441 research outputs found

    Validation of Energy Dispersive X-Ray Spectrometry as a Method to Standardize Backscattered Electron Images of Bone

    Get PDF
    The use of backscattered electron (BSE) imaging as a tool for the qualitative measurement of mineral content in bone has been well documented. The challenge still remains to develop BSE imaging as a tool for quantitative mineral content analysis in bone. The limiting factor has been the ability to standardize the BSE signal within and between laboratories. Energy dispersive x-ray spectrometry (EDX) has been proposed as a method to standardize the BSE operating environment. The goal of this study is to investigate the relationship between EDX-determined wt.% Ca measurements and BSE graylevels. A comparison with traditional ash content measurements will indicate the validity of the procedure. A comparative study was performed on a series of bones representing a broad range of mineralization. Results confirmed a high correlation between BSE graylevels and wt.% Ca measured with EDX. However, the BSE method consistently underestimated the mineral content of bone determined by traditional ash measurements. The results suggest that quantitative BSE imaging can be standardized by EDX measurements, but an empirically determined correction may be necessary if comparisons with known and accepted mineral content measurement techniques are to be performed. Further investigation into the nature of this empirical correction is warranted before the procedure can be universally applied to bone mineral content analysis

    Consistency in Calibrated Backscattered Electron Images of Calcified Tissues and Minerals Analyzed in Multiple Imaging Sessions

    Get PDF
    Pure metal standards have been used to calibrate the operating environment in quantitative backscattered electron (BSE) imaging of mineralized tissue, allowing comparisons to be made between various mineralization states of bone at the microscopic level. It has not previously been documented that calibration procedures produce consistent, reliable results over multiple imaging sessions. In this study, BSE images were obtained from bones, pure metals, and a naturally occurring mineral in multiple imaging sessions over a six day period. The graylevel histogram profile (GHP) from each specimen was analyzed for changes in the shape and relative placement on the graylevel spectrum. Computer controlled calibration and a retrospective calibration method using pure aluminum and pure magnesium-aluminum-zinc demonstrated consistency between imaging sessions. Calibrated weighted mean gray levels (WMGLs) for biological materials had an average standard deviation of 5.9 graylevels (2.4% variation) during the course of the study. WMGLs for inorganic materials had an average standard deviation of 0.9 graylevels (0.4% variation). A trend towards increased image brightness, due to specimen and/or embedding media degradation, was observed in the biological tissues. No increase in brightness was observed for the inorganic specimens. Kurtosis and skewness tests revealed a slight deviation from normality in all specimens, which remained consistent between multiple imaging sessions. These results demonstrate that BSE image analysis of bones and mineral can be calibrated with negligible precision error allowing comparisons between data within and between multiple imaging sessions

    Prolonged Dyspnea after Interscalene Block: Attributed to Undiagnosed Addison's Disease and Myasthenia Gravis

    Get PDF
    This report describes a patient who had a series of daily interscalene nerve blocks to treat pain following a shoulder manipulation for postsurgical stiffness. She experienced acute respiratory compromise that persisted for many weeks. All typical and unusual causes of these symptoms were ruled out. Her treating pulmonologist theorized that the ipsilateral carotid body had been injured. However, it was subsequently determined that the constellation of symptoms and their prolonged duration were best explained by a poor stress response from Addison's disease coupled with exacerbation of early onset myasthenia gravis. This patient's case is not a typical reaction to interscalene nerve blocks, and thus preoperative testing would not be recommended for myasthenia gravis or Addison's disease without underlying suspicion. We describe this report to inform physicians to consider a workup for these diagnoses if a typical workup rules out all usual causes of complications from an interscalene block

    Reproducible Method for Calibrating the Backscattered Electron Signal for Quantitative Assessment of Mineral Content in Bone

