29 research outputs found

    Electroluminescence TPCs at the thermal diffusion limit

    Get PDF
    [EN] The NEXT experiment aims at searching for the hypothetical neutrinoless double-beta decay from the 136Xe isotope using a high-purity xenon TPC. Efficient discrimination of the events through pattern recognition of the topology of primary ionisation tracks is a major requirement for the experiment. However, it is limited by the diffusion of electrons. It is known that the addition of a small fraction of a molecular gas to xenon reduces electron diffusion. On the other hand, the electroluminescence (EL) yield drops and the achievable energy resolution may be compromised. We have studied the effect of adding several molecular gases to xenon (CO2, CH4 and CF4) on the EL yield and energy resolution obtained in a small prototype of driftless gas proportional scintillation counter. We have compared our results on the scintillation characteristics (EL yield and energy resolution) with a microscopic simulation, obtaining the diffusion coefficients in those conditions as well. Accordingly, electron diffusion may be reduced from about 10 mm/ sqrt(¿) for pure xenon down to 2.5 mm/sqrt(m) using additive concentrations of about 0.05%, 0.2% and 0.02% for CO2, CH4 and CF4, respectively. Our results show that CF4 admixtures present the highest EL yield in those conditions, but very poor energy resolution as a result of huge fluctuations observed in the EL formation. CH4 presents the best energy resolution despite the EL yield being the lowest. The results obtained with xenon admixtures are extrapolated to the operational conditions of the NEXT-100 TPC. CO2 and CH4 show potential as molecular additives in a large xenon TPC. While CO2 has some operational constraints, making it difficult to be used in a large TPC, CH4 shows the best performance and stability as molecular additive to be used in the NEXT-100 TPC, with an extrapolated energy resolution of 0.4% at 2.45 MeV for concentrations below 0.4%, which is only slightly worse than the one obtained for pure xenon. We demonstrate the possibility to have an electroluminescence TPC operating very close to the thermal diffusion limit without jeopardizing the TPC performance, if CO2 or CH4 are chosen as additives.The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad of Spain under grants FIS2014-53371-C04, the Severo Ochoa Program SEV-2014-0398 and the Maria de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/105921/2014, SFRH/BPD/109180/2015 and SFRH/BPD/76842/2011; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-AC02-06CH11357 (Argonne National Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0017721 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC-2015-18820. We also warmly acknowledge the Laboratori Nazionali del Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.Henriques, CAO.; Monteiro, CMB.; Gonzalez-Diaz, D.; Azevedo, CDR.; Freitas, EDC.; Mano, RDP.; Jorge, MR.... (2019). Electroluminescence TPCs at the thermal diffusion limit. Journal of High Energy Physics (Online). 1:1-20. https://doi.org/10.1007/JHEP01(2019)027S1201NEXT collaboration, J. Martín-Albo et al., Sensitivity of NEXT-100 to neutrinoless double beta decay, JHEP 05 (2016) 159 [ arXiv:1511.09246 ] [ INSPIRE ].T. Brunner et al., An RF-only ion-funnel for extraction from high-pressure gases, Intern. J. Mass Spectrom. 379 (2015) 110 [ INSPIRE ].PANDAX-III collaboration, J. Galan, Microbulk MicrOMEGAs for the search of 0νββ of 136 Xe in the PandaX-III experiment, 2016 JINST 11 P04024 [ arXiv:1512.09034 ] [ INSPIRE ].D. Yu. Akimov, A.A. Burenkov, V.F. Kuzichev, V.L. Morgunov and V.N. Solovev, Low background experiments with high pressure gas scintillation proportional detector, physics/9704021 [ INSPIRE ].Yu. M. Gavrilyuk et al., A technique for searching for the 2K capture in 124 Xe with a copper proportional counter, Phys. Atom. Nucl. 78 (2015) 1563 [ INSPIRE ].D.R. Nygren, Columnar recombination: a tool for nuclear recoil directional sensitivity in a xenon-based direct detection WIMP search, J. Phys. Conf. Ser. 460 (2013) 012006 [ INSPIRE ].XENON collaboration, E. Aprile et al., First Dark Matter Search Results from the XENON1T Experiment, Phys. Rev. Lett. 119 (2017) 181301 [ arXiv:1705.06655 ] [ INSPIRE ].XENON100 collaboration, E. Aprile et al., Dark Matter Results from 225 Live Days of XENON100 Data, Phys. Rev. Lett. 109 (2012) 181301 [ arXiv:1207.5988 ] [ INSPIRE ].LUX collaboration, D.S. Akerib et al., Results from a search for dark matter in the complete LUX exposure, Phys. Rev. Lett. 118 (2017) 021303 [ arXiv:1608.07648 ] [ INSPIRE ].PandaX-II collaboration, X. Cui et al., Dark Matter Results From 54-Ton-Day Exposure of PandaX-II Experiment, Phys. Rev. Lett. 119 (2017) 181302 [ arXiv:1708.06917 ] [ INSPIRE ].EXO collaboration, J.B. Albert et al., Search for Neutrinoless Double-Beta Decay with the Upgraded EXO-200 Detector, Phys. Rev. Lett. 120 (2018) 072701 [ arXiv:1707.08707 ] [ INSPIRE ].KamLAND-Zen collaboration, A. Gando et al., Search for Majorana Neutrinos near the Inverted Mass Hierarchy Region with