1,890 research outputs found

    Screening and assessment tools for gaming disorder: A comprehensive systematic review

    Get PDF
    The inclusion of gaming disorder (GD) as an official diagnosis in the ICD-11 was a significant milestone for the field. However, the optimal measurement approaches for GD are currently unclear. This comprehensive systematic review aimed to identify and evaluate all available English-language GD tools and their corresponding evidence. A search of PsychINFO, PsychArticles, ScienceDirect, Scopus, Web of Science, and Google Scholar identified 32 tools employed in 320 studies (N = 462,249 participants). The evaluation framework examined tools in relation to: (1) conceptual and practical considerations; (2) alignment with DSM-5 and ICD-11 criteria; (3) type and quantity of studies and samples; and (4) psychometric properties. The evaluation showed that GD instrumentation has proliferated, with 2.5 tools, on average, published annually since 2013. Coverage of DSM-5 and ICD-11 criteria was inconsistent, especially for the criterion of continued use despite harm. Tools converge on the importance of screening for impaired control over gaming and functional impairment. Overall, no single tool was found to be clearly superior, but the AICA-Sgaming, GAS-7, IGDT-10, IGDS9-SF, and Lemmens IGD-9 scales had greater evidential support for their psychometric properties. The GD field would benefit from a standard international tool to identify gaming-related harms across the spectrum of maladaptive gaming behaviors.Peer reviewedFinal Accepted Versio

    The ground state of Sr3Ru2O7 revisited; Fermi liquid close to a ferromagnetic instability

    Full text link
    We show that single-crystalline Sr3Ru2O7 grown by a floating-zone technique is an isotropic paramagnet and a quasi-two dimensional metal as spin-triplet superconducting Sr2RuO4 is. The ground state is Fermi liquid with very low residual resistivity (3 micro ohm cm for in-plane currents) and a nearly ferromagnetic metal with the largest Wilson ratio Rw>10 among paramagnets so far. This contrasts with the ferromagnetic order at Tc=104 K reported on single crystals grown by a flux method [Cao et al., Phys. Rev. B 55, R672 (1997)]. We have also found a dramatic changeover from paramagnetism to ferromagnetism under applied pressure. This suggests the existence of a substantial ferromagnetic instability on the verge of a quantum phase transition in the Fermi liquid state.Comment: 5 pages, 4 figures, to be published in Phys. Rev. B : Rapid co

    Ischemia monitoring in off-pump coronary artery bypass surgery using intravascular near-infrared spectroscopy

    Get PDF
    BACKGROUND: In off-pump coronary artery bypass surgery, manipulations on the beating heart can lead to transient interruptions of myocardial oxygen supply, which can generate an accumulation of oxygen-dependent metabolites in coronary venous blood. The objective of this study was to evaluate the reliability of intravascular near-infrared spectroscopy as a monitoring method to detect possible ischemic events in off-pump coronary artery bypass procedures. METHODS: In 15 elective patients undergoing off-pump myocardial revascularization, intravascular near-infrared spectroscopic analysis of coronary venous blood was performed. NIR signals were transferred through a fiberoptic catheter for signal emission and collection. For data analysis and processing, a miniature spectrophotometer with multivariate statistical package was used. Signal acquisition and analysis were performed before and after revascularization. Spectroscopic data were compared with hemodynamic parameters, electrocardiogram, transesophageal echocardiography and laboratory findings. RESULTS: A conversion to extracorporeal circulation was not necessary. The mean number of grafts per patient was 3.1 Âą 0.6. An intraoperative myocardial ischemia was not evident, as indicated by electrocardiogram and transesophageal echocardiography. Continuous spectroscopic analysis showed reproducible absorption spectra of coronary sinus blood. Due to uneventful intraoperative courses, clear ischemia-related changes could be detected in none of the patients. CONCLUSION: Our initial results show that intravascular near-infrared spectroscopy can reliably be used for an online intraoperative ischemia monitoring in off-pump coronary artery bypass surgery. However, the method has to be further evaluated and standardized to determine the role of spectroscopy in off-pump coronary artery bypass surgery

