabolic acidosis and hypercapnic acidosis attenuated VILI-induced pulmonary edema implying a mechanism other than possible synergistic effects of acidosis with CO2 for VILI attenuation.</p

    Observation of associated near-side and away-side long-range correlations in √sNN=5.02  TeV proton-lead collisions with the ATLAS detector

    Get PDF
    Two-particle correlations in relative azimuthal angle (Δϕ) and pseudorapidity (Δη) are measured in √sNN=5.02  TeV p+Pb collisions using the ATLAS detector at the LHC. The measurements are performed using approximately 1  μb-1 of data as a function of transverse momentum (pT) and the transverse energy (ΣETPb) summed over 3.1<η<4.9 in the direction of the Pb beam. The correlation function, constructed from charged particles, exhibits a long-range (2<|Δη|<5) “near-side” (Δϕ∼0) correlation that grows rapidly with increasing ΣETPb. A long-range “away-side” (Δϕ∼π) correlation, obtained by subtracting the expected contributions from recoiling dijets and other sources estimated using events with small ΣETPb, is found to match the near-side correlation in magnitude, shape (in Δη and Δϕ) and ΣETPb dependence. The resultant Δϕ correlation is approximately symmetric about π/2, and is consistent with a dominant cos⁡2Δϕ modulation for all ΣETPb ranges and particle pT

    Measurement of the cross-section of high transverse momentum vector bosons reconstructed as single jets and studies of jet substructure in pp collisions at √s = 7 TeV with the ATLAS detector

    Get PDF
    This paper presents a measurement of the cross-section for high transverse momentum W and Z bosons produced in pp collisions and decaying to all-hadronic final states. The data used in the analysis were recorded by the ATLAS detector at the CERN Large Hadron Collider at a centre-of-mass energy of √s = 7 TeV;{\rm Te}{\rm V}andcorrespondtoanintegratedluminosityof and correspond to an integrated luminosity of 4.6\;{\rm f}{{{\rm b}}^{-1}}.ThemeasurementisperformedbyreconstructingtheboostedWorZbosonsinsinglejets.ThereconstructedjetmassisusedtoidentifytheWandZbosons,andajetsubstructuremethodbasedonenergyclusterinformationinthejetcentreofmassframeisusedtosuppressthelargemultijetbackground.ThecrosssectionforeventswithahadronicallydecayingWorZboson,withtransversemomentum. The measurement is performed by reconstructing the boosted W or Z bosons in single jets. The reconstructed jet mass is used to identify the W and Z bosons, and a jet substructure method based on energy cluster information in the jet centre-of-mass frame is used to suppress the large multi-jet background. The cross-section for events with a hadronically decaying W or Z boson, with transverse momentum {{p}_{{\rm T}}}\gt 320\;{\rm Ge}{\rm V}andpseudorapidity and pseudorapidity |\eta |\lt 1.9,ismeasuredtobe, is measured to be {{\sigma }_{W+Z}}=8.5\pm 1.7$ pb and is compared to next-to-leading-order calculations. The selected events are further used to study jet grooming techniques

    Climate-induced phenology shifts linked to range expansions in species with multiple reproductive cycles per year

    Get PDF
    Advances in phenology (the annual timing of species’ life-cycles) in response to climate change are generally viewed as bioindicators of climate change, but have not been considered as predictors of range expansions. Here, we show that phenology advances combine with the number of reproductive cycles per year (voltinism) to shape abundance and distribution trends in 130 species of British Lepidoptera, in response to ~0.5 °C spring-temperature warming between 1995 and 2014. Early adult emergence in warm years resulted in increased within- and between-year population growth for species with multiple reproductive cycles per year (n = 39 multivoltine species). By contrast, early emergence had neutral or negative consequences for species with a single annual reproductive cycle (n = 91 univoltine species), depending on habitat specialisation. We conclude that phenology advances facilitate polewards range expansions in species exhibiting plasticity for both phenology and voltinism, but may inhibit expansion by less flexible species

    Search for the neutral Higgs bosons of the minimal supersymmetric standard model in pp collisions at root s=7 TeV with the ATLAS detector

    Get PDF
    A search for neutral Higgs bosons of the Minimal Supersymmetric Standard Model (MSSM) is reported. The analysis is based on a sample of proton-proton collisions at a centre-of-mass energy of 7TeV recorded with the ATLAS detector at the Large Hadron Collider. The data were recorded in 2011 and correspond to an integrated luminosity of 4.7 fb-1 to 4.8 fb-1. Higgs boson decays into oppositely-charged muon or τ lepton pairs are considered for final states requiring either the presence or absence of b-jets. No statistically significant excess over the expected background is observed and exclusion limits at the 95% confidence level are derived. The exclusion limits are for the production cross-section of a generic neutral Higgs boson, φ, as a function of the Higgs boson mass and for h/A/H production in the MSSM as a function of the parameters mA and tan β in the mhmax scenario for mA in the range of 90GeV to 500 GeV. Copyright CERN
    corecore