KamLAND-Zen, Phys. Rev. Lett. 117 (2016) 082503 [ arXiv:1605.02889 ] [ INSPIRE ].XMASS collaboration, K. Abe et al., Search for two-neutrino double electron capture on 124 Xe with the XMASS-I detector, Phys. Lett. B 759 (2016) 64 [ arXiv:1510.00754 ] [ INSPIRE ].XENON collaboration, E. Aprile et al., Search for two-neutrino double electron capture of 124 Xe with XENON100, Phys. Rev. C 95 (2017) 024605 [ arXiv:1609.03354 ] [ INSPIRE ].R. Lüscher et al., Search for ββ decay in 136 Xe: new results from the Gotthard experiment, Phys. Lett. B 434 (1998) 407 [ INSPIRE ].NEXT collaboration, P. Ferrario et al., First proof of topological signature in the high pressure xenon gas TPC with electroluminescence amplification for the NEXT experiment, JHEP 01 (2016) 104 [ arXiv:1507.05902 ] [ INSPIRE ].NEXT collaboration, D. Lorca et al., Characterisation of NEXT-DEMO using xenon K α X-rays, 2014 JINST 9 P10007 [ arXiv:1407.3966 ] [ INSPIRE ].NEXT collaboration, D. González-Díaz et al., Accurate γ and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atm, Nucl. Instrum. Meth. A 804 (2015) 8 [ arXiv:1504.03678 ] [ INSPIRE ].C.M.B. Monteiro et al., Secondary Scintillation Yield in Pure Xenon, 2007 JINST 2 P05001 [ physics/0702142 ] [ INSPIRE ].C.M.B. Monteiro, J.A.M. Lopes, J.F. C.A. Veloso and J.M.F. dos Santos, Secondary scintillation yield in pure argon, Phys. Lett. B 668 (2008) 167 [ INSPIRE ].E.D.C. Freitas et al., Secondary scintillation yield in high-pressure xenon gas for neutrinoless double beta decay (0νββ) search, Phys. Lett. B 684 (2010) 205 [ INSPIRE ].C.M.B. Monteiro et al., Secondary scintillation yield from gaseous micropattern electron multipliers in direct dark matter detection, Phys. Lett. B 677 (2009) 133 [ INSPIRE ].C.M.B. Monteiro, L.M.P. Fernandes, J.F. C.A. Veloso, C.A.B. Oliveira and J.M.F. dos Santos, Secondary scintillation yield from GEM and THGEM gaseous electron multipliers for direct dark matter search, Phys. Lett. B 714 (2012) 18 [ INSPIRE ].C. Balan et al., MicrOMEGAs operation in high pressure xenon: Charge and scintillation readout, 2011 JINST 6 P02006 [ arXiv:1009.2960 ] [ INSPIRE ].J.M.F. dos Santos et al., Development of portable gas proportional scintillation counters for x-ray spectrometry, X-Ray Spectrom. 30 (2001) 373.NEXT collaboration, J. Renner et al., Background rejection in NEXT using deep neural networks, 2017 JINST 12 T01004 [ arXiv:1609.06202 ] [ INSPIRE ].T. Himi et al., Emission spectra from Ar-Xe, Ar-Kr, Ar-N2, Ar-CH4, Ar-CO2 and Xe-N2 gas proportional scintillation counters, Nucl. Instrum. Meth. 205 (1983) 591.C.D.R. Azevedo et al., An homeopathic cure to pure Xenon large diffusion, 2016 JINST 11 C02007 [ arXiv:1511.07189 ] [ INSPIRE ].NEXT collaboration, C.A.O. Henriques et al., Secondary scintillation yield of xenon with sub-percent levels of CO 2 additive for rare-event detection, Phys. Lett. B 773 (2017) 663 [ arXiv:1704.01623 ] [ INSPIRE ].P.C.P.S. Simões, J.M.F. dos Santos and C.A.N. Conde, Driftless gas proportional scintillation counter pulse analysis using digital processing techniques, X Ray Spectrom. 30 (2001) 342.P.C.P.S. Simões et al., A new method for pulse analysis of driftless-gas proportional scintillation counters, Nucl. Instrum. Meth. A 505 (2003) 247.C.D.R. Azevedo et al., Microscopic simulation of xenon-based optical TPCs in the presence of molecular additives, Nucl. Instrum. Meth. A 877 (2018) 157 [ arXiv:1705.09481 ] [ INSPIRE ].L.M.P. Fernandes et al., Primary and secondary scintillation measurements in a xenon Gas Proportional Scintillation Counter, 2010 JINST 5 P09006 [Erratum ibid. 5 (2010) A12001] [ arXiv:1009.2719 ] [ INSPIRE ].C.M.B. Monteiro et al., An argon gas proportional scintillation counter with UV avalanche photodiode scintillation readout, IEEE Trans. Nucl. Sci. 48 (2001) 1081.J.A.M. Lopes et al., A xenon gas proportional scintillation counter with a UV-sensitive large-area avalanche photodiode, IEEE Trans. Nucl. Sci. 48 (2001) 312.D.F. Anderson et al., A large area gas scintillation proportional counter, Nucl. Instrum. Meth. 163 (1979) 125.Z. Kowalski et al., Fano factor implications from gas scintillation proportional counter measurements, Nucl. Instrum. Meth. A 279 (1989) 567.S.J.C. do Carmo et al., Experimental study of the ω-values and Fano factors of gaseous xenon and Ar-Xe mixtures for X-rays, IEEE Trans. Nucl. Sci. 55 (2008) 2637.http://magboltz.web.cern.ch/magboltz/ (accessed 14.11.2016).T.H.V.T. Dias et al., Full-energy absorption of x-ray energies near the Xe L- and K-photoionization thresholds in xenon gas detectors: Simulation and experimental results, J. Appl. Phys. 82 (1997) 2742.D. Nygren, High-pressure xenon gas electroluminescent TPC for 0νββ-decay search, Nucl. Instrum. Meth. A 603 (2009) 337 [ INSPIRE ].NEXT collaboration, V. Álvarez et al., The NEXT-100 experiment for neutrinoless double beta decay searches (Conceptual Design Report), arXiv:1106.3630 [ INSPIRE ].NEXT collaboration, V. Álvarez et al., Operation and first results of the NEXT-DEMO prototype using a silicon photomultiplier tracking array, 2013 JINST 8 P09011 [ arXiv:1306.0471 ] [ INSPIRE ]

