2,189 research outputs found
VIM-positive Pseudomonas aeruginosa in a large tertiary care hospital: Matched case-control studies and a network analysis
Background: Emergence of multidrug-resistant Pseudomonas aeruginosa is of global concern. We aimed to identify epidemiological relationships, the most common way of transmission, and risk factors for presence of Verona Integron-encoded Metallo-ÎČ-lactamase (VIM)-positive P. aeruginosa (VIM-PA). Methods: We conducted a network analysis and matched case-control studies (1:2:2). Controls were hospital-based and matched with cases for ward, day of admission (control group 1 and 2) and time between admission and the identification of VIM-PA (control group 1). The network was visualized using Cytoscape, an
Effect of novel endoscope cleaning brush on duodenoscope contamination
Background and aims:Current duodenoscope reprocessing protocols are insufficient to prevent contamination and require adaptations to prevent endoscopy-associated infections (EAI). This study aimed to investigate the effect of a new endoscope cleaning brush on the contamination rate of ready-to-use duodenoscopes. Methods:This retrospective before-and-after intervention study collected duodenoscope surveillance culture results from March 2018 to June 2022. Contamination was defined as â„1 colony-forming units of gastrointestinal or oral microorganisms (MGO). In December 2020, an endoscope cleaning brush with a sweeper design was introduced as the intervention in the manual cleaning of duodenoscopes. A logistic mixed effects model was used to study the effects of the intervention. Results:Data were collected from 176 culture sets before the new brush's introduction and 81 culture sets after. Pre-introduction, culture sets positive with MGO comprised 45.5% (95% CI: 38.3%-52.8%, 80/176), decreasing to 17.3% (95% CI: 10.6%-26.9%, 14/81) after implementing the new brush. Compared to the former brush, duodenoscopes cleaned with the new brush had lower odds of contamination with MGO (aOR=0.25, 95% CI: 0.11-0.58, p=0.001).Conclusions:Use of the new brush in manual cleaning reduced contamination with MGO and is expected to prevent EAIs. These findings should be confirmed in future prospective randomized studies.</p
Serological markers for prediction of response to anti-tumor necrosis factor treatment in Crohn's disease
peer reviewedOBJECTIVES: The use of monoclonal anti-tumor necrosis factor (TNF) antibodies (infliximab, Remicade) is a new therapeutic approach for severe refractory luminal or fistulizing, Crohn's disease (CD). However, up to 30% of patients do not respond to this treatment. So far, no parameters predictive of response to anti-TNT have been identified. Our aim was to determine whether serological markers ASCA (anti-Saccharomyces cerevisiae antibodies) or pANCA (perinuclear antineutrophil cytoplasmic antibodies) could identify Crohn's patients likely to benefit from anti-TNF therapy. METHODS: Serum samples of 279 CID patients were analyzed for ASCA and pANCA before anti-TNF therapy. A blinded physician determined clinical response at week 4 (refractory luminal CD) or week 10 (fistulizing CD) after the first infusion of infliximab (5 mg/kg). RESULTS: Overall, there was no relationship between ASCA or pANCA and response to therapy. However, lower response rates were observed for patients with refractory intestinal disease carrying the pANCA+/ASCA- combination, although this lacked significance (p = 0.067). CONCLUSIONS: In this cohort of infliximab-treated patients, neither ASCA nor pANCA could predict response to treatment. However, the combination pANCA+/ASCA- might warrant further investigation for its value in predicting nonresponse in patients with refractory luminal disease
Establishment and characterization of an infectious cDNA clone of a classical swine fever virus LOM strain
Classical swine fever virus (CSFV) causes a highly contagious disease among swine that has an important economic impact worldwide. CSFV strain LOM is an attenuated virus of low virulent strain of Miyagi isolated from Japan in 1956. Eight DNA fragments representing the genome of the CSFV strain LOM were obtained by RT-PCR. These were used to determine the complete nucleotide sequence and construct a full-length cDNA clone which was called Flc-LOM. Sequence analysis of the recombinant clone (Flc-LOM) revealed the presence of eight mutations, resulting in two amino acid substitutions, when compared to the parental sequence. RNA transcripts of both LOM and Flc-LOM were directly infectious in PK-15 cells. The rescued Flc-LOM virus grew more slowly than the parental virus, LOM, in the cells. Intramuscular immunization with Flc-LOM was safe and highly immunogenic in pigs; no clinical signs or virus transmission to sentinel animals were observed after 35 days. CSFV-specific neutralizing antibodies were detected 14 days post-infection. After challenge with the virulent CSFV strain SW03, pigs immunized with Flc-LOM were shown to be fully protected. Thus, our newly established infectious clone of CSFV, Flc-LOM, could serve as a vaccine candidate
High prevalence rate of digestive tract bacteria in duodenoscopes: A nationwide study
Objective Increasing numbers of outbreaks caused by contaminated duodenoscopes used for Endoscopic Retrograde Cholangiopancreatography (ERCP) procedures have been reported, some with fatal outcomes. We conducted a nationwide cross-sectional study to determine the prevalence of bacterial contamination of reprocessed duodenoscopes in The Netherlands. Design All 73 Dutch ERCP centres were invited to sample â„2 duodenoscopes using centrally distributed kits according to uniform sampling methods, explained by video instructions. Depending on duodenoscope type, four to six sites were sampled and centrally cultured. Contamination was defined as (1) any microorganism with â„20 colony forming units (CFU)/20 mL (AM20) and (2) presence of microorganisms with gastrointestinal or oral origin, independent of CFU count (MGO). Results Sixty-seven out of 73 centres (92%) sampled 745 sites of 155 duodenoscopes. Ten different duodenoscope types from three distinct manufacturers were sampled including 69 (46%) Olympus TJF-Q180V, 43 (29%) Olympus TJF-160VR, 11 (7%) Pentax ED34-i10T, 8 (5%) Pentax ED-3490TK and 5 (3%) Fujifilm ED-530XT8. Thirty-three (22%) duodenoscopes from 26 (39%) centres were contaminated (AM20). On 23 (15%) duodenoscopes MGO were detected, including Enterobacter cloacae, Escherichia coli, Klebsiella pneumonia and yeasts. For both definitions, contamination was not duodenoscope type dependent (p values: 0.20 and higher). Conclusion In 39% of all Dutch ERCP centres, at least one AM20-contaminated patient-ready duodenoscope was identified. Fifteen per cent of the duodenoscopes harboured MGO, indicating residual organic material of previous patients, that is, failing of disinfection. These results suggest that the present reprocessing and process control procedures are not adequate and safe
Ethnic differences in total and HDL cholesterol among Turkish, Moroccan and Dutch ethnic groups living in Amsterdam, the Netherlands.
