31 research outputs found

    Dual physiological rate measurement instrument

    Get PDF
    The object of the invention is to provide an instrument for converting a physiological pulse rate into a corresponding linear output voltage. The instrument which accurately measures the rate of an unknown rectangular pulse wave over an extended range of values comprises a phase-locked loop including a phase comparator, a filtering network, and a voltage-controlled oscillator, arranged in cascade. The phase comparator has a first input responsive to the pulse wave and a second input responsive to the output signal of the voltage-controlled oscillator. The comparator provides a signal dependent on the difference in phase and frequency between the signals appearing on the first and second inputs. A high-input impedance amplifier accepts an output from the filtering network and provides an amplified output DC signal to a utilization device for providing a measurement of the rate of the pulse wave

    Earpiece with sensors to measure/monitor multiple physiological variables

    Get PDF
    An apparatus and method for positioning sensors relative to one another and anatomic features in a non-invasive device for measuring and monitoring multiple physiological variables from a single site uses an earpiece incorporating a shielded pulse oximetry sensor (POS) having a miniaturized set of LEDs and photosensors configured for pulse oximetry measurements in the reflectance mode and located in the earpiece so as to position the POS against a rear wall of an ear canal. The earpiece also includes a thermopile of no larger than 7 mm. in diameter located on the earpiece to so as to position the thermopile past a second turn of an external auditory meatus so as to view the tympanic membrane. The thermopile includes a reference temperature sensor attached to its base for ambient temperature compensation

    Advanced sensors technology survey

    Get PDF
    This project assesses the state-of-the-art in advanced or 'smart' sensors technology for NASA Life Sciences research applications with an emphasis on those sensors with potential applications on the space station freedom (SSF). The objectives are: (1) to conduct literature reviews on relevant advanced sensor technology; (2) to interview various scientists and engineers in industry, academia, and government who are knowledgeable on this topic; (3) to provide viewpoints and opinions regarding the potential applications of this technology on the SSF; and (4) to provide summary charts of relevant technologies and centers where these technologies are being developed

    Optimized Photometric Redshifts for the Cosmic Assembly Near-Infrared Deep Extragalactic Legacy Survey (CANDELS)

    Get PDF
    We present the first comprehensive release of photometric redshifts (photo-z's) from the Cosmic Assembly Near-Infrared Deep Extragalactic Legacy Survey (CANDELS) team. We use statistics based upon the Quantile-Quantile (Q--Q) plot to identify biases and signatures of underestimated or overestimated errors in photo-z probability density functions (PDFs) produced by six groups in the collaboration; correcting for these effects makes the resulting PDFs better match the statistical definition of a PDF. After correcting each group's PDF, we explore three methods of combining the different groups' PDFs for a given object into a consensus curve. Two of these methods are based on identifying the minimum f-divergence curve, i.e., the PDF that is closest in aggregate to the other PDFs in a set (analogous to the median of an array of numbers). We demonstrate that these techniques yield improved results using sets of spectroscopic redshifts independent of those used to optimize PDF modifications. The best photo-z PDFs and point estimates are achieved with the minimum f-divergence using the best 4 PDFs for each object (mFDa4) and the Hierarchical Bayesian (HB4) methods, respectively. The HB4 photo-z point estimates produced σNMAD=0.0227/0.0189\sigma_{\rm NMAD} = 0.0227/0.0189 and Δz/(1+z)>0.15|\Delta z/(1+z)| > 0.15 outlier fraction = 0.067/0.019 for spectroscopic and 3D-HST redshifts, respectively. Finally, we describe the structure and provide guidance for the use of the CANDELS photo-z catalogs, which are available at https://archive.stsci.edu/hlsp/candels.Comment: 35 pages, 19 figures, submitted to ApJ, data available at https://archive.stsci.edu/hlsp/candel

    The course of the acute vertebral body fragility fracture: its effect on pain, disability and quality of life during 12 months