    Effects of PI and PIII Snake Venom Haemorrhagic Metalloproteinases on the Microvasculature: A Confocal Microscopy Study on the Mouse Cremaster Muscle

    Get PDF
    The precise mechanisms by which Snake Venom Metalloproteinases (SVMPs) disrupt the microvasculature and cause haemorrhage have not been completely elucidated, and novel in vivo models are needed. In the present study, we compared the effects induced by BaP1, a PI SVMP isolated from Bothrops asper venom, and CsH1, a PIII SVMP from Crotalus simus venom, on cremaster muscle microvasculature by topical application of the toxins on isolated tissue (i.e., ex vivo model), and by intra-scrotal administration of the toxins (i.e., in vivo model). The whole tissue was fixed and immunostained to visualize the three components of blood vessels by confocal microscopy. In the ex vivo model, BaP1 was able to degrade type IV collagen and laminin from the BM of microvessels. Moreover, both SVMPs degraded type IV collagen from the BM in capillaries to a higher extent than in PCV and arterioles. CsH1 had a stronger effect on type IV collagen than BaP1. In the in vivo model, the effect of BaP1 on type IV collagen was widespread to the BM of arterioles and PCV. On the other hand, BaP1 was able to disrupt the endothelial barrier in PCV and to increase vascular permeability. Moreover, this toxin increased the size of gaps between pericytes in PCV and created new gaps between smooth muscle cells in arterioles in ex vivo conditions. These effects were not observed in the case of CsH1. In conclusion, our findings demonstrate that both SVMPs degrade type IV collagen from the BM in capillaries in vivo. Moreover, while the action of CsH1 is more directed to the BM of microvessels, the effects of BaP1 are widespread to other microvascular components. This study provides new insights in the mechanism of haemorrhage and other pathological effects induced by these toxins

