1,335 research outputs found

    Association of toll-interacting protein gene polymorphisms with atopic dermatitis

    Get PDF
    BACKGROUND: Atopic dermatitis (AD) is a common inflammatory skin disorder, affecting up to 15% of children in industrialized countries. Toll-interacting protein (TOLLIP) is an inhibitory adaptor protein within the toll-like receptor (TLR) pathway, a part of the innate immune system that recognizes structurally conserved molecular patterns of microbial pathogens, leading to an inflammatory immune response. METHODS: In order to detect a possible role of TOLLIP variation in the pathogenesis of AD, we screened the entire coding sequence of the TOLLIP gene by SSCP in 50 AD patients. We identified an amino acid exchange in exon 6 (Ala222Ser) and a synonymous variation in exon 4 (Pro139Pro). Subsequently, these two variations and four additional non-coding polymorphisms (-526 C/G, two polymorphisms in intron 1 and one in the 3'UTR) were genotyped in 317 AD patients and 224 healthy controls. RESULTS: The -526G allele showed borderline association with AD in our cohort (p = 0.012; significance level after correction for multiple testing 0.0102). Haplotype analysis did not yield additional information. Evaluation of mRNA expression by quantitative real-time polymerase chain reaction in six probands with the CC and six with the GG genotype at the -526 C/G locus did not reveal significant differences between genotypes. CONCLUSION: Variation in the TOLLIP gene may play a role in the pathogenesis of AD. Yet, replication studies in other cohorts and populations are warranted to confirm these association results

    The temporal reliability of serum estrogens, progesterone, gonadotropins, SHBG and urinary estrogen and progesterone metabolites in premenopausal women

    Get PDF
    BACKGROUND: There is little existing research to guide researchers in estimating the minimum number of measurement occasions required to obtain reliable estimates of serum estrogens, progesterone, gonadotropins, sex hormone-binding globulin (SHBG), and urinary estrogen and progesterone metabolites in premenopausal women. METHODS: Using data from a longitudinal study of 34 women with a mean age of 42.3 years (SD = 2.6), we calculated the minimum number of measurement occasions required to obtain reliable estimates of 12 analytes (8 in blood, 4 in urine). Five samples were obtained over 1 year: at baseline, and after 1, 3, 6, and 12 months. We also calculated the percent of true variance accounted for by a single measurement and intraclass correlation coefficients (ICC) between measurement occasions. RESULTS: Only 2 of the 12 analytes we examined, SHBG and estrone sulfate (E(1)S), could be adequately estimated by a single measurement using a minimum reliability standard of having the potential to account for 64% of true variance. Other analytes required from 2 to 12 occasions to account for 81% of the true variance, and 2 to 5 occasions to account for 64% of true variance. ICCs ranged from 0.33 for estradiol (E(2)) to 0.88 for SHBG. Percent of true variance accounted for by single measurements ranged from 29% for luteinizing hormone (LH) to 92% for SHBG. CONCLUSIONS: Experimental designs that take the natural variability of these analytes into account by obtaining measurements on a sufficient number of occasions will be rewarded with increased power and accuracy

    Perception of improvement after orthognathic surgery: the important variables affecting patient satisfaction

    Get PDF
    PURPOSE: We evaluated which factors affect patient satisfaction and if patient expectations were fulfilled after orthognathic surgery. METHODS: Questionnaires consisting of 14 questions were given 1 year after bimaxillary osteotomy for class-III correction to subjects. Six questions were answered using an 11-point rating scale based on a visual analog scale (VAS; 0 = poor; 10 = excellent). Also included were seven closed-form questions with yes/no answers, as well as one open question for 'further remarks'. Sagittal and vertical cephalometric parameters were determined on postoperative cephalograms. RESULTS: Seventy-seven patients (37 females, 40 males; mean age, 23.4 +/- 4.9 (SD) years) responded. The intention to undergo surgery only for aesthetic improvement was noted in 11.9% of patients; only improvement of chewing function in 15.5%; both in 71.4%; and none/don't know in 2.6%. Postoperative satisfaction was rated (in means) with 8.13 +/- 1.97 on VAS and correlated significantly with the opinions of friends and relatives. Facial aesthetics was rated 5.6 +/- 1.2 before surgery and 8.1 +/- 1.5 after surgery (p = 0.04). Preoperative chewing function was rated 5.65 +/- 1.8 and 8.03 +/- 1.51 after surgery (p = 0.014). TMJ disorders or hypoesthesia had no negative impacts. Cephalometric analyses revealed a significantly lower SNB (75.3 degrees +/- 2.7 degrees ; p = 0.033) in patients rating lower than grade 7 for overall satisfaction. For SNA and ArGoMe, no significant differences were observed. CONCLUSION: The most distinctive factors for patient satisfaction after orthognathic surgery were chewing function and facial aesthetics with respect to the lower face. Function, aesthetics, and even psychological aspects should be considered equally when planning surgery

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV

    Get PDF
    The azimuthal anisotropy of charged particles in PbPb collisions at nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS detector at the LHC over an extended transverse momentum (pt) range up to approximately 60 GeV. The data cover both the low-pt region associated with hydrodynamic flow phenomena and the high-pt region where the anisotropies may reflect the path-length dependence of parton energy loss in the created medium. The anisotropy parameter (v2) of the particles is extracted by correlating charged tracks with respect to the event-plane reconstructed by using the energy deposited in forward-angle calorimeters. For the six bins of collision centrality studied, spanning the range of 0-60% most-central events, the observed v2 values are found to first increase with pt, reaching a maximum around pt = 3 GeV, and then to gradually decrease to almost zero, with the decline persisting up to at least pt = 40 GeV over the full centrality range measured.Comment: Replaced with published version. Added journal reference and DO

    Search for new physics with same-sign isolated dilepton events with jets and missing transverse energy

    Get PDF
    A search for new physics is performed in events with two same-sign isolated leptons, hadronic jets, and missing transverse energy in the final state. The analysis is based on a data sample corresponding to an integrated luminosity of 4.98 inverse femtobarns produced in pp collisions at a center-of-mass energy of 7 TeV collected by the CMS experiment at the LHC. This constitutes a factor of 140 increase in integrated luminosity over previously published results. The observed yields agree with the standard model predictions and thus no evidence for new physics is found. The observations are used to set upper limits on possible new physics contributions and to constrain supersymmetric models. To facilitate the interpretation of the data in a broader range of new physics scenarios, information on the event selection, detector response, and efficiencies is provided.Comment: Published in Physical Review Letter

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Compressed representation of a partially defined integer function over multiple arguments

    Get PDF
    In OLAP (OnLine Analitical Processing) data are analysed in an n-dimensional cube. The cube may be represented as a partially defined function over n arguments. Considering that often the function is not defined everywhere, we ask: is there a known way of representing the function or the points in which it is defined, in a more compact manner than the trivial one

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres
    • …
    corecore