    Get PDF
    The vertebral body fracture is the most frequent bone fragility fracture. In spite of this there is considerable uncertainty about the frequency, extent and severity of the acute pain and even more about the duration of pain, the magnitude of disability and how much daily life is disturbed in the post-fracture period. The aim of the present study was to follow the course of pain, disability, ADL and QoL in patients during the year after an acute low energy vertebral body fracture. The study design was a longitudinal cohort study with prospective data collection. All the patients over 40 years admitted to the emergency unit because of back pain with a radiologically acute vertebral body fracture were eligible. A total of 107 patients were followed for a year. The pain, disability (von Korff pain and disability scores), ADL (Hannover ADL score), and QoL (EQ-5D) were measured after 3 weeks, 3, 6 and 12 months. Two-thirds of the patients were women, and were similar in average age, as the men around 75 years. A total of 65.4% of the fractures were due to a level fall or a minor trauma, whereas 34.6% had no recollection of trauma or a specific event as the cause of the fracture. A total of 76.6% of the fractured patients were immediately mobilized and allowed to return home while the remaining were hospitalized. The average pain intensity score after 3 weeks was 70.9 (SD 19.3), the disability score 68.9 (SD 23.6), the ADL score 37.7 (SD 22.1) and EQ-5D score of 0.37 (SD 0.37). The largest improvements, 10–15%, occurred between the initial visit and the 3 months follow-up and were quite similar for all the measures. From 3 months, all the outcome measures leveled out or tended to deteriorate resulting in a mean pain intensity score of 60.5, disability score of 53.9, ADL score of 47.6, and EQ-5D score 0.52 after 12 months. After a whole year the fractured patients’ condition was similar to the preoperative condition of patients with a herniated lumbar disc, central lumbar spinal stenosis or in patients 100% work disabled due to back or neck problems. Instead of the generally believed good prognosis for the greater majority of those fractured, the acute vertebral body fracture was the beginning of a long-lasting severe deterioration of their health

    The prognosis for pain, disability, activities of daily living and quality of life after an acute osteoporotic vertebral body fracture: its relation to fracture level, type of fracture and grade of fracture deformation

    Get PDF
    The level of the acute osteoporotic vertebral fracture, fracture type and grade of fracture deformation were determined in 107 consecutive patients and related to pain, disability, activities of daily living (ADL) and quality of life (QoL) after 3 weeks, 3, 6 and 12 months. Two-thirds of the fractured patients were women and with a similar average age, around 75 years, as the men. Fifty-eight of the acute fractures were located in the thoracic spine and 49 in the lumbar spine and predominantly at the Th12 and L1 levels. Sixty-nine percent of the fractures were wedge, 19% concave and 12% crush fractures. There were 22 mildly, 50 moderately and 35 severely deformed vertebrae. The grade of fracture deformation was not related to gender, age or fracture location. Severely deformed vertebrae predominantly (92%) occurred among the crush fracture type. One year after the fracture, irrespective of fracture level, fracture type or grade of fracture deformation, 4/5 still had pronounced pain and deteriorated QoL. Initial severe fracture deformation by far was the worst prognostic factor for severe lasting pain and disability, and deterioration of ADL and QoL. Factors like fracture level, lumbar fractures tended to improve steadily while thoracic deteriorated, type of fracture, the wedge and concave resulting in less pain and better QoL than the crush fracture type and gender influenced to a lesser extent the outcomes during the year after the acute fracture

