158 research outputs found
3D Printing and Engineering Tools Relevant to Plan a Transcatheter Procedure
Advance cardiac imaging techniques such as three-dimensional (3D) printing technology and engineering tools have experienced a rapid development over the last decade in many surgical and interventional settings. In presence of complex cardiac and extra-cardiac anatomies, the creation of a physical, patient-specific model is useful to better understand the anatomical spatial relationships and formulate the best surgical or interventional plan. Although many case reports and small series have been published over this topic, at the present time, there is still a lack of strong scientific evidence of the benefit of 3D models and advance engineering tools, including virtual and augmented reality, in clinical practice and only qualitative evaluation of the models has been used to investigate their clinical use. Patient-specific 3D models can be printed in many different materials including rigid, flexible and transparent materials, depending on their application. To plan interventional procedure, transparent materials may be preferred in order to better evaluate the device or stent landing zone. 3D models can also be used as an input for augmented and virtual reality application and advance fluido-dynamic simulation, which aim to support the interventional cardiologist before entering the cath lab. The aim of this chapter is to present an overview on how 3D printing, extended reality platforms and the most common computational engineering methodologies"finite element and computational fluid dynamics"are currently used to support percutaneous procedures in congenital heart disease (CHD), with examples from the scientific literature
Blood flow characteristics after aortic valve neocuspidization in paediatric patients: a comparison with the Ross procedure.
AIMS: The aortic valve (AV) neocuspidization (Ozaki procedure) is a novel surgical technique for AV disease that preserves the natural motion and cardiodynamics of the aortic root. In this study, we sought to evaluate, by 4D-flow magnetic resonance imaging, the aortic blood flow characteristics after AV neocuspidization in paediatric patients. METHODS AND RESULTS: Aortic root and ascending aorta haemodynamics were evaluated in a population of patients treated with the Ozaki procedure; results were compared with those of a group of patients operated with the Ross technique. Cardiovascular magnetic resonance studies were performed at 1.5 T using a 4D flow-sensitive sequence acquired with retrospective electrocardiogram-gating and respiratory navigator. Post-processing of 4D-flow analysis was performed to calculate flow eccentricity and wall shear stress. Twenty children were included in this study, 10 after Ozaki and 10 after Ross procedure. Median age at surgery was 10.7 years (range 3.9-16.5 years). No significant differences were observed in wall shear stress values measured at the level of the proximal ascending aorta between the two groups. The analysis of flow patterns showed no clear association between eccentric flow and the procedure performed. The Ozaki group showed just a slightly increased transvalvular maximum velocity. CONCLUSION: Proximal aorta flow dynamics of children treated with the Ozaki and the Ross procedure are comparable. Similarly to the Ross, Ozaki technique restores a physiological laminar flow pattern in the short-term follow-up, with the advantage of not inducing a bivalvular disease, although further studies are warranted to evaluate its long-term results
A workflow for patient-specific fluid-structure interaction analysis of the mitral valve: A proof of concept on a mitral regurgitation case
The mechanics of the mitral valve (MV) are the result of the interaction of different anatomical structures complexly arranged within the left heart (LH), with the blood flow. MV structure abnormalities might cause valve regurgitation which in turn can lead to heart failure. Patient-specific computational models of the MV could provide a personalised understanding of MV mechanics, dysfunctions and possible interventions. In this study, we propose a semi-automatic pipeline for MV modelling based on the integration of state-of-the-art medical imaging, i.e. cardiac magnetic resonance (CMR) and 3D transoesophageal-echocardiogram (TOE) with fluid-structure interaction (FSI) simulations. An FSI model of a patient with MV regurgitation was implemented using the finite element (FE) method and smoothed particle hydrodynamics (SPH). Our study showed the feasibility of combining image information and computer simulations to reproduce patient-specific MV mechanics as seen on medical images, and the potential for efficient in-silico studies of MV disease, personalised treatments and device design
Three-dimensional printing in congenital heart disease: Considerations on training and clinical implementation from a teaching session
In light of growing interest for three-dimensional printing technology in the cardiovascular community, this study focused on exploring the possibilities of providing training for cardiovascular three-dimensional printing in the context of a relevant international congress and providing considerations on the delivery of such courses. As a second objective, the study sought to capture preferences in relation to three-dimensional printing uses and set-ups from those attending the training session. A survey was administered to n = 30 professionals involved or interested in three-dimensional printing cardiovascular models following a specialised teaching session. Survey results suggest the potential for split training sessions, with a broader introduction for those with no prior experience in three-dimensional printing followed by a more in-depth and hands-on session. All participants agreed on the potential of the technology in all its applications, particularly for aiding decision-making around complex surgical or interventional cases. When exploring setting up an in-house three-dimensional printing service, the majority of participants reported that their centre was already equipped with an in-house facility or expressed a desire that such a facility should be available, with a minority preferring consigning models to an external third party for printing