    Get PDF
    Backscattered electron (BSE) imaging shows promise for orthopaedic and bone research. BSE images of bone may be captured on-line directly from the scanning electron microscope (SEM), and then analyzed to produce a backscattered electron profile (BSEP), a modified image graylevel histogram which is representative of the mineral content in bone. The goals of this work were 1) develop a reproducible graylevel calibration technique for bone specimens, and 2) determine a conservative time interval during which SEM operating conditions would remain stable. Calibration standards containing pure aluminum and pure magnesium wires were placed in the SEM with human cancellous bone. Baseline imaging conditions were first established by adjusting the SEM until the bone image displayed good resolution and graylevel separation between regions of different mineral content. Microscope brightness and contrast controls were randomly changed to initiate the new operating conditions of another imaging session, and graylevel values from the calibration metals were used to readjust the microscope back to baseline operating conditions. Weighted mean graylevel values of the BSEPs from calibration trials were compared to those of the baseline. Data showed that bone images could be reproduced within 1.2 percent. It was also concluded that our equipment required calibration checks at 20 minute intervals

    On the Mechanistic Origins of Toughness in Bone

    Get PDF
    One of the most intriguing protein materials found in nature is bone, a material composed of assemblies of tropocollagen molecules and tiny hydroxyapatite mineral crystals that form an extremely tough, yet lightweight, adaptive and multifunctional material. Bone has evolved to provide structural support to organisms, and therefore its mechanical properties are of great physiological relevance. In this article, we review the structure and properties of bone, focusing on mechanical deformation and fracture behavior from the perspective of the multidimensional hierarchical nature of its structure. In fact, bone derives its resistance to fracture with a multitude of deformation and toughening mechanisms at many size scales ranging from the nanoscale structure of its protein molecules to the macroscopic physiological scale.United States. Army Research Office (contract number W911NF-06-1-0291)National Science Foundation (U.S.) (CAREER award (contract number 0642545))Lawrence Berkeley National Laboratory (Laboratory Directed Research and Development Program)United States. Dept. of Energy (Office of Science, Office of Basic Energy Sciences, Division of Materials Sciences and Engineering, contract number DE-AC02-05CH11231

    Structure model index does not measure rods and plates in trabecular bone

    Get PDF
    Structure model index (SMI) is widely used to measure rods and plates in trabecular bone. It exploits the change in surface curvature that occurs as a structure varies from spherical (SMI = 4), to cylindrical (SMI = 3) to planar (SMI = 0). The most important assumption underlying SMI is that the entire bone surface is convex and that the curvature differential is positive at all points on the surface. The intricate connections within the trabecular continuum suggest that a high proportion of the surface could be concave, violating the assumption of convexity and producing regions of negative differential. We implemented SMI in the BoneJ plugin and included the ability to measure the amounts of surface that increased or decreased in area after surface mesh dilation, and the ability to visualize concave and convex regions. We measured SMI and its positive (SMI+) and negative (SMI-) components, bone volume fraction (BV/TV), the fraction of the surface that is concave (CF), and mean ellipsoid factor (EF) in trabecular bone using 38 X-ray microtomography (XMT) images from a rat ovariectomy model of sex steroid rescue of bone loss, and 169 XMT images from a broad selection of 87 species' femora (mammals, birds, and a crocodile). We simulated bone resorption by eroding an image of elephant trabeculae and recording SMI and BV/TV at each erosion step. Up to 70%, and rarely less than 20%, of the trabecular surface is concave (CF 0.155 – 0.700). SMI is unavoidably influenced by aberrations from SMI-, which is strongly correlated with BV/TV and CF. The plate-to-rod transition in bone loss is an erroneous observation resulting from SMI's close and artefactual relationship with BV/TV. SMI cannot discern between the distinctive trabecular geometries typical of mammalian and avian bone, whereas EF clearly detects birds' more plate-like trabeculae. EF is free from confounding relationships with BV/TV and CF. SMI results reported in the literature should be treated with suspicion. We propose that EF should be used instead of SMI for measurements of rods and plates in trabecular bone