<p>Abstract</p> <p>Background</p> <p>High total cholesterol and low HDL (high-density lipoprotein) cholesterol are important determinants of cardiovascular disease. Little is known about dyslipidemia among Turkish and Moroccan migrants, two of the largest ethnic minority groups in several European countries. This study examines ethnic differences in total and HDL cholesterol levels between Dutch, Turkish and Moroccan ethnic groups.</p> <p>Methods</p> <p>Data were collected in the setting of a general health survey, in Amsterdam, the Netherlands, in 2004. Total response rate was 45% (Dutch: 46%, Turks: 50%, Moroccans: 39%). From 1,220 adults information on history of hypercholesterolemia, lifestyle and demographic background was obtained via health interviews. In a physical examination measurements of anthropometry and blood pressure were performed and blood was collected. Total and HDL cholesterol were determined in serum.</p> <p>Results</p> <p>Total cholesterol levels were lower and hypercholesterolemia was less prevalent among the Moroccan and Turkish than the Dutch ethnic population. HDL cholesterol was also relatively low among these migrant groups. The resulting total/HDL cholesterol ratio was particularly unfavourable among the Turkish ethnic group. Controlling for Body Mass Index and alcohol abstinence substantially attenuated ethnic differences in HDL cholesterol levels and total/HDL cholesterol ratio.</p> <p>Conclusions</p> <p>Total cholesterol levels are relatively low in Turkish and Moroccan migrants. However part of this advantage is off-set by their relatively low levels of HDL cholesterol, resulting in an unfavourable total/HDL cholesterol ratio, particularly in the Turkish population. Important factors in explaining ethnic differences are the relatively high Body Mass Index and level of alcohol abstinence in these migrant groups.</p
Observation of associated near-side and away-side long-range correlations in âsNN=5.02ââTeV proton-lead collisions with the ATLAS detector
Two-particle correlations in relative azimuthal angle (ÎÏ) and pseudorapidity (Îη) are measured in âsNN=5.02ââTeV p+Pb collisions using the ATLAS detector at the LHC. The measurements are performed using approximately 1ââÎŒb-1 of data as a function of transverse momentum (pT) and the transverse energy (ÎŁETPb) summed over 3.1<η<4.9 in the direction of the Pb beam. The correlation function, constructed from charged particles, exhibits a long-range (2<|Îη|<5) ânear-sideâ (ÎÏâŒ0) correlation that grows rapidly with increasing ÎŁETPb. A long-range âaway-sideâ (ÎÏâŒÏ) correlation, obtained by subtracting the expected contributions from recoiling dijets and other sources estimated using events with small ÎŁETPb, is found to match the near-side correlation in magnitude, shape (in Îη and ÎÏ) and ÎŁETPb dependence. The resultant ÎÏ correlation is approximately symmetric about Ï/2, and is consistent with a dominant cosâĄ2ÎÏ modulation for all ÎŁETPb ranges and particle pT
Measurement of the cross-section of high transverse momentum vector bosons reconstructed as single jets and studies of jet substructure in pp collisions at âs = 7 TeV with the ATLAS detector
This paper presents a measurement of the cross-section for high transverse momentum W and Z bosons produced in pp collisions and decaying to all-hadronic final states. The data used in the analysis were recorded by the ATLAS detector at the CERN Large Hadron Collider at a centre-of-mass energy of âs = 7 TeV;{\rm Te}{\rm V}4.6\;{\rm f}{{{\rm b}}^{-1}}{{p}_{{\rm T}}}\gt 320\;{\rm Ge}{\rm V}|\eta |\lt 1.9{{\sigma }_{W+Z}}=8.5\pm 1.7$ pb and is compared to next-to-leading-order calculations. The selected events are further used to study jet grooming techniques
Search for high-mass resonances decaying to dilepton final states in pp collisions at sâ=7 TeV with the ATLAS detector
The ATLAS detector at the Large Hadron Collider is used to search for high-mass resonances decaying to an electron-positron pair or a muon-antimuon pair. The search is sensitive to heavy neutral ZâČ gauge bosons, Randall-Sundrum gravitons, Z * bosons, techni-mesons, Kaluza-Klein Z/Îł bosons, and bosons predicted by Torsion models. Results are presented based on an analysis of pp collisions at a center-of-mass energy of 7 TeV corresponding to an integrated luminosity of 4.9 fbâ1 in the e + e â channel and 5.0 fbâ1 in the ÎŒ + ÎŒ âchannel. A Z âČ boson with Standard Model-like couplings is excluded at 95 % confidence level for masses below 2.22 TeV. A Randall-Sundrum graviton with coupling k/MPl=0.1 is excluded at 95 % confidence level for masses below 2.16 TeV. Limits on the other models are also presented, including Technicolor and Minimal ZâČ Models
- âŠ