2,297 research outputs found

    Intraoperative device closure of atrial septal defects with inferior vena cava rim deficiency: A safe alternative to surgical repair

    Get PDF
    ObjectiveOur objective was to evaluate the safety and feasibility of intraoperative device closure of atrial septal defects with inferior vena cava rim deficiency.MethodsFrom January 2005 to December 2008, we enrolled 65 patients who had a secundum atrial septal defect with inferior vena cava rim deficiency closure in our institution. Patients were divided into 2 groups: 35 patients in group I underwent intraoperative device closure with a right lateral minithoracotomy and 30 in group II underwent open cardiac repair with a right lateral thoracotomy and cardiopulmonary bypass. Intraoperative device closure involved a minimal intercostal incision that was performed after full evaluation of the atrial septal defect by transthoracic echocardiography and the insertion of the device through the delivery sheath to occlude the atrial septal defect.ResultsThe procedure was successful in all patients. In group I, the diameter of the atrial septal defect ranged from 30 to 44 mm (mean, 35.3 ± 3.9 mm), and the size of the implanted occluder ranged from 34 to 48 mm (mean, 40 ± 2.1 mm). The total occlusion rate was 82.9% immediately after the operation, 97.1% at 3 months, and 100% at 12 and 24 months of follow-up. In group II, all patients had successful closure. A follow-up period of 12 to 24 months was obtained in both groups. During the follow-up, there was no recurrence, thrombosis, or device failure. In our comparative studies, group II had significantly longer operative time, intensive care unit stay, and hospital stay than group I (P < .001). The cost of group I was less than that of group II (20,450.9 ± 840.8 RMB vs 25,884.9 ± 701.8; P < .001).ConclusionsIntraoperative device closure of atrial septal defects with inferior vena cava rim deficiency is a safe and feasible technique. It has the advantages of cost savings, cosmetic results, and less trauma than surgical closure. Early and midterm results are encouraging

    Study of the expression levels of Hepatocyte nuclear factor 4 alpha and 3 beta in patients with different outcome of HBV infection

    Get PDF
    Hepatocyte nuclear factors 4 alpha (HNF4α) and 3 beta (HNF3β) are members of a group of liver-enriched transcription factors (LETFs) that play important roles in regulating the replication of hepatitis B virus (HBV) and liver inflammation. However, the relationship of the level of HNF4α and HNF3β with the severity of HBV-infected liver diseases is unclear. In this study, liver tissue samples from different types of HBV patients were collected, and HNF4α and HNF3β expression were detected by immunohistochemistry. The expression of HNF4α was significant higher in patients with severe hepatitis B(SHB) than those with chronic hepatitis B(CHB) and liver cirrhosis(LC) (both P < 0.05), but similar between patients with CHB and LC (P > 0.05). And the expression of HNF3β was similar among patients with CHB, LC and SHB (P > 0.05 for all pairwise comparison). This suggests that the expression level of HNF4α was different in patients with different outcome of HBV infection, high expression level of HNF4α may correlate with occurrence of SH

    Electrical conductance study on 1,3-butadiyne-linked dinuclear ruthenium(II) complexes within single molecule break junctions

    Get PDF
    NSFC [20931006, U0934003, 91122006]; NSF of Fujian Province [2011J01065]Single-molecule conductance of three sulphur-functionalized organometallic wires with two ruthenium(II) centres spaced by 1,3-butadiyne was firstly investigated using an electrochemically assisted-mechanically controllable break junction (EC-MCBJ) approach. It is demonstrated that single-molecular conductance of these diruthenium(II) incorporated systems is significantly higher than oligo(phenylene-ethynylene) (OPE) having comparable lengths and exhibits weaker length dependence. The conductance improvement in these diruthenium(II) molecules is ascribable to the better energy match of the Fermi level of gold electrodes with the HOMO that is mainly resident on the Ru-C C-C C-Ru backbone. Furthermore, modulation of molecular conductance is achieved by changing the length and pi-conjugated system of the chelating 2,2':6',2 ''-terpyridyl ligand