Beyond apical ballooning: computational modelling reveals morphological features of Takotsubo cardiomyopathy
Takotsubo cardiomyopathy (TCM) is characterized by transient myocardial dysfunction, typically at the left ventricular (LV) apex. Its pathophysiology and recovery mechanisms remain unknown. We investigated LV morphology and deformation in n = 28 TCM patients. Patients with MRI within 5 days from admission ("early TCM") showed reduced LVEF and higher ventricular volumes, but no differences in ECG, global strains or myocardial oedema. Statistical shape modelling described LV size (Mode 1), apical sphericity (Mode 2) and height (Mode 3). Significant differences in Mode 1 suggest that "early TCM" LV remodeling is mainly influenced by a change in ventricular size rather than apical sphericity
Effective Rheology of Bubbles Moving in a Capillary Tube
We calculate the average volumetric flux versus pressure drop of bubbles
moving in a single capillary tube with varying diameter, finding a square-root
relation from mapping the flow equations onto that of a driven overdamped
pendulum. The calculation is based on a derivation of the equation of motion of
a bubble train from considering the capillary forces and the entropy production
associated with the viscous flow. We also calculate the configurational
probability of the positions of the bubbles.Comment: 4 pages, 1 figur
Disability and satisfaction after Rotator Cuff decompression or repair: a sex and gender analysis
<p>Abstract</p> <p>Background</p> <p>Rotator-cuff pathology is the most common cause of pain and disability in the shoulder. Examining the combined effect of biological and societal factors on disability would potentially identify existing differences between men and women with rotator cuff pathology which would help to provide suggestions for better models of care. Purpose of this study was to determine the overall differences in disability between men and women and to examine the relationship between factors that represent sex (biological factors) and gender (non-biological factors) with disability and satisfaction with surgical outcome 6 months after rotator cuff surgery.</p> <p>Methods</p> <p>Patients with impingement syndrome and/or rotator cuff tear who underwent rotator cuff surgery completed the Western Ontario Rotator Cuff (WORC) index, the American Shoulder & Elbow Surgeons (ASES) assessment form, and the Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) outcome measures prior to surgery and 6 months post-operatively. They also rated their satisfaction with surgery at their follow-up appointment.</p> <p>Results and Discussion</p> <p>One hundred and seventy patients entered into the study (85 men and 85 women). One hundred and sixty patients (94%) completed the 6-month assessment. Women reported more disability both prior to and after surgery. Disability at 6 months was associated with pain-limited range of motion, participation limitation, age and strength. Satisfaction with surgery was associated with level of reported disability, expectations for improved pain, pain-limited range of motion and strength.</p> <p>Conclusions</p> <p>The results of this study indicate that women with rotator cuff pathology suffer from higher levels of pre- and post-operative disability and sex and gender qualities contribute to these differences. Gender-sensitive approach will help to identify existing differences between men and women which will help to promote more effective and tailored care by health professionals.</p
Multi-messenger observations of a binary neutron star merger
On 2017 August 17 a binary neutron star coalescence candidate (later designated GW170817) with merger time 12:41:04 UTC was observed through gravitational waves by the Advanced LIGO and Advanced Virgo detectors. The Fermi Gamma-ray Burst Monitor independently detected a gamma-ray burst (GRB 170817A) with a time delay of ~1.7 s with respect to the merger time. From the gravitational-wave signal, the source was initially localized to a sky region of 31 deg2 at a luminosity distance of 40+8-8 Mpc and with component masses consistent with neutron stars. The component masses were later measured to be in the range 0.86 to 2.26 Mo. An extensive observing campaign was launched across the electromagnetic spectrum leading to the discovery of a bright optical transient (SSS17a, now with the IAU identification of AT 2017gfo) in NGC 4993 (at ~40 Mpc) less than 11 hours after the merger by the One- Meter, Two Hemisphere (1M2H) team using the 1 m Swope Telescope. The optical transient was independently detected by multiple teams within an hour. Subsequent observations targeted the object and its environment. Early ultraviolet observations revealed a blue transient that faded within 48 hours. Optical and infrared observations showed a redward evolution over ~10 days. Following early non-detections, X-ray and radio emission were discovered at the transient’s position ~9 and ~16 days, respectively, after the merger. Both the X-ray and radio emission likely arise from a physical process that is distinct from the one that generates the UV/optical/near-infrared emission. No ultra-high-energy gamma-rays and no neutrino candidates consistent with the source were found in follow-up searches. These observations support the hypothesis that GW170817 was produced by the merger of two neutron stars in NGC4993 followed by a short gamma-ray burst (GRB 170817A) and a kilonova/macronova powered by the radioactive decay of r-process nuclei synthesized in the ejecta
- …