3,214 research outputs found

    Design and performance of personal cooling garments based on three-layer laminates

    Get PDF
    Personal cooling systems are mainly based on cold air or liquids circulating through a tubing system. They are weighty, bulky and depend on an external power source. In contrast, the laminate-based technology presented here offers new flexible and light weight cooling garments integrated into textiles. It is based on a three-layer composite assembled from two waterproof, but water vapor permeable membranes and a hydrophilic fabric in between. Water absorbed in the fabric will be evaporated by the body temperature resulting in cooling energy. The laminate's high adaptiveness makes it possible to produce cooling garments even for difficult anatomic topologies. The determined cooling energy of the laminate depends mainly on the environmental conditions (temperature, relative humidity, wind): heat flux at standard climatic conditions (20°C, 65% R.H., wind 5km/h) has measured 423.2±52.6W/m2, water vapor transmission resistance, R et, 10.83±0.38m2Pa/W and thermal resistance, R ct, 0.010±0.002m2K/W. Thermal conductivity, k, changed from 0.048±0.003 (dry) to 0.244±0.018W/mK (water added). The maximum fall in skin temperature, ∆T max, under the laminate was 5.7±1.2°C, taken from a 12 subject study with a thigh cooling garment during treadmill walking (23°C, 50% R.H., no wind) and a significant linear correlation (R=0.85, P=0.01) between body mass index and time to reach 67% of ∆T max could be determine

    Clinical utility of a pediatric hand exoskeleton: identifying users, practicability, and acceptance, and recommendations for design improvement

    Full text link
    BACKGROUND Children and adolescents with upper limb impairments can experience limited bimanual performance reducing daily-life independence. We have developed a fully wearable pediatric hand exoskeleton (PEXO) to train or compensate for impaired hand function. In this study, we investigated its appropriateness, practicability, and acceptability. METHODS Children and adolescents aged 6-18 years with functional limitations in at least one hand due to a neurological cause were selected for this cross-sectional evaluation. We characterized participants by various clinical tests and quantified bimanual performance with the Assisting Hand Assessment (AHA). We identified children whose AHA scaled score increased by ≄ 7 points when using the hand exoskeleton and determined clinical predictors to investigate appropriateness. The time needed to don each component and the number of technical issues were recorded to evaluate practicability. For acceptability, the experiences of the patients and the therapist with PEXO were evaluated. We further noted any adverse events. RESULTS Eleven children (median age 11.4 years) agreed to participate, but data was available for nine participants. The median AHA scaled score was higher with PEXO (68; IQR: 59.5-83) than without (55; IQR: 37.5-80.5; p = 0.035). The Box and Block test, the Selective Control of the Upper Extremity Scale, and finger extensor muscle strength could differentiate well between those participants who improved in AHA scaled scores by ≄ 7 points and those who did not (sensitivity and specificity varied between 0.75 and 1.00). The median times needed to don the back module, the glove, and the hand module were 62, 150, and 160 s, respectively, but all participants needed assistance. The most critical failures were the robustness of the transmission system, the electronics, and the attachment system. Acceptance was generally high, particularly in participants who improved bimanual performance with PEXO. Five participants experienced some pressure points. No adverse events occurred. CONCLUSIONS PEXO is a safe exoskeleton that can improve bimanual hand performance in young patients with minimal hand function. PEXO receives high acceptance. We formulated recommendations to improve technical issues and the donning before such exoskeletons can be used under daily-life conditions for therapy or as an assistive device. Trial registration Not appropriate

    The Variable Influence of Orthotic Management on Hip and Pelvic Rotation in Children with Unilateral Neurogenic Equinus Deformity

    Full text link
    BACKGROUND Equinus deformity with or without concomitant drop foot is a common finding in children with unilateral spastic cerebral palsy and spastic hemiplegia of other causes. Hypothetically, these deformities may lead to pelvic retraction and hip internal rotation during gait. Orthoses are used to reduce pes equinus during gait and to restore hindfoot first contact. OBJECTIVE We aimed to investigate whether the use of orthotic equinus correction reduces rotational hip and pelvic asymmetries. METHODS In a retrospective study, 34 children with unilateral spastic cerebral palsy or spastic hemiplegia of other causes underwent standardized instrumented 3D gait analysis with and without orthotic equinus management. We analyzed the differences in the torsional profile during barefoot walking and while wearing orthoses, as well as investigated the influence of ankle dorsiflexion and femoral anteversion on pelvic and hip kinematics and hip kinetics. RESULTS Wearing orthoses corrected pes equinus and pelvic internal rotation at the end of the stance phase and in the swing phase compared to barefoot walking. Hip rotation and the rotational moment did not significantly change with orthoses. Orthotic management or femoral anteversion did not correlate to pelvic and hip asymmetry. CONCLUSION The findings indicate that the correction of the equinus by using orthoses had a variable effect on the asymmetry of the hip and pelvis and internal rotation; both appear to have a multifactorial cause that is not primarily driven by the equinus component