    Intraoperative device closure of atrial septal defects in the Older Population

    Get PDF
    <p>Abstract</p> <p>Objective</p> <p>This study sought to prove the safety and feasibility of intraoperative device closure of atrial septal defect (ASD) with transthoracic minimal invasion in the older patients.</p> <p>Methods</p> <p>From January 2006 to December 2009, 47 patients aged 50 years or more and suffered from atrial septal defect were enrolled in our institution. Patients were divided into two groups, 27 of which in group I with intraoperative device closure and the other 20 in group II with surgical closure. In group I, the method involved a minimal intercostal incision, which was performed after full evaluation of the atrial septal defect by transthoracic echocardiography, and the insertion of the device through the delivery sheath to occlude the atrial septal defect.</p> <p>Results</p> <p>In group I, implantation was ultimately successful in all patients. The complete closure rate at 24 hours and 1 year were 81.5% and 100% respectively. In 6 of 27 patients, minor complications occurred: transient arrhythmia (n = 5) and blood transfusion (n = 3). In group II, all patients were closured successfully; almost all of them needed blood transfusion and suffered from various minor complications though. During a follow-up period of 1 to 5 years, no residual shunt, noticeable mitral regurgitation, significant arrhythmias, thrombosis, or device failure were found. In our comparative studies, group II had significantly longer ICU stay and hospital stay than group I (p < 0.05). The cost of group I was less than that of group II(p < 0.05).</p> <p>Conclusions</p> <p>Minimally invasive transthoracic device closure of the atrial septal defect at advanced age with a domestically made device without cardiopulmonary bypass is safe and feasible under transthoracic echocardiographic guidance. It was cost-savings, yielding better cosmetic results and leaving fewer traumas than surgical closure. Early and mid-term results are encouraging. However, it is necessary to evaluate the long-term results.</p

    Rabdosia japonica

    Get PDF
    Rabdosia japonica var. glaucocalyx (Maxim.) Hara, belonging to the Labiatae family, is widely used as an anti-inflammatory and antitumor drug for the treatment of different inflammations and cancers. Aim of the Study. To investigate therapeutic effects and possible mechanism of the flavonoids fraction of Rabdosia japonica var. glaucocalyx (Maxim.) Hara (RJFs) in acute lung injury (ALI) mice induced by lipopolysaccharide (LPS). Materials and Methods. Mice were orally administrated with RJFs (6.4, 12.8, and 25.6 mg/kg) per day for 7 days, consecutively, before LPS challenge. Lung specimens and the bronchoalveolar lavage fluid (BALF) were isolated for histopathological examinations and biochemical analysis. The level of complement 3 (C3) in serum was quantified by a sandwich ELISA kit. Results. RJFs significantly attenuated LPS-induced ALI via reducing productions of the level of inflammatory mediators (TNF-α, IL-6, and IL-1β), and significantly reduced complement deposition with decreasing the level of C3 in serum, which was exhibited together with the lowered myeloperoxidase (MPO) activity and nitric oxide (NO) and protein concentration in BALF. Conclusions. RJFs significantly attenuate LPS-induced ALI via reducing productions of proinflammatory mediators, decreasing the level of complement, and reducing radicals

    Area Disease Estimation Based on Sentinel Hospital Records

    Get PDF
    BACKGROUND: Population health attributes (such as disease incidence and prevalence) are often estimated using sentinel hospital records, which are subject to multiple sources of uncertainty. When applied to these health attributes, commonly used biased estimation techniques can lead to false conclusions and ineffective disease intervention and control. Although some estimators can account for measurement error (in the form of white noise, usually after de-trending), most mainstream health statistics techniques cannot generate unbiased and minimum error variance estimates when the available data are biased. METHODS AND FINDINGS: A new technique, called the Biased Sample Hospital-based Area Disease Estimation (B-SHADE), is introduced that generates space-time population disease estimates using biased hospital records. The effectiveness of the technique is empirically evaluated in terms of hospital records of disease incidence (for hand-foot-mouth disease and fever syndrome cases) in Shanghai (China) during a two-year period. The B-SHADE technique uses a weighted summation of sentinel hospital records to derive unbiased and minimum error variance estimates of area incidence. The calculation of these weights is the outcome of a process that combines: the available space-time information; a rigorous assessment of both, the horizontal relationships between hospital records and the vertical links between each hospital's records and the overall disease situation in the region. In this way, the representativeness of the sentinel hospital records was improved, the possible biases of these records were corrected, and the generated area incidence estimates were best linear unbiased estimates (BLUE). Using the same hospital records, the performance of the B-SHADE technique was compared against two mainstream estimators. CONCLUSIONS: The B-SHADE technique involves a hospital network-based model that blends the optimal estimation features of the Block Kriging method and the sample bias correction efficiency of the ratio estimator method. In this way, B-SHADE can overcome the limitations of both methods: Block Kriging's inadequacy concerning the correction of sample bias and spatial clustering; and the ratio estimator's limitation as regards error minimization. The generality of the B-SHADE technique is further demonstrated by the fact that it reduces to Block Kriging in the case of unbiased samples; to ratio estimator if there is no correlation between hospitals; and to simple statistic if the hospital records are neither biased nor space-time correlated. In addition to the theoretical advantages of the B-SHADE technique over the two other methods above, two real world case studies (hand-foot-mouth disease and fever syndrome cases) demonstrated its empirical superiority, as well

