51 research outputs found

    Intrapulmonary shunting and pulmonary gas exchange during normoxic and hypoxic exercise in healthy humans

    Get PDF
    Exercise-induced intrapulmonary arteriovenous shunting, as detected by saline contrast echocardiography, has been demonstrated in healthy humans. We have previously suggested that increases in both pulmonary pressures and blood flow associated with exercise are responsible for opening these intrapulmonary arteriovenous pathways. In the present study, we hypothesized that, although cardiac output and pulmonary pressures would be higher in hypoxia, the potent pulmonary vasoconstrictor effect of hypoxia would actually attenuate exercise-induced intrapulmonary shunting. Using saline contrast echocardiography, we examined nine healthy men during incremental (65W + 30 W/2 min) cycle exercise to exhaustion in normoxia and hypoxia (fraction of inspired O-2 = 0.12). Contrast injections were made into a peripheral vein at rest and during exercise and recovery (3-5 min postexercise) with pulmonary gas exchange measured simultaneously. At rest, no subject demonstrated intrapulmonary shunting in normoxia [ arterial P-O2 (Pa-O2) = 98 +/- 10 Torr], whereas in hypoxia (Pa-O2 = 47 +/- 5 Torr), intrapulmonary shunting developed in 3/9 subjects. During exercise, similar to 90% (8/9) of the subjects shunted during normoxia, whereas all subjects shunted during hypoxia. Four of the nine subjects shunted at a lower workload in hypoxia. Furthermore, all subjects continued to shunt at 3 min, and five subjects shunted at 5 min postexercise in hypoxia. Hypoxia has acute effects by inducing intrapulmonary arteriovenous shunt pathways at rest and during exercise and has longterm effects by maintaining patency of these vessels during recovery. Whether oxygen tension specifically regulates these novel pathways or opens them indirectly via effects on the conventional pulmonary vasculature remains unclear

    Multi-messenger observations of a binary neutron star merger

    Get PDF
    On 2017 August 17 a binary neutron star coalescence candidate (later designated GW170817) with merger time 12:41:04 UTC was observed through gravitational waves by the Advanced LIGO and Advanced Virgo detectors. The Fermi Gamma-ray Burst Monitor independently detected a gamma-ray burst (GRB 170817A) with a time delay of ~1.7 s with respect to the merger time. From the gravitational-wave signal, the source was initially localized to a sky region of 31 deg2 at a luminosity distance of 40+8-8 Mpc and with component masses consistent with neutron stars. The component masses were later measured to be in the range 0.86 to 2.26 Mo. An extensive observing campaign was launched across the electromagnetic spectrum leading to the discovery of a bright optical transient (SSS17a, now with the IAU identification of AT 2017gfo) in NGC 4993 (at ~40 Mpc) less than 11 hours after the merger by the One- Meter, Two Hemisphere (1M2H) team using the 1 m Swope Telescope. The optical transient was independently detected by multiple teams within an hour. Subsequent observations targeted the object and its environment. Early ultraviolet observations revealed a blue transient that faded within 48 hours. Optical and infrared observations showed a redward evolution over ~10 days. Following early non-detections, X-ray and radio emission were discovered at the transient’s position ~9 and ~16 days, respectively, after the merger. Both the X-ray and radio emission likely arise from a physical process that is distinct from the one that generates the UV/optical/near-infrared emission. No ultra-high-energy gamma-rays and no neutrino candidates consistent with the source were found in follow-up searches. These observations support the hypothesis that GW170817 was produced by the merger of two neutron stars in NGC4993 followed by a short gamma-ray burst (GRB 170817A) and a kilonova/macronova powered by the radioactive decay of r-process nuclei synthesized in the ejecta

    Care Everywhere, a Point-to-Point HIE Tool

    No full text

    Feasibility of implementing pulse oximetry screening for congenital heart disease in a community hospital

    No full text
    OBJECTIVE: Pulse oximetry has been recognized as a promising screening tool for critical congenital heart disease (CCHD). The aim of this research was to study the feasibility of implementation in a community hospital setting. STUDY DESIGN: Meetings were conducted to determine an implementation plan. Pulse oximetry was performed on the right hand and foot after 24 h of age. Newborns with a saturation ⩽95% or a ⩾3% difference were considered to have a positive screen. Screening barriers, screening time and ability to effectively screen all eligible newborns were noted. RESULT: From January 2009 through May 2010, of 6841 eligible newborns, 6745 newborns (98.6%) were screened. Of the nine infants with positive pulse oximetry screens, one had CCHD, four had CHD and four others were determined to have false positive screens. Average screening time was 3.5 min (0 to 35 min). CONCLUSION: Pulse oximetry can be implemented successfully in community hospitals without an excessive number of false positives or additional nursing staff
    corecore