    Identifying Drivers of Seasonality in Lena River Biogeochemistry and Dissolved Organic Matter Fluxes

    Get PDF
    Warming air temperatures, shifting hydrological regimes and accelerating permafrost thaw in the catchments of the Arctic rivers is affecting their biogeochemistry. Arctic river monitoring is necessary to observe changes in the mobilization of dissolved organic matter (DOM) from permafrost. The Lena River is the second largest Arctic river and 71% of its catchment is continuous permafrost. Biogeochemical parameters, including temperature, electrical conductivity (EC), stable water isotopes, dissolved organic carbon (DOC) and absorption by colored dissolved organic matter (aCDOM) have been measured as part of a new high-frequency sampling program in the central Lena River Delta. The results show strong seasonal variations of all biogeochemical parameters that generally follow seasonal patterns of the hydrograph. Optical indices of DOM indicate a trend of decreasing aromaticity and molecular weight from spring to winter. High-frequency sampling improved our estimated annual fluvial flux of annual dissolved organic carbon flux (6.79 Tg C). EC and stable isotope data were used to distinguish three different source water types which explain most of the seasonal variation in the biogeochemistry of the Lena River. These water types match signatures of (1) melt water, (2) rain water, and (3) subsurface water. Melt water and rain water accounted for 84% of the discharge flux and 86% of the DOC flux. The optical properties of melt water DOM were characteristic of fresh organic matter. In contrast, the optical properties of DOM in subsurface water revealed lower aromaticity and lower molecular weights, which indicate a shift toward an older organic matter source mobilized from deeper soil horizons or permafrost deposits. The first year of this new sampling program sets a new baseline for flux calculations of dissolved matter and has enabled the identification and characterization of water types that drive the seasonality of the Lena River water properties

    Ambipolar charge injection and transport in a single pentacene monolayer island

    Full text link
    Electrons and holes are locally injected in a single pentacene monolayer island. The two-dimensional distribution and concentration of the injected carriers are measured by electrical force microscopy. In crystalline monolayer islands, both carriers are delocalized over the whole island. On disordered monolayer, carriers stay localized at their injection point. These results provide insight into the electronic properties, at the nanometer scale, of organic monolayers governing performances of organic transistors and molecular devices.Comment: To be published in Nano Letter

    Assessment of compression forces in a digitally modified short leg cast for pressure injury risk monitoring in healthy children

    Get PDF
    IntroductionCasting is an essential treatment for neuro-orthopedic conditions in children with cognitive, sensory, and communicational disabilities. However, a main side-effect is the development of pressure injuries resulting in additional (wound) therapies and prolongation of the hospital stay. The primary aim of our study was to investigate the potential of objective pressure measurements in casts to assess the risk for pressure injury development.MethodsFive pediatric healthy participants were included in this study. We measured the global and the local compression force at body sites prone to pressure injury development for different body positions and the transfer in-between in a cast equipped with pressure sensors. These conditions resulted in partial or full body weight loading.Results and discussionThe global maximum compression force was affected significantly by body postures with partial and full loading of the cast and during transfer. The local compression force significantly correlated with the global compression force at the heel and instep area. In conclusion, the integration of sensing technologies into casts bears a high potential for early recognition of critical conditions inside the cast and inducing preventive measures in the at-risk population

    The Job Search Intensity Supply Curve: How Labor Market Conditions Affect Job Search Effort

    Get PDF
    During the Great Recession of 2007, unemployment reached nearly 10 percent and the ratio of unemployment to open positions (as measured by the Help Wanted OnLine Index) more than tripled. The weak labor market prompted an unprecedented extension in the length of time in which a claimant can collect unemployment insurance (UI) to 99 weeks, at an expense to date of $226.4 billion. While many claim that extending UI during a recession will reduce search intensity, the effect of weak labor market conditions on search remains a mystery. As a result, policymakers are in the dark as to whether UI extensions reduce already low search effort during recessions or perhaps decrease excessive search, which causes congestion in the labor market. At the same time, modelers of the labor market have little empirical justification for their assumptions on how search intensity changes over the business cycle. This paper develops a search model where the impact of macro labor market conditions on a worker’s search effort depends on whether these two factors are substitutes or complements in the job search process. Parameter estimates of the structural model using a sample of unemployment spells from the National Longitudinal Survey of Youth 1997 indicate that macro labor market conditions and individual search effort are complements and move together over the business cycle. The estimation also reveals that more risk-averse and less wealthy individuals exhibit less search effort