    Tools to Support Policy Decisions Related to Treatment Strategies and Surveillance of Schistosomiasis Japonica towards Elimination

    Get PDF
    Immunodiagnostic assays are widely applied in the field to control schistosomiasis in P.R. China as the prevalence and infection intensity of schistosome infections decrease. Field evaluations are urgently needed before they can be adopted to support policy decisions of the national programme for the control and elimination of schistosomiasis in P.R. China. We carried out a large scale cross-sectional survey in field settings with different transmission situations to validate immunodiagnostic tools that can be used to formulate new schistosomiasis elimination strategy in P.R. China. Regarding stool examination as gold reference, the validity and screening efficacy of each immunodiagnostic kit were calculated and compared with each other. The association of the prevalence of schistosomiasis and antibody positive rates determined by immunoassays were analyzed using Pearson's correlation coefficient values. The study indicates that which test to use with the elimination strategy is dependent on the purpose of testing, the endemic status of community and the resources available. And more sensitive methods need to be explored and used to target infected individuals for treatment or to eliminate schistosomiasis

    Measurement of the cross-section and charge asymmetry of WW bosons produced in proton-proton collisions at s=8\sqrt{s}=8 TeV with the ATLAS detector

    Get PDF
    This paper presents measurements of the W+μ+νW^+ \rightarrow \mu^+\nu and WμνW^- \rightarrow \mu^-\nu cross-sections and the associated charge asymmetry as a function of the absolute pseudorapidity of the decay muon. The data were collected in proton--proton collisions at a centre-of-mass energy of 8 TeV with the ATLAS experiment at the LHC and correspond to a total integrated luminosity of 20.2~\mbox{fb^{-1}}. The precision of the cross-section measurements varies between 0.8% to 1.5% as a function of the pseudorapidity, excluding the 1.9% uncertainty on the integrated luminosity. The charge asymmetry is measured with an uncertainty between 0.002 and 0.003. The results are compared with predictions based on next-to-next-to-leading-order calculations with various parton distribution functions and have the sensitivity to discriminate between them.Comment: 38 pages in total, author list starting page 22, 5 figures, 4 tables, submitted to EPJC. All figures including auxiliary figures are available at https://atlas.web.cern.ch/Atlas/GROUPS/PHYSICS/PAPERS/STDM-2017-13

    Search for new phenomena in final states with an energetic jet and large missing transverse momentum in pp collisions at √ s = 8 TeV with the ATLAS detector

    Get PDF
    Results of a search for new phenomena in final states with an energetic jet and large missing transverse momentum are reported. The search uses 20.3 fb−1 of √ s = 8 TeV data collected in 2012 with the ATLAS detector at the LHC. Events are required to have at least one jet with pT > 120 GeV and no leptons. Nine signal regions are considered with increasing missing transverse momentum requirements between Emiss T > 150 GeV and Emiss T > 700 GeV. Good agreement is observed between the number of events in data and Standard Model expectations. The results are translated into exclusion limits on models with either large extra spatial dimensions, pair production of weakly interacting dark matter candidates, or production of very light gravitinos in a gauge-mediated supersymmetric model. In addition, limits on the production of an invisibly decaying Higgs-like boson leading to similar topologies in the final state are presente
    corecore