    CANDELS: The Cosmic Assembly Near-infrared Deep Extragalactic Legacy Survey

    Get PDF
    The Cosmic Assembly Near-infrared Deep Extragalactic Legacy Survey (CANDELS) is designed to document the first third of galactic evolution, over the approximate redshift (z) range 8--1.5. It will image >250,000 distant galaxies using three separate cameras on the Hubble Space Telescope, from the mid-ultraviolet to the near-infrared, and will find and measure Type Ia supernovae at z>1.5 to test their accuracy as standardizable candles for cosmology. Five premier multi-wavelength sky regions are selected, each with extensive ancillary data. The use of five widely separated fields mitigates cosmic variance and yields statistically robust and complete samples of galaxies down to a stellar mass of 10^9 M_\odot to z \approx 2, reaching the knee of the ultraviolet luminosity function (UVLF) of galaxies to z \approx 8. The survey covers approximately 800 arcmin^2 and is divided into two parts. The CANDELS/Deep survey (5\sigma\ point-source limit H=27.7 mag) covers \sim 125 arcmin^2 within GOODS-N and GOODS-S. The CANDELS/Wide survey includes GOODS and three additional fields (EGS, COSMOS, and UDS) and covers the full area to a 5\sigma\ point-source limit of H \gtrsim 27.0 mag. Together with the Hubble Ultra Deep Fields, the strategy creates a three-tiered "wedding cake" approach that has proven efficient for extragalactic surveys. Data from the survey are nonproprietary and are useful for a wide variety of science investigations. In this paper, we describe the basic motivations for the survey, the CANDELS team science goals and the resulting observational requirements, the field selection and geometry, and the observing design. The Hubble data processing and products are described in a companion paper.Comment: Submitted to Astrophysical Journal Supplement Series; Revised version, subsequent to referee repor

    New loci for body fat percentage reveal link between adiposity and cardiometabolic disease risk

    Get PDF
    To increase our understanding of the genetic basis of adiposity and its links to cardiometabolic disease risk, we conducted a genome-wide association meta-analysis of body fat percentage (BF%) in up to 100,716 individuals. Twelve loci reached genome-wide significance (P<5 × 10−8), of which eight were previously associated with increased overall adiposity (BMI, BF%) and four (in or near COBLL1/GRB14, IGF2BP1, PLA2G6, CRTC1) were novel associations with BF%. Seven loci showed a larger effect on BF% than on BMI, suggestive of a primary association with adiposity, while five loci showed larger effects on BMI than on BF%, suggesting association with both fat and lean mass. In particular, the loci more strongly associated with BF% showed distinct cross-phenotype association signatures with a range of cardiometabolic traits revealing new insights in the link between adiposity and disease risk

    CANDELS multi-wavelength catalogs: source identification and photometry in the CANDELS Extended Groth Strip

    Get PDF
    We present a 0.4-8?m multi-wavelength photometric catalog in the Extended Groth Strip (EGS) field. This catalog is built on the Hubble Space Telescope (HST) WFC3 and ACS data from the Cosmic Assembly Near-infrared Deep Extragalactic Legacy Survey (CANDELS), and it incorporates the existing HST data from the All-wavelength Extended Groth strip International Survey (AEGIS) and the 3D-HST program. The catalog is based on detections in the F160W band reaching a depth of F160W=26.62 AB (90% completeness, point-sources). It includes the photometry for 41457 objects over an area of ~ 206 arcmin2 in the following bands: HST ACS F606W and F814W; HST WFC3 F125W, F140W and F160W; CFHT/Megacam u?, g?, r?, i? and z?; CFHT/WIRCAM J, H and KS; Mayall/NEWFIRM J1, J2, J3, H1, H2, K; Spitzer IRAC 3.6?m, 4.5?m, 5.8?m and 8.0?m. We are also releasing value-added catalogs that provide robust photometric redshifts and stellar mass measurements. The catalogs are publicly available through the CANDELS repository

    New loci for body fat percentage reveal link between adiposity and cardiometabolic disease risk

    Get PDF
    To increase our understanding of the genetic basis of adiposity and its links to cardiometabolic disease risk, we conducted a genome-wide association meta-analysis of body fat percentage (BF%) in up to 100,716 individuals. Twelve loci reached genome-wide significance (P <5 x 10(-8)), of which eight were previously associated with increased overall adiposity (BMI, BF%) and four (in or near COBLL1/GRB14, IGF2BP1, PLA2G6, CRTC1) were novel associations with BF%. Seven loci showed a larger effect on BF% than on BMI, suggestive of a primary association with adiposity, while five loci showed larger effects on BMI than on BF%, suggesting association with both fat and lean mass. In particular, the loci more strongly associated with BF% showed distinct cross-phenotype association signatures with a range of cardiometabolic traits revealing new insights in the link between adiposity and disease risk.Peer reviewe
    corecore