    TGA2 signaling in response to reactive electrophile species is not dependent on cysteine modification of TGA2

    Get PDF
    This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.Reactive electrophile species (RES), including prostaglandins, phytoprostanes and 12-oxo phytodienoic acid (OPDA), activate detoxification responses in plants and animals. However, the pathways leading to the activation of defense reactions related to abiotic or biotic stress as a function of RES formation, accumulation or treatment are poorly understood in plants. Here, the thiol-modification of proteins, including the RES-activated basic region/leucine zipper transcription factor TGA2, was studied. TGA2 contains a single cysteine residue (Cys186) that was covalently modified by reactive cyclopentenones but not required for induction of detoxification genes in response to OPDA or prostaglandin A1. Activation of the glutathione-S-transferase 6 (GST6) promoter was responsive to cyclopentenones but not to unreactive cyclopentanones, including jasmonic acid suggesting that thiol reactivity of RES is important to activate the TGA2-dependent signaling pathway resulting in GST6 activation We show that RES modify thiols in numerous proteins in vivo, however, thiol reactivity alone appears not to be sufficient for biological activity as demonstrated by the failure of several membrane permeable thiol reactive reagents to activate the GST6 promoter.Peer reviewedFinal Published versio

    PageMan: An interactive ontology tool to generate, display, and annotate overview graphs for profiling experiments

    Get PDF
    BACKGROUND: Microarray technology has become a widely accepted and standardized tool in biology. The first microarray data analysis programs were developed to support pair-wise comparison. However, as microarray experiments have become more routine, large scale experiments have become more common, which investigate multiple time points or sets of mutants or transgenics. To extract biological information from such high-throughput expression data, it is necessary to develop efficient analytical platforms, which combine manually curated gene ontologies with efficient visualization and navigation tools. Currently, most tools focus on a few limited biological aspects, rather than offering a holistic, integrated analysis. RESULTS: Here we introduce PageMan, a multiplatform, user-friendly, and stand-alone software tool that annotates, investigates, and condenses high-throughput microarray data in the context of functional ontologies. It includes a GUI tool to transform different ontologies into a suitable format, enabling the user to compare and choose between different ontologies. It is equipped with several statistical modules for data analysis, including over-representation analysis and Wilcoxon statistical testing. Results are exported in a graphical format for direct use, or for further editing in graphics programs. PageMan provides a fast overview of single treatments, allows genome-level responses to be compared across several microarray experiments covering, for example, stress responses at multiple time points. This aids in searching for trait-specific changes in pathways using mutants or transgenics, analyzing development time-courses, and comparison between species. In a case study, we analyze the results of publicly available microarrays of multiple cold stress experiments using PageMan, and compare the results to a previously published meta-analysis. PageMan offers a complete user's guide, a web-based over-representation analysis as well as a tutorial, and is freely available at . CONCLUSION: PageMan allows multiple microarray experiments to be efficiently condensed into a single page graphical display. The flexible interface allows data to be quickly and easily visualized, facilitating comparisons within experiments and to published experiments, thus enabling researchers to gain a rapid overview of the biological responses in the experiments

    Measurements of neutrino oscillation in appearance and disappearance channels by the T2K experiment with 6.6 x 10(20) protons on target

    Get PDF
    111 pages, 45 figures, submitted to Physical Review D. Minor revisions to text following referee comments111 pages, 45 figures, submitted to Physical Review D. Minor revisions to text following referee comments111 pages, 45 figures, submitted to Physical Review D. Minor revisions to text following referee commentsWe thank the J-PARC staff for superb accelerator performance and the CERN NA61/SHINE Collaboration for providing valuable particle production data. We acknowledge the support of MEXT, Japan; NSERC, NRC, and CFI, Canada; CEA and CNRS/IN2P3, France; DFG, Germany; INFN, Italy; National Science Centre (NCN), Poland; RSF, RFBR and MES, Russia; MINECO and ERDF funds, Spain; SNSF and SER, Switzerland; STFC, UK; and the U. S. Deparment of Energy, USA. We also thank CERN for the UA1/NOMAD magnet, DESY for the HERA-B magnet mover system, NII for SINET4, the WestGrid and SciNet consortia in Compute Canada, GridPP, UK, and the Emerald High Performance Computing facility in the Centre for Innovation, UK. In addition, participation of individual researchers and institutions has been further supported by funds from ERC (FP7), EU; JSPS, Japan; Royal Society, UK; and DOE Early Career program, USA