    Influence of virtual reality soccer game on walking performance in robotic assisted gait training for children

    Get PDF
    BACKGROUND: Virtual reality (VR) offers powerful therapy options within a functional, purposeful and motivating context. Several studies have shown that patients' motivation plays a crucial role in determining therapy outcome. However, few studies have demonstrated the potential of VR in pediatric rehabilitation. Therefore, we developed a VR-based soccer scenario, which provided interactive elements to engage patients during robotic assisted treadmill training (RAGT). The aim of this study was to compare the immediate effect of different supportive conditions (VR versus non-VR conditions) on motor output in patients and healthy control children during training with the driven gait orthosis Lokomat*. METHODS: A total of 18 children (ten patients with different neurological gait disorders, eight healthy controls) took part in this study. They were instructed to walk on the Lokomat in four different, randomly-presented conditions: (1) walk normally without supporting assistance, (2) with therapists' instructions to promote active participation, (3) with VR as a motivating tool to walk actively and (4) with the VR tool combined with therapists' instructions. The Lokomat gait orthosis is equipped with sensors at hip and knee joint to measure man-machine interaction forces. Additionally, subjects' acceptance of the RAGT with VR was assessed using a questionnaire. RESULTS: The mixed ANOVA revealed significant main effects for the factor CONDITIONS (p < 0.001) and a significant interaction CONDITIONS x GROUP (p = 0.01). Tests of between-subjects effects showed no significant main effect for the GROUP (p = 0.592). Active participation in patients and control children increased significantly when supported and motivated either by therapists' instructions or by a VR scenario compared with the baseline measurement "normal walking" (p < 0.001). CONCLUSIONS: The VR scenario used here induces an immediate effect on motor output to a similar degree as the effect resulting from verbal instructions by the therapists. Further research needs to focus on the implementation of interactive design elements, which keep motivation high across and beyond RAGT sessions, especially in pediatric rehabilitation

    Measurement of the cross-section and charge asymmetry of WW bosons produced in proton-proton collisions at s=8\sqrt{s}=8 TeV with the ATLAS detector

    Get PDF
    This paper presents measurements of the W+→Ό+ÎœW^+ \rightarrow \mu^+\nu and W−→Ό−ΜW^- \rightarrow \mu^-\nu cross-sections and the associated charge asymmetry as a function of the absolute pseudorapidity of the decay muon. The data were collected in proton--proton collisions at a centre-of-mass energy of 8 TeV with the ATLAS experiment at the LHC and correspond to a total integrated luminosity of 20.2~\mbox{fb^{-1}}. The precision of the cross-section measurements varies between 0.8% to 1.5% as a function of the pseudorapidity, excluding the 1.9% uncertainty on the integrated luminosity. The charge asymmetry is measured with an uncertainty between 0.002 and 0.003. The results are compared with predictions based on next-to-next-to-leading-order calculations with various parton distribution functions and have the sensitivity to discriminate between them.Comment: 38 pages in total, author list starting page 22, 5 figures, 4 tables, submitted to EPJC. All figures including auxiliary figures are available at https://atlas.web.cern.ch/Atlas/GROUPS/PHYSICS/PAPERS/STDM-2017-13

    Single hadron response measurement and calorimeter jet energy scale uncertainty with the ATLAS detector at the LHC

    Get PDF
    The uncertainty on the calorimeter energy response to jets of particles is derived for the ATLAS experiment at the Large Hadron Collider (LHC). First, the calorimeter response to single isolated charged hadrons is measured and compared to the Monte Carlo simulation using proton-proton collisions at centre-of-mass energies of sqrt(s) = 900 GeV and 7 TeV collected during 2009 and 2010. Then, using the decay of K_s and Lambda particles, the calorimeter response to specific types of particles (positively and negatively charged pions, protons, and anti-protons) is measured and compared to the Monte Carlo predictions. Finally, the jet energy scale uncertainty is determined by propagating the response uncertainty for single charged and neutral particles to jets. The response uncertainty is 2-5% for central isolated hadrons and 1-3% for the final calorimeter jet energy scale.Comment: 24 pages plus author list (36 pages total), 23 figures, 1 table, submitted to European Physical Journal
    • 

    corecore