51 research outputs found

    Study of hadronic event-shape variables in multijet final states in pp collisions at √s=7 TeV

    Get PDF
    Peer reviewe

    Searches for electroweak production of charginos, neutralinos, and sleptons decaying to leptons and W, Z, and Higgs bosons in pp collisions at 8 TeV

    Get PDF
    Peer reviewe

    Measurement of prompt J/ψ pair production in pp collisions at √s = 7 Tev

    Get PDF
    Peer reviewe

    Constraints on parton distribution functions and extraction of the strong coupling constant from the inclusive jet cross section in pp collisions at √s=7 TeV

    Get PDF
    Peer reviewe

    Pooled analysis of WHO Surgical Safety Checklist use and mortality after emergency laparotomy

    Get PDF
    Background The World Health Organization (WHO) Surgical Safety Checklist has fostered safe practice for 10 years, yet its place in emergency surgery has not been assessed on a global scale. The aim of this study was to evaluate reported checklist use in emergency settings and examine the relationship with perioperative mortality in patients who had emergency laparotomy. Methods In two multinational cohort studies, adults undergoing emergency laparotomy were compared with those having elective gastrointestinal surgery. Relationships between reported checklist use and mortality were determined using multivariable logistic regression and bootstrapped simulation. Results Of 12 296 patients included from 76 countries, 4843 underwent emergency laparotomy. After adjusting for patient and disease factors, checklist use before emergency laparotomy was more common in countries with a high Human Development Index (HDI) (2455 of 2741, 89.6 per cent) compared with that in countries with a middle (753 of 1242, 60.6 per cent; odds ratio (OR) 0.17, 95 per cent c.i. 0.14 to 0.21, P <0001) or low (363 of 860, 422 per cent; OR 008, 007 to 010, P <0.001) HDI. Checklist use was less common in elective surgery than for emergency laparotomy in high-HDI countries (risk difference -94 (95 per cent c.i. -11.9 to -6.9) per cent; P <0001), but the relationship was reversed in low-HDI countries (+121 (+7.0 to +173) per cent; P <0001). In multivariable models, checklist use was associated with a lower 30-day perioperative mortality (OR 0.60, 0.50 to 073; P <0.001). The greatest absolute benefit was seen for emergency surgery in low- and middle-HDI countries. Conclusion Checklist use in emergency laparotomy was associated with a significantly lower perioperative mortality rate. Checklist use in low-HDI countries was half that in high-HDI countries.Peer reviewe

    Global variation in anastomosis and end colostomy formation following left-sided colorectal resection

    Get PDF
    Background End colostomy rates following colorectal resection vary across institutions in high-income settings, being influenced by patient, disease, surgeon and system factors. This study aimed to assess global variation in end colostomy rates after left-sided colorectal resection. Methods This study comprised an analysis of GlobalSurg-1 and -2 international, prospective, observational cohort studies (2014, 2016), including consecutive adult patients undergoing elective or emergency left-sided colorectal resection within discrete 2-week windows. Countries were grouped into high-, middle- and low-income tertiles according to the United Nations Human Development Index (HDI). Factors associated with colostomy formation versus primary anastomosis were explored using a multilevel, multivariable logistic regression model. Results In total, 1635 patients from 242 hospitals in 57 countries undergoing left-sided colorectal resection were included: 113 (6·9 per cent) from low-HDI, 254 (15·5 per cent) from middle-HDI and 1268 (77·6 per cent) from high-HDI countries. There was a higher proportion of patients with perforated disease (57·5, 40·9 and 35·4 per cent; P < 0·001) and subsequent use of end colostomy (52·2, 24·8 and 18·9 per cent; P < 0·001) in low- compared with middle- and high-HDI settings. The association with colostomy use in low-HDI settings persisted (odds ratio (OR) 3·20, 95 per cent c.i. 1·35 to 7·57; P = 0·008) after risk adjustment for malignant disease (OR 2·34, 1·65 to 3·32; P < 0·001), emergency surgery (OR 4·08, 2·73 to 6·10; P < 0·001), time to operation at least 48 h (OR 1·99, 1·28 to 3·09; P = 0·002) and disease perforation (OR 4·00, 2·81 to 5·69; P < 0·001). Conclusion Global differences existed in the proportion of patients receiving end stomas after left-sided colorectal resection based on income, which went beyond case mix alone

    Intracerebral clysis in a rat glioma model

    No full text
    OBJECTIVE: Intracerebral clysis (ICC) is a new term we use to describe convection-enhanced microinfusion into the brain. This study establishes baseline parameters for preclinical, in vivo, drug investigations using ICC in a rat glioma model. METHODS: Intracranial pressure was measured, with an intraparenchymal fiber-optic catheter, in male Fischer rats 10, 15, 20, and 25 days after implantation of C6 glioma cells in the right frontal lobe (n = 80) and in control rats without tumor (n = 20), before and during ICC. A 25% albumin solution (100 μl) was infused through an intratumoral catheter at 0.5, 1.0, 2.0, 3.0, and 4.0 μl/min. Infusate distribution was assessed by infusion of fluorescein isothiocyanate-dextran (M(r) 20,000), using the aforementioned parameters (n = 36). Brains were sectioned and photographed under ultraviolet light, and distribution was calculated by computer analysis (NIH Image for Macintosh). Safe effective drug distribution was demonstrated by measuring tumor sizes and apoptosis in animals treated with N,N'-bis(2- chloroethyl)-N-nitrosourea via ICC, compared with untreated controls. Magnetic resonance imaging noninvasively confirmed tumor growth before treatment. RESULTS: Intracranial pressure increased with tumor progression, from 5.5 mm Hg at baseline to 12.95 mm Hg on Day 25 after tumor cell implantation. Intracranial pressure during ICC ranged from 5 to 21 mm Hg and was correlated with increasing infusion volumes and increasing rates of infusion. No toxicity was observed, except at the higher ends of the tumor size and volume ranges. Fluorescein isothiocyanate-dextran distribution was greater with larger infusion volumes (30 μl versus 10 μl, n = 8, P<0.05). No significant differences in distribution were observed when different infusion rates were compared while the volume was kept constant. At tolerated flow rates, the volumes of distribution were sufficient to promote adequate drug delivery to tumors. N,N'-Bis(2-chloroethyl)-N-nitrosourea treatment resulted in significant decreases in tumor size, compared with untreated controls. CONCLUSION: The C6 glioma model can be easily modified to study aspects of interstitial delivery via ICC and the application of ICC to the screening of potential antitumor agents for safety and efficacy.link_to_subscribed_fulltex
    corecore