    Beta-2-transferrin to detect cerebrospinal fluid pleural effusion: a case report

    Get PDF
    Abstract Introduction Pleural effusion secondary to ventriculoperitoneal shunt insertion is a rare and potentially life-threatening occurrence. Case presentation We describe a 14-month-old Caucasian boy who had a ventriculoperitoneal shunt inserted for progressive hydrocephalus of unknown etiology. Two and a half months post-shunt insertion, the patient presented with mild respiratory distress. A chest radiograph revealed a large right pleural effusion and a shunt series demonstrated an appropriately placed distal catheter tip. A subsequent abdominal ultrasound revealed marked ascites. Fluid drained via tube thoracostomy was sent for beta-2-transferrin electrophoresis. A positive test was highly suggestive of cerebral spinal fluid hydrothorax. Post-externalization of the ventriculoperitoneal shunt, the ascites and pleural effusion resolved. Conclusion Testing for beta-2-transferrin protein in pleural fluid may serve as a useful technique for diagnosing cerebrospinal fluid hydrothorax in patients with ventriculoperitoneal shunts

    Cancellous bone and theropod dinosaur locomotion. Part I—an examination of cancellous bone architecture in the hindlimb bones of theropods

    Get PDF
    This paper is the first of a three-part series that investigates the architecture of cancellous (‘spongy’) bone in the main hindlimb bones of theropod dinosaurs, and uses cancellous bone architectural patterns to infer locomotor biomechanics in extinct non-avian species. Cancellous bone is widely known to be highly sensitive to its mechanical environment, and has previously been used to infer locomotor biomechanics in extinct tetrapod vertebrates, especially primates. Despite great promise, cancellous bone architecture has remained little utilized for investigating locomotion in many other extinct vertebrate groups, such as dinosaurs. Documentation and quantification of architectural patterns across a whole bone, and across multiple bones, can provide much information on cancellous bone architectural patterns and variation across species. Additionally, this also lends itself to analysis of the musculoskeletal biomechanical factors involved in a direct, mechanistic fashion. On this premise, computed tomographic and image analysis techniques were used to describe and analyse the three-dimensional architecture of cancellous bone in the main hindlimb bones of theropod dinosaurs for the first time. A comprehensive survey across many extant and extinct species is produced, identifying several patterns of similarity and contrast between groups. For instance, more stemward non-avian theropods (e.g. ceratosaurs and tyrannosaurids) exhibit cancellous bone architectures more comparable to that present in humans, whereas species more closely related to birds (e.g. paravians) exhibit architectural patterns bearing greater similarity to those of extant birds. Many of the observed patterns may be linked to particular aspects of locomotor biomechanics, such as the degree of hip or knee flexion during stance and gait. A further important observation is the abundance of markedly oblique trabeculae in the diaphyses of the femur and tibia of birds, which in large species produces spiralling patterns along the endosteal surface. Not only do these observations provide new insight into theropod anatomy and behaviour, they also provide the foundation for mechanistic testing of locomotor hypotheses via musculoskeletal biomechanical modelling

    Fluid lavage in patients with open fracture wounds (FLOW): an international survey of 984 surgeons

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Although surgeons acknowledge the importance of irrigating open fracture wounds, the choice of irrigating fluid and delivery pressure remains controversial. Our objective was to clarify current opinion with regard to the irrigation of open fracture wounds.</p> <p>Methods</p> <p>We used a cross-sectional survey and a sample-to-redundancy strategy to examine surgeons' preferences in the initial management of open fracture wounds. We mailed this survey to members of the Canadian Orthopaedic Association and delivered it to attendees of an international fracture course (AO, Davos, Switzerland).</p> <p>Results</p> <p>Of the 1,764 surgeons who received the questionnaire, 984 (55.8%) responded. In the management of open wounds, the majority of surgeons surveyed, 676 (70.5%), favoured normal saline alone. Bacitracin solution was used routinely by only 161 surgeons (16.8%). The majority of surgeons, 695 (71%) used low pressures when delivering the irrigating solution to the wound. There was, however considerable variation in what pressures constituted high versus low pressure lavage. The overwhelming majority of surgeons, 889 (94.2%), reported they would change their practice if a large randomized controlled trial showed a clear benefit of an irrigating solution – especially if it was different from the solution they used.</p> <p>Conclusion</p> <p>The majority of surgeons favour both normal saline and low pressure lavage for the initial management of open fracture wounds. However, opinions varied as regards the comparative efficacy of different solutions, the use of additives and high versus low pressure. Surgeons have expressed considerable support for a trial evaluating both irrigating solutions and pressures.</p
    corecore