    Measuring the health-related Sustainable Development Goals in 188 countries : a baseline analysis from the Global Burden of Disease Study 2015

    Get PDF
    Background In September, 2015, the UN General Assembly established the Sustainable Development Goals (SDGs). The SDGs specify 17 universal goals, 169 targets, and 230 indicators leading up to 2030. We provide an analysis of 33 health-related SDG indicators based on the Global Burden of Diseases, Injuries, and Risk Factors Study 2015 (GBD 2015). Methods We applied statistical methods to systematically compiled data to estimate the performance of 33 health-related SDG indicators for 188 countries from 1990 to 2015. We rescaled each indicator on a scale from 0 (worst observed value between 1990 and 2015) to 100 (best observed). Indices representing all 33 health-related SDG indicators (health-related SDG index), health-related SDG indicators included in the Millennium Development Goals (MDG index), and health-related indicators not included in the MDGs (non-MDG index) were computed as the geometric mean of the rescaled indicators by SDG target. We used spline regressions to examine the relations between the Socio-demographic Index (SDI, a summary measure based on average income per person, educational attainment, and total fertility rate) and each of the health-related SDG indicators and indices. Findings In 2015, the median health-related SDG index was 59.3 (95% uncertainty interval 56.8-61.8) and varied widely by country, ranging from 85.5 (84.2-86.5) in Iceland to 20.4 (15.4-24.9) in Central African Republic. SDI was a good predictor of the health-related SDG index (r(2) = 0.88) and the MDG index (r(2) = 0.2), whereas the non-MDG index had a weaker relation with SDI (r(2) = 0.79). Between 2000 and 2015, the health-related SDG index improved by a median of 7.9 (IQR 5.0-10.4), and gains on the MDG index (a median change of 10.0 [6.7-13.1]) exceeded that of the non-MDG index (a median change of 5.5 [2.1-8.9]). Since 2000, pronounced progress occurred for indicators such as met need with modern contraception, under-5 mortality, and neonatal mortality, as well as the indicator for universal health coverage tracer interventions. Moderate improvements were found for indicators such as HIV and tuberculosis incidence, minimal changes for hepatitis B incidence took place, and childhood overweight considerably worsened. Interpretation GBD provides an independent, comparable avenue for monitoring progress towards the health-related SDGs. Our analysis not only highlights the importance of income, education, and fertility as drivers of health improvement but also emphasises that investments in these areas alone will not be sufficient. Although considerable progress on the health-related MDG indicators has been made, these gains will need to be sustained and, in many cases, accelerated to achieve the ambitious SDG targets. The minimal improvement in or worsening of health-related indicators beyond the MDGs highlight the need for additional resources to effectively address the expanded scope of the health-related SDGs.Peer reviewe

    Health variables and gill morphology in the tropical fish Astyanax fasciatus from a sewage-contaminated river

    No full text
    The relative condition factor (Kn), gonadosomatic index (GSI), selected hematological variables and gill morphology of the fish Astyanax fasciatus were analyzed in two sites (site I was unpolluted and site 2 was polluted with untreated domestic sewage) of a tropical river (Camanducaia river, São Paulo State, Brazil). The relationship between the body mass (M-B) and the standard length (L-S) of A. fasciatus from both sites was M-B = 0.00799 L-S(3.51843). Tyhe Kn values from both the males and females were significantly higher in site 2. The mean corpuscular hemoglobin and mean corpuscular hemoglobin concentration were higher in females from site 2. Gill tissue anomalies and gill parasites were rare in fish from both sites; however, the number of chloride cells was significantly higher in fish from site 1. A. fasciatus presents high capacity to live in ion-poor and soft water and is able to compensate for environmental changes caused by untreated domestic sewage discharges. (c) 2004 Elsevier B.V. All rights reserved
    corecore