    Measurement of the electron neutrino charged-current interaction rate on water with the T2K ND280 pi(0) detector

    Get PDF
    10 pages, 6 figures, Submitted to PRDhttp://journals.aps.org/prd/abstract/10.1103/PhysRevD.91.112010Š 2015 American Physical Society11 pages, 6 figures, as accepted to PRD11 pages, 6 figures, as accepted to PRD11 pages, 6 figures, as accepted to PR

    All-cause and liver-related mortality risk factors in excessive drinkers: Analysis of data from the UK biobank

    Get PDF
    Background: High alcohol intake is associated with increased mortality. We aimed to identify factors affecting mortality in people drinking extreme amounts of alcohol. Methods: We obtained information from the UK Biobank on approximately 500,000 participants aged 40–70 years at baseline assessment in 2006–2010. Habitual alcohol intake, lifestyle and physiological data, laboratory test results, and hospital diagnoses and death certificate data (to June 2020) for 5136 men (2.20% of male participants) and 1504 women (0.60%) who reported consuming ≥80 or ≥50 g/day, respectively, were used in survival analysis. Results: Mortality hazard ratios for these excessive drinkers, compared to all other participants, were 2.02 (95% CI 1.89–2.17) for all causes, 1.89 (1.69–2.12) for any cancer, 1.87 (1.61–2.17) for any circulatory disease, and 9.40 (7.00–12.64) for any liver disease. Liver disease diagnosis or abnormal liver function tests predicted not only deaths attributed to liver disease but also those from cancers or circulatory diseases. Mortality among excessive drinkers was also associated with quantitative alcohol intake; diagnosed alcohol dependence, harmful use, or withdrawal syndrome; and current smoking at assessment. Conclusions: People with chronic excessive alcohol intake experience decreased average survival, but there is substantial variation in their mortality, with liver abnormality and alcohol dependence or other alcohol use disorders associated with a worse prognosis. Clinically, patients with these risk factors and high alcohol intake should be considered for early or intensive management. Research can usefully focus on the factors predisposing to dependence or liver abnormality

    Measurement of the cross-section of high transverse momentum vector bosons reconstructed as single jets and studies of jet substructure in pp collisions at √s = 7 TeV with the ATLAS detector

    Get PDF
    This paper presents a measurement of the cross-section for high transverse momentum W and Z bosons produced in pp collisions and decaying to all-hadronic final states. The data used in the analysis were recorded by the ATLAS detector at the CERN Large Hadron Collider at a centre-of-mass energy of √s = 7 TeV;{\rm Te}{\rm V}andcorrespondtoanintegratedluminosityof and correspond to an integrated luminosity of 4.6\;{\rm f}{{{\rm b}}^{-1}}.ThemeasurementisperformedbyreconstructingtheboostedWorZbosonsinsinglejets.ThereconstructedjetmassisusedtoidentifytheWandZbosons,andajetsubstructuremethodbasedonenergyclusterinformationinthejetcentre−of−massframeisusedtosuppressthelargemulti−jetbackground.Thecross−sectionforeventswithahadronicallydecayingWorZboson,withtransversemomentum. The measurement is performed by reconstructing the boosted W or Z bosons in single jets. The reconstructed jet mass is used to identify the W and Z bosons, and a jet substructure method based on energy cluster information in the jet centre-of-mass frame is used to suppress the large multi-jet background. The cross-section for events with a hadronically decaying W or Z boson, with transverse momentum {{p}_{{\rm T}}}\gt 320\;{\rm Ge}{\rm V}andpseudorapidity and pseudorapidity |\eta |\lt 1.9,ismeasuredtobe, is measured to be {{\sigma }_{W+Z}}=8.5\pm 1.7$ pb and is compared to next-to-leading-order calculations. The selected events are further used to study jet grooming techniques

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
